Phase and amplitude binning for 4D-CT imaging

被引:115
作者
Abdelnour, A. F. [1 ]
Nehmeh, S. A.
Pan, T.
Humm, J. L.
Vernon, P.
Schoder, H.
Rosenzweig, K. E.
Mageras, G. S.
Yorke, E.
Larson, S. M.
Erdi, Y. E.
机构
[1] US Patent & Trademark Off, Alexandria, VA USA
[2] Mem Sloan Kettering Canc Ctr, New York, NY 10021 USA
[3] MD Anderson Canc Ctr, Houston, TX USA
[4] GE Healthcare Technol, Waukesha, WI USA
关键词
D O I
10.1088/0031-9155/52/12/012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We compare the consistency and accuracy of two image binning approaches used in 4D-CT imaging. One approach, phase binning (PB), assigns each breathing cycle 2 pi rad, within which the images are grouped. In amplitude binning ( AB), the images are assigned bins according to the breathing signal's full amplitude. To quantitate both approaches we used a NEMA NU2-2001 IEC phantom oscillating in the axial direction and at random frequencies and amplitudes, approximately simulating a patient's breathing. 4D-CT images were obtained using a four-slice GE Lightspeed CT scanner operating in cine mode. We define consistency error as a measure of ability to correctly bin over repeated cycles in the same field of view. Average consistency error mu(e) +/- sigma(e) in PB ranged from 18% 20% to 30% 35%, while in AB the error ranged from 11% +/- 14% to 20% +/- 24%. In PB nearly all bins contained sphere slices. AB was more accurate, revealing empty bins where no sphere slices existed. As a proof of principle, we present examples of two non- small cell lung carcinoma patients' 4D-CT lung images binned by both approaches. While AB can lead to gaps in the coronal images, depending on the patient's breathing pattern, PB exhibits no gaps but suffers visible artifacts due to misbinning, yielding images that cover a relatively large amplitude range. AB was more consistent, though often resulted in gaps when no data existed due to patients' breathing pattern. We conclude AB is more accurate than PB. This has important consequences to treatment planning and diagnosis.
引用
收藏
页码:3515 / 3529
页数:15
相关论文
共 25 条
[1]  
[Anonymous], 2001, ESSENTIAL PHYS MED I
[2]   Disocclusion by joint interpolation of vector fields and gray levels [J].
Ballester, C ;
Caselles, V ;
Verdera, J .
MULTISCALE MODELING & SIMULATION, 2003, 2 (01) :80-123
[3]   Artifacts in computed tomography scanning of moving objects [J].
Chen, GTY ;
Kung, JH ;
Beaudette, KP .
SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) :19-26
[4]  
ELNAQA I, 2003, C REC IEEE NUCL SCI, V5, P3219
[5]  
Endo Masahiro, 2003, Radiat Med, V21, P17
[6]  
Gallant G A, 1997, Med Dosim, V22, P23, DOI 10.1016/S0958-3947(96)00150-1
[7]  
Giraud P, 2004, Rev Pneumol Clin, V60, P22, DOI 10.1016/S0761-8417(04)72079-9
[8]  
Giraud P, 2005, B CANCER, V92, P83
[9]   4-dimensional computed tomography imaging and treatment planning [J].
Keall, P .
SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) :81-90
[10]  
Kini Vijay R, 2003, Med Dosim, V28, P7, DOI 10.1016/S0958-3947(02)00136-X