Characterization and identification of spatial artifacts during 4D-CT imaging

被引:30
作者
Han, Dongfeng [1 ]
Bayouth, John [1 ]
Bhatia, Sudershan [1 ]
Sonka, Milan [1 ,2 ]
Wu, Xiaodong [1 ,2 ]
机构
[1] Univ Iowa Hosp & Clin, Div Med Phys, Dept Radiat Oncol, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Elect & Comp Engn, Iowa City, IA 52242 USA
基金
美国国家科学基金会;
关键词
4D-CT; artifacts; normalized cross correlation convolution; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; MULTISLICE HELICAL CT; DEFORMABLE REGISTRATION; RESPIRATORY MOTION; AUDIOVISUAL BIOFEEDBACK; RADIATION-THERAPY; SORTING ALGORITHM; TUMOR MOTION; LUNG; RADIOTHERAPY;
D O I
10.1118/1.3553556
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: The purpose of this work is twofold: First, to characterize the artifacts occurring in helical 4D-CT imaging; second, to propose a method that can automatically identify the artifacts in 4D-CT images. The authors have designed a process that can automatically identify the artifacts in 4D-CT images, which may be invaluable in quantifying the quality of 4D-CT images and reducing the artifacts from the reconstructed images on a large dataset. Methods: Given two adjacent stacks obtained from the same respiration phase, the authors determine if there are artifacts between them. The proposed method uses a "bridge" stack strategy to connect the two stacks. Using normalized cross correlation convolution (NCCC), the two stacks are mapped to the bridge stack and the best matching positions can be located. Using this position information, the authors can then determine if there are artifacts between the two stacks. By combining the matching positions with NCCC values, the performance can be improved. Results: To validate the method, three expert observers independently labeled over 600 stacks on five patients. The results confirmed that high performance was obtained using the proposed method. The average sensitivity was about 0.87 and the average specificity was 0.82. The proposed method also outperformed the method of using respiratory signal (sensitivity increased from 0.50 to 0.87 and specificity increased from 0.70 to 0.82). Conclusions: This study shows that the spatial artifacts during 4D-CT imaging are characterized and can be located automatically by the proposed method. The method is relatively simple but effective. It provides a way to evaluate the artifacts more objectively and accurately. The reported approach has promising potential for automatically identifying the types and frequency of artifacts on large scale 4D-CT image dataset. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3553556]
引用
收藏
页码:2074 / 2087
页数:14
相关论文
共 49 条
[1]
Phase and amplitude binning for 4D-CT imaging [J].
Abdelnour, A. F. ;
Nehmeh, S. A. ;
Pan, T. ;
Humm, J. L. ;
Vernon, P. ;
Schoder, H. ;
Rosenzweig, K. E. ;
Mageras, G. S. ;
Yorke, E. ;
Larson, S. M. ;
Erdi, Y. E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (12) :3515-3529
[2]
4D-CT lung motion estimation with deformable registration: Quantification of motion nonlinearity and hysteresis [J].
Boldea, Vlad ;
Sharp, Gregory C. ;
Jiang, Steve B. ;
Sarrut, David .
MEDICAL PHYSICS, 2008, 35 (03) :1008-1018
[3]
A fully automated non-external marker 4D-CT sorting algorithm using a serial cine scanning protocol [J].
Carnes, Greg ;
Gaede, Stewart ;
Yu, Edward ;
Van Dyk, Jake ;
Battista, Jerry ;
Lee, Ting-Yim .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07) :2049-2066
[4]
Planning lung radiotherapy using 4D CT data and a motion model [J].
Colgan, R. ;
McClelland, J. ;
McQuaid, D. ;
Evans, P. M. ;
Hawkes, D. ;
Brock, J. ;
Landau, D. ;
Webb, S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (20) :5815-5830
[5]
Image reconstruction [J].
Defrise, Michel ;
Gullberg, Grant T. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (13) :R139-R154
[6]
Four-dimensional multislice helical CT of the lung: Qualitative comparison of retrospectively gated and static images in an ex-vivo system [J].
Dinkel, Julien ;
Welzel, Thomas ;
Bolte, Hendrik ;
Hoffmann, Beata ;
Thierfelder, Carsten ;
Mende, Ulrich ;
Debus, Juergen ;
Heller, Martin ;
Kauczor, Hans-Utrich ;
Biederer, Juergen .
RADIOTHERAPY AND ONCOLOGY, 2007, 85 (02) :215-222
[7]
An optical flow based method for improved reconstruction of 4D CT data sets acquired during free breathing [J].
Ehrhardt, Jan ;
Werner, Rene ;
Saering, Dennis ;
Frenzel, Thorsten ;
Lu, Wei ;
Low, Daniel ;
Handels, Heinz .
MEDICAL PHYSICS, 2007, 34 (02) :711-721
[8]
Automated breathing motion tracking for 4D computed tomography [J].
El Naqa, I ;
Low, DA ;
Deasy, JO ;
Amini, A ;
Parikh, P ;
Nystrom, M .
2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, :3219-3222
[9]
Endo Masahiro, 2003, Radiat Med, V21, P17
[10]
Displacement-based binning of time-dependent computed tomography image data sets [J].
Fitzpatrick, MJ ;
Starkschall, G ;
Antolak, JA ;
Fu, J ;
Shukla, H ;
Keall, PJ ;
Klahr, P ;
Mohan, R .
MEDICAL PHYSICS, 2006, 33 (01) :235-246