Improved stability and altered selectivity of tyrosinase based graphite electrodes for detection of phenolic compounds

被引:162
作者
Nistor, C
Emnéus, J
Gorton, L
Ciucu, A
机构
[1] Univ Lund, Dept Analyt Chem, S-22100 Lund, Sweden
[2] Univ Bucharest, Fac Chem, Dept Analyt Chem, Bucharest, Romania
关键词
tyrosinase; carbon paste electrode; biosensor; Nafion; Eastman AQ; phenols; catechol; waste water; operational and storage stability; selectivity;
D O I
10.1016/S0003-2670(99)00071-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The operational and storage stability of tyrosinase biosensors were investigated for different tyrosinase modified electrodes, i.e., plain bulk modified carbon paste electrodes (CPEs), surface modified by simple adsorption to solid graphite electrodes (SGEs), and surface modified by the immobilisation in Eastman AQ, a poly ester-sulphonic acid cation exchanger, and Nafion, a perfluorinated-sulphonated ionomer, on the surface of both CP and SGEs, Factors such as the pH of immobilisation, the enzyme loading, and the polymer concentration were investigated in regards to the influence on the sensitivity, the limit of detection (LOD), the sample throughput (STP), and the operational and storage stability. Both storage and operational stability were improved by immobilisation of tyrosinase in either of the two polymer matrices. For 50 consecutive injections of 50 mu M catechol, the response stayed the same for the optimal Eastman and Nafion modified CP and SGEs. After about 42 days 80% and 75% of the original response for the Eastman and Nafion modified tyrosinase electrodes remained, respectively, whereas the tyrosinase bulk-modified CPE and adsorbed tyrosinase SGEs had lost virtually 100% of the original response. The selectivity for nine phenolic compounds were investigated and found to change with the introduction of the polymer membrane. The detection of especially monophenols was improved probably due to their preconcentration into the polymer membranes. The best performing biosensor in terms of sensitivity, LOD, STP, operational and storage stability was reached for one where tyrosinase was immobilised in Nafion, i.e., sensitivity: 11.51 nA/mu M, LOD: 0.015 mu M catechol, and STP: 36 samples/h. The phenolic content, expressed as catechol equivalents was evaluated in six waste water effluents from tannery industries in Spain and Sweden. The operational stability after 90 consecutive injections of extremely contaminated waste waters showed that the Nafion sensor retained 70% of its initial response. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:309 / 326
页数:18
相关论文
共 61 条
[1]  
[Anonymous], 1992, ENZYME NOMENCLATURE
[2]   ENZYMATIC DETERMINATION OF GLUCOSE IN A FLOW SYSTEM BY CATALYTIC-OXIDATION OF THE NICOTINAMIDE COENZYME AT A MODIFIED ELECTRODE [J].
APPELQVIST, R ;
MARKOVARGA, G ;
GORTON, L ;
TORSTENSSON, A ;
JOHANSSON, G .
ANALYTICA CHIMICA ACTA, 1985, 169 (MAR) :237-247
[3]  
BARCELO D, 1993, ENV ANAL TECHNIQUES
[4]   SEPARATION OF PHENOLS BY PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
BERGER, TA ;
DEYE, JF .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (02) :54-59
[5]   BIOAMPEROMETRIC SENSORS FOR PHENOL BASED ON CARBON PASTE ELECTRODES [J].
BONAKDAR, M ;
VILCHEZ, JL ;
MOTTOLA, HA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 266 (01) :47-55
[6]   ULTRAVIOLET SPECTROPHOTOMETRIC DETERMINATION OF PHENOLS IN NATURAL AND WASTE-WATERS WITH IODINE MONOBROMIDE [J].
BOSCH, F ;
FONT, G ;
MANES, J .
ANALYST, 1987, 112 (09) :1335-1337
[7]   SEPARATION OF PHENOLS AND AROMATIC-HYDROCARBONS FROM BIOMASS TAR USING AMINOPROPYLSILANE NORMAL-PHASE LIQUID-CHROMATOGRAPHY [J].
BRAGE, C ;
SJOSTROM, K .
JOURNAL OF CHROMATOGRAPHY, 1991, 538 (02) :303-310
[8]   AN AMPEROMETRIC GLUCOSE ELECTRODE BASED ON CARBON PASTE, CHEMICALLY MODIFIED WITH GLUCOSE-DEHYDROGENASE, NICOTINAMIDE ADENINE-DINUCLEOTIDE, AND A PHENOXAZINE MEDIATOR, COATED WITH A POLY(ESTER SULFONIC-ACID) CATION EXCHANGER [J].
BREMLE, G ;
PERSSON, B ;
GORTON, L .
ELECTROANALYSIS, 1991, 3 (02) :77-86
[9]  
BRODFUEHRER JI, 1990, DRUG METAB DISPOS, V18, P20
[10]   Rate-limiting steps of tyrosinase-modified electrodes for the detection of catechol [J].
Burestedt, E ;
Narvaez, A ;
Ruzgas, T ;
Gorton, L ;
Emneus, J ;
Dominguez, E ;
MarkoVarga, G .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1605-1611