Comparison of coronary thermodilution and Doppler velocity for assessing coronary flow reserve

被引:105
作者
Fearon, WF
Farouque, HMO
Balsam, LB
Cooke, DT
Robbins, RC
Fitzgerald, PJ
Yeung, AC
Yock, PG
机构
[1] Stanford Univ, Med Ctr, Div Cardiovasc Med, Stanford, CA 94305 USA
[2] Stanford Univ, Med Ctr, Div Cardiothorac Surg, Stanford, CA 94305 USA
关键词
blood flow; coronary disease; microcirculation; pressure;
D O I
10.1161/01.CIR.0000099521.31396.9D
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Thermodilution coronary flow reserve (CFRthermo) is a new technique for invasively measuring coronary flow reserve (CFR) with a coronary pressure wire and is based on the ability of the pressure transducer to also measure temperature changes. Whether CFRthermo correlates well enough with absolute flow-derived CFR (CFRflow) to replace Doppler wire-derived CFR (CFRDoppler) remains unclear. Methods and Results-In an open-chest pig model, CFRthermo was measured in the left anterior descending (LAD) artery and compared with CFRDoppler and CFRflow, measured with an external flow probe placed around the LAD. In 9 pigs, CFR was measured simultaneously by all 3 means in the normal LAD and after creation of an epicardial LAD stenosis. To determine the added effect of microvascular disease, measurements of flow reserve were also performed after disruption of the coronary microcirculation with embolized microspheres. Intracoronary papaverine (20 mg) was used to induce hyperemia. In a total of 61 paired measurements, CFRthermo correlated strongly with the reference standard CFRflow (r=0.85, P<0.001). CFRDoppler correlated less well with CFRflow (r=0.72, P<0.001). Bland-Altman analysis showed a closer agreement between CFRthermo and CFRflow. Conclusion-CFRthermo correlates better with CFRflow than does CFRDoppler.
引用
收藏
页码:2198 / 2200
页数:3
相关论文
共 15 条
[1]   EVALUATION OF A TRANSIT-TIME SYSTEM FOR THE CHRONIC MEASUREMENT OF BLOOD-FLOW IN CONSCIOUS SHEEP [J].
BEDNARIK, JA ;
MAY, CN .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 78 (02) :524-530
[2]   Fractional flow reserve, absolute and relative coronary blood mow velocity reserve in relation to the results of technetium-99m sestamibi single-photon emission computed tomography in patients with two-vessel coronary artery disease [J].
Chamuleau, SAJ ;
Meuwissen, M ;
van Eck-Smit, BLF ;
Koch, KT ;
de Jong, A ;
de Winter, RJ ;
Schotborgh, CE ;
Bax, M ;
Verberne, HJ ;
Tijssen, JGP ;
Piek, JJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (05) :1316-1322
[3]   Usefulness of fractional flow reserve for risk stratification of patients with multivessel coronary artery disease and an intermediate stenosis [J].
Chamuleau, SAJ ;
Meuwissen, M ;
Koch, KT ;
van Eck-Smit, BLF ;
Tio, RA ;
Tijssen, JGP ;
Piek, JJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (04) :377-380
[4]   Coronary thermodilution to assess flow reserve - Experimental validation [J].
De Bruyne, B ;
Pijls, NHJ ;
Smith, L ;
Wievegg, M ;
Heyndrickx, GR .
CIRCULATION, 2001, 104 (17) :2003-2006
[5]   VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY [J].
DOUCETTE, JW ;
CORL, PD ;
PAYNE, HM ;
FLYNN, AE ;
GOTO, M ;
NASSI, M ;
SEGAL, J .
CIRCULATION, 1992, 85 (05) :1899-1911
[6]   Use of fractional myocardial flow reserve to assess the functional significance of intermediate coronary stenoses [J].
Fearon, WF ;
Takagi, A ;
Jeremias, A ;
Yeung, AC ;
Joye, JD ;
Cohen, DJ ;
Chou, TM ;
Kern, MJ ;
Yock, PG .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (09) :1013-1014
[7]   Simultaneous assessment of fractional and coronary flow reserves in cardiac transplant recipients - Physiologic investigation for transplant arteriopathy (PITA study) [J].
Fearon, WF ;
Nakamura, M ;
Lee, DP ;
Rezaee, M ;
Vagelos, RH ;
Hunt, SA ;
Fitzgerald, PJ ;
Yock, PG ;
Yeung, AC .
CIRCULATION, 2003, 108 (13) :1605-1610
[8]   Fractional flow reserve compared with intravascular ultrasound guidance for optimizing stent deployment [J].
Fearon, WF ;
Luna, J ;
Samady, H ;
Powers, ER ;
Feldman, T ;
Dib, N ;
Tuzcu, EM ;
Cleman, MW ;
Chou, TM ;
Cohen, DJ ;
Ragosta, M ;
Takagi, A ;
Jeremias, A ;
Fitzgerald, PJ ;
Yeung, AC ;
Kern, MJ ;
Yock, PG .
CIRCULATION, 2001, 104 (16) :1917-1922
[9]   Reproducibility of intravascular ultrasound and intracoronary Doppler measurements [J].
Gaster, AL ;
Korsholm, L ;
Thayssen, P ;
Pedersen, KE ;
Haghfelt, TH .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 53 (04) :449-458
[10]   Coronary physiology revisited - Practical insights from the cardiac catheterization laboratory [J].
Kern, MJ .
CIRCULATION, 2000, 101 (11) :1344-1351