Nanoliter solvent extraction combined with microspot MALDI TOF mass spectrometry for the analysis of hydrophobic biomolecules

被引:31
作者
Keller, BO [1 ]
Li, L [1 ]
机构
[1] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
关键词
D O I
10.1021/ac001323g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A nanoliter solvent extraction technique combined with microspot matrix-assisted laser desorption/ionization (MALDI) mass spectrometry is presented. This method involves the use of a nanoliter droplet containing organic solvents at the tip of a small capillary for extraction. The droplet is formed inside a microliter aqueous sample containing the analyte of interest. After extraction, the droplet is deposited onto a MALDI target precoated with a thin matrix layer. Since the nanoliter droplet never touches the sample container wall, any possible extraction of contaminants adsorbed on the plastic or glassware is avoided. In addition, there is no need to concentrate the organic phase after the extraction, thus avoiding any possible loss during the concentration step. The nanoliter volume can be readily deposited onto a MALDI target, producing a high analyte concentration within a microspot, Combined with microspot MALDI, this technique allows for very sensitive analysis of the extracted analyte, The performance of this technique is illustrated in several applications involving the detection of hydrophobic peptides or phospholipids, It is shown that very hydrophobic analytes can be extracted from small-volume samples containing a large amount of salts and/or more hydrophilic analytes, which tend to give dominant signals in conventional MALDI experiments. Nanoliter extraction of analyte from samples containing less than 100 nM hydrophobic analyte and over 1 muM easily ionized hydrophilic species is demonstrated. Finally, using the analysis of the ionophore valinomycin as an example, it is demonstrated that the technique is a more reliable tool for probing metal-peptide complexes than regular MALDI sample preparations.
引用
收藏
页码:2929 / 2936
页数:8
相关论文
共 48 条
[1]  
ALBERTS B, 1994, MOL BIOL CELL, P511
[2]  
Amado FML, 1997, RAPID COMMUN MASS SP, V11, P1347, DOI 10.1002/(SICI)1097-0231(199708)11:12<1347::AID-RCM974>3.0.CO
[3]  
2-8
[4]   Surfactant-aided, matrix assisted laser desorption/ionization mass spectrometry of hydrophobic and hydrophilic peptides [J].
Breaux, GA ;
Green-Church, KB ;
France, A ;
Limbach, PA .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1169-1174
[5]   A robust, detergent-friendly method for mass spectrometric analysis of integral membrane proteins [J].
Cadene, M ;
Chait, BT .
ANALYTICAL CHEMISTRY, 2000, 72 (22) :5655-5658
[6]   Confocal fluorescence microscopic imaging for investigating the analyte distribution in MALDI matrices [J].
Dai, YQ ;
Whittal, RM ;
Li, L .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2494-2500
[7]   Two-layer sample preparation: A method for MALDI-MS analysis of complex peptide and protein mixtures [J].
Dai, YQ ;
Whittal, RM ;
Li, L .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :1087-1091
[8]   BINDING OF THE IMMUNOSUPPRESSANT PEPTIDE CYCLOSPORINE-A TO CALCIUM, ZINC AND COPPER - IS CYCLOSPORINE-A AN IONOPHORE [J].
DANCER, RJ ;
JONES, A ;
FAIRLIE, DP .
AUSTRALIAN JOURNAL OF CHEMISTRY, 1995, 48 (11) :1835-1841
[9]  
FRANCIS AW, 1972, HDB COMPONENTS SOLVE
[10]  
Goswami R, 2000, J NEUROSCI RES, V60, P141, DOI 10.1002/(SICI)1097-4547(20000415)60:2<141::AID-JNR2>3.0.CO