摘要
Purpose: Vena cava filter (VCF) application is the method of choice to prevent recurrent pulmonary embolism in patients with deep venous thrombosis. Because of the reported complications after VCF placement we summarize our long-term follow-up results with the LGM and Titanium Greenfield (TG) devices. Methods: Eighty-seven LGM VCF and 17 TG VCF were placed in 104 patients (average age 64 years). The follow-up examinations were performed by color-coded duplex sonography, plain radiographs, cavography, and computed tomography (CT). The maximum observation time was 81 months. Results: Filter migration occurred in 11% (8/76) of the LGM VCF and 15% (2/13) of the TG VCF. Vena cava thrombosis was seen in 17% (13/76) of the patients with an LGM VCF and in 31% (4/13) of those with a TG VCF. The patency rate was 95% (72/76) for the LGM VCF and 92% (12/13) for the TG VCF. Pulmonary embolism was noted in 3 patients after LGM VCF insertion and in no patient after TG VCF insertion. Conclusion: A VCF should only be inserted in a patient after pulmonary embolism and when there is strict proof of the indication.
引用
收藏
页码:225 / 229
页数:5
相关论文
共 30 条
[21]   PERCUTANEOUS INSERTION OF THE GREENFIELD FILTER [J].
PAIS, SO ;
TOBIN, KD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (05) :933-938
[22]  
RICCO JB, 1988, ANN VASC SURG, V3, P242
[23]   MIGRATION OF A VENA-CAVAL FILTER TO THE PULMONARY-ARTERY [J].
RITCHIE, AJ ;
MITCHELL, L ;
FORTY, J .
BRITISH JOURNAL OF SURGERY, 1995, 82 (02) :207-207
[24]   PERCUTANEOUS TRANS-FEMORAL PLACEMENT OF THE KIMRAY-GREENFIELD VENA-CAVA FILTER [J].
ROSE, BS ;
SIMON, DC ;
HESS, ML ;
VANAMAN, ME .
RADIOLOGY, 1987, 165 (02) :373-376
[25]   COMPARATIVE-EVALUATION OF CLINICALLY AVAILABLE INFERIOR VENA-CAVA FILTERS WITH AN IN-VITRO PHYSIOLOGICAL SIMULATION OF THE VENA-CAVA [J].
SIMON, M ;
RABKIN, DJ ;
KLESHINSKI, S ;
KIM, D ;
RANSIL, BJ .
RADIOLOGY, 1993, 189 (03) :769-774
[26]  
Taylor F C, 1991, J Vasc Interv Radiol, V2, P435, DOI 10.1016/S1051-0443(91)72214-8
[27]   RECURRENT PULMONARY-EMBOLISM IN CASE OF DYSFUNCTION OF AN LGM CAVA FILTER FOLLOWING RECHANNELLING OF A CAVA THROMBOSIS [J].
TSCHAMMLER, A ;
MARKERT, T ;
WITTENBERG, G ;
KRAHE, T .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 161 (01) :83-84
[28]  
Vorwerk D, 1987, Rofo, V146, P558, DOI 10.1055/s-2008-1048540
[29]   LGM CAVA FILTER EXPERIENCES WITH LEFT-TRANSFEMORAL APPLICATION [J].
WITTENBERG, G ;
KRAHE, T ;
TSCHAMMLER, A ;
HAHN, D .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 161 (05) :456-458