Regional ventilation by electrical impedance tomography - A comparison with ventilation scintigraphy in pigs

被引:130
作者
Hinz, J
Neumann, P
Dudykevych, T
Andersson, LG
Wrigge, H
Burchardi, H
Hedenstierna, G
机构
[1] Univ Gottingen, Dept Anesthesiol Emergency & Intens Care Med, D-37075 Gottingen, Germany
[2] Uppsala Univ, Dept Clin Physiol, Uppsala, Sweden
[3] Univ Bonn, Dept Anesthesiol & Intens Care Med, D-5300 Bonn, Germany
关键词
regional ventilation; thoracic electrical impedance tomography;
D O I
10.1378/chest.124.1.314
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: The validation of electrical impedance tomography (EIT) for measuring regional ventilation distribution by comparing it with single photon emission CT (SPECT) scanning. Design: Randomized, prospective animal study. Settings: Animal laboratories and nuclear medicine laboratories at a university hospital. Participants: Twelve anesthetized and mechanically ventilated pigs. Interventions: Lung injury was induced by central venous injection of oleic acid. Then pigs were randomized to pressure-controlled mechanical ventilation, airway pressure-release ventilation, or spontaneous breathing. Measurements and results: Ventilation distribution was assessed by EIT using cross-sectional electrotomographic measurements of the thorax, and simultaneously by single SPECT scanning with the inhalation of Tc-99m-labeled carbon particles. For both methods, the evaluation of ventilation distribution was performed in the same transverse slice that was approximately 4 cm in thickness. The transverse slice then was divided into 20 coronal segments (going from the sternum to the spine). We compared the percentage of ventilation in each segment, normalized to the entire ventilation in the observed slice. Our data showed an excellent linear correlation between the ventilation distribution measured by SPECT scanning and EIT according to the following equation: y = 0.82x + 0.7,(R-2 = 0.92; range, 0.86 to 0.97). Conclusion: Based on these data, EIT seems to allow, at least in comparable states of lung injury, real-time monitoring of regional ventilation distribution at the bedside.
引用
收藏
页码:314 / 322
页数:9
相关论文
共 32 条
[1]   Electrical impedance tomography can monitor dynamic hyperinflation in dogs [J].
Adler, A ;
Shinozuka, N ;
Berthiaume, Y ;
Guardo, R ;
Bates, JHT .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 84 (02) :726-732
[2]   Monitoring changes in lung air and liquid volumes with electrical impedance tomography [J].
Adler, A ;
Amyot, R ;
Guardo, R ;
Bates, JHT ;
Berthiaume, Y .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (05) :1762-1767
[3]  
Barber D C, 1986, P 9 C INF PROC MED I, P106
[4]   APPLIED POTENTIAL TOMOGRAPHY [J].
BARBER, DC ;
BROWN, BH .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1984, 17 (09) :723-733
[5]   QUANTIFICATION IN IMPEDANCE IMAGING [J].
BARBER, DC .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1990, 11 :45-56
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]  
Brown B H, 1987, Clin Phys Physiol Meas, V8 Suppl A, P91, DOI 10.1088/0143-0815/8/4A/012
[8]  
BURCH WM, 1986, J NUCL MED, V27, P842
[9]   Gravity-dependent phenomena in lung ventilation determined by functional EIT [J].
Frerichs, I ;
Hahn, G ;
Hellige, G .
PHYSIOLOGICAL MEASUREMENT, 1996, 17 :A149-A157
[10]   Thoracic electrical impedance tomographic measurements during volume controlled ventilation-effects of tidal volume and positive end-expiratory pressure [J].
Frerichs, I ;
Hahn, G ;
Hellige, G .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (09) :764-773