Contrast-enhanced coronary artery imaging using 3D trueFISP

被引:17
作者
Deshpande, VS
Li, DB
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
关键词
magnetic resonance imaging (MRI); fast imaging; steady-state free precession (SSFP); MR angiography; coronary arteries; contrast-enhanced imaging;
D O I
10.1002/mrm.10554
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An ECG-triggered, segmented, magnetization-prepared, 3D, trueFISP sequence was recently developed for coronary artery imaging. Fat saturation was achieved by a chemically selective fat saturation pulse, which is susceptible to field inhomogeneities. In addition, the blood-myocardial contrast was compromised because data were acquired during signal transience to steady state. The goals of this work were to investigate the potential benefits of T-1-shortening agents in improving blood-myocardial contrast, and to develop a technique to make fat suppression robust to resonance offsets for coronary artery imaging using trueFISP. A magnetization-preparation scheme using saturation and inversion pulses was developed for simultaneous suppression of tissues over a wide range of T-1's, including myocardium and fat. An additional advantage of this method is that it is insensitive to heart rate variations. Computer simulations were used to design the magnetization preparation, and volunteer studies were performed to compare precontrast imaging to contrast-enhanced (CE) imaging. Results showed consistent fat suppression and a 78% increase in the blood-myocardial contrast-to-noise ratio (CNR) for postcontrast imaging over precontrast imaging. In conclusion, contrast agents are useful for trueFISP coronary artery imaging. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:570 / 577
页数:8
相关论文
共 14 条
[1]   Reduction of transient signal oscillations in True-FISP using a linear flip angle series magnetization preparation [J].
Deshpande, VS ;
Chung, YC ;
Zhang, Q ;
Shea, SM ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) :151-157
[2]   3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries [J].
Deshpande, VS ;
Shea, SM ;
Laub, G ;
Simonetti, OP ;
Finn, JP ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :494-502
[3]   MULTIPLE INVERSION RECOVERY REDUCES STATIC TISSUE SIGNAL IN ANGIOGRAMS [J].
DIXON, WT ;
SARDASHTI, M ;
CASTILLO, M ;
STOMP, GP .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :257-268
[4]   Coronary arteries: Breath-hold, gadolinium-enhanced, three-dimensional MR angiography [J].
Goldfarb, JW ;
Edelman, RR .
RADIOLOGY, 1998, 206 (03) :830-834
[5]   MEASUREMENT OF SIGNAL INTENSITIES IN THE PRESENCE OF NOISE IN MR IMAGES [J].
HENKELMAN, RM .
MEDICAL PHYSICS, 1985, 12 (02) :232-233
[6]   MR IMAGING OF FLOW USING THE STEADY-STATE SELECTIVE SATURATION METHOD [J].
HENNIG, J ;
MUERI, M ;
FRIEDBURG, H ;
BRUNNER, P .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) :872-877
[7]   Coronary arteries: Magnetization-prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography [J].
Li, DB ;
Carr, JC ;
Shea, SM ;
Zheng, J ;
Deshpande, VS ;
Wielopolski, PA ;
Finn, JP .
RADIOLOGY, 2001, 219 (01) :270-277
[8]   Background suppression with multiple inversion recovery nulling: Applications to projective angiography [J].
Mani, S ;
Pauly, J ;
Conolly, S ;
Meyer, C ;
Nishimura, D .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (06) :898-905
[9]  
NISHIMURA DG, 2000, P 8 ANN M ISMRM DENV, P301
[10]   Three-dimensional coronary magnetic resonance angiography with injection of extracellular contrast medium [J].
Sakuma, H ;
Goto, M ;
Nomura, Y ;
Kato, N ;
Takeda, K ;
Higgins, CB .
INVESTIGATIVE RADIOLOGY, 1999, 34 (08) :503-508