Monitoring of Brain and Systemic Oxygenation in Neurocritical Care Patients

被引:76
作者
Oddo, Mauro [1 ]
Bosel, Julian [2 ]
机构
[1] CHUV Lausanne Univ Hosp, Fac Biol & Med, Dept Intens Care Med, CH-1011 Lausanne, Switzerland
[2] Heidelberg Univ, Neurocrit Care Sect, Dept Neurol, D-69120 Heidelberg, Germany
关键词
Brain oxygen; Jugular oxygen saturation; Near-infrared spectroscopy; Carbon dioxide; Systemic oxygenation; Neurocritical care; NEAR-INFRARED SPECTROSCOPY; CEREBRAL PERFUSION-PRESSURE; SEVERE HEAD-INJURY; ANEURYSMAL SUBARACHNOID HEMORRHAGE; JUGULAR BULB OXIMETRY; IMPAIRED CEREBROVASCULAR AUTOREGULATION; POSITRON-EMISSION-TOMOGRAPHY; END-EXPIRATORY PRESSURE; ACUTE ISCHEMIC-STROKE; WAKE-UP TEST;
D O I
10.1007/s12028-014-0024-6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Maintenance of adequate oxygenation is a mainstay of intensive care, however, recommendations on the safety, accuracy, and the potential clinical utility of invasive and non-invasive tools to monitor brain and systemic oxygenation in neurocritical care are lacking. A literature search was conducted for English language articles describing bedside brain and systemic oxygen monitoring in neurocritical care patients from 1980 to August 2013. Imaging techniques e.g., PET are not considered. A total of 281 studies were included, the majority described patients with traumatic brain injury (TBI). All tools for oxygen monitoring are safe. Parenchymal brain oxygen (PbtO(2)) monitoring is accurate to detect brain hypoxia, and it is recommended to titrate individual targets of cerebral perfusion pressure (CPP), ventilator parameters (PaCO2, PaO2), and transfusion, and to manage intracranial hypertension, in combination with ICP monitoring. SjvO(2) is less accurate than PbtO(2). Given limited data, NIRS is not recommended at present for adult patients who require neurocritical care. Systemic monitoring of oxygen (PaO2, SaO(2), SpO(2)) and CO2 (PaCO2, end-tidal CO2) is recommended in patients who require neurocritical care.
引用
收藏
页码:103 / 120
页数:18
相关论文
共 299 条
[81]   Fluid Balance, Complications, and Brain Tissue Oxygen Tension Monitoring Following Severe Traumatic Brain Injury [J].
Fletcher, Jeffrey J. ;
Bergman, Karen ;
Blostein, Paul A. ;
Kramer, Andreas H. .
NEUROCRITICAL CARE, 2010, 13 (01) :47-56
[82]   Effect of hyperventilation, mannitol, and ventriculostomy drainage on cerebral blood flow after head injury [J].
Fortune, JB ;
Feustel, PJ ;
Graca, L ;
Hasselbarth, J ;
Kuehler, DH .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1995, 39 (06) :1091-1099
[83]   CONTINUOUS MEASUREMENT OF JUGULAR VENOUS OXYGEN-SATURATION IN RESPONSE TO TRANSIENT ELEVATIONS OF BLOOD-PRESSURE IN HEAD-INJURED PATIENTS [J].
FORTUNE, JB ;
FEUSTEL, PJ ;
WEIGLE, CGM ;
POPP, AJ .
JOURNAL OF NEUROSURGERY, 1994, 80 (03) :461-468
[84]   Equimolar doses of mannitol and hypertonic saline in the treatment of increased intracranial pressure [J].
Francony, Gilles ;
Fauvage, Bertrand ;
Falcon, Dominique ;
Canet, Charles ;
Dilou, Henri ;
Lavagne, Pierre ;
Jacquot, Claude ;
Payen, Jean-Francois .
CRITICAL CARE MEDICINE, 2008, 36 (03) :795-800
[85]   POTENTIAL UTILITY OF NEAR-INFRARED SPECTROSCOPY IN OUT-OF-HOSPITAL CARDIAC ARREST: AN ILLUSTRATIVE CASE SERIES [J].
Frisch, Adam ;
Suffoletto, Brian P. ;
Frank, Rachel ;
Martin-Gill, Christian ;
Menegazzi, James J. .
PREHOSPITAL EMERGENCY CARE, 2012, 16 (04) :564-570
[86]  
Gelabert-González M, 2002, ACTA NEUROCHIR, V144, P863, DOI 10.1007/s00701-002-0975-9
[87]   EXTRACEREBRAL ABSORPTION OF NEAR-INFRARED LIGHT INFLUENCES THE DETECTION OF INCREASED CEREBRAL OXYGENATION MONITORED BY NEAR-INFRARED SPECTROSCOPY [J].
GERMON, TJ ;
YOUNG, AER ;
MANARA, AR ;
NELSON, RJ .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1995, 58 (04) :477-479
[88]   Cerebral Near-Infrared Spectroscopy in Adults: A Work in Progress [J].
Ghosh, Arnab ;
Elwell, Clare ;
Smith, Martin .
ANESTHESIA AND ANALGESIA, 2012, 115 (06) :1373-1383
[89]   JUGULAR BULB CATHETERIZATION DOES NOT INCREASE INTRACRANIAL-PRESSURE [J].
GOETTING, MG ;
PRESTON, G .
INTENSIVE CARE MEDICINE, 1991, 17 (04) :195-198
[90]   A comparison of the hamamatsu NIRO 500 and the INVOS 3100 near-infrared spectrophotometers [J].
Gomersall, CD ;
Leung, PL ;
Gin, T ;
Joynt, GM ;
Young, RJ ;
Poon, WS ;
Oh, TE .
ANAESTHESIA AND INTENSIVE CARE, 1998, 26 (05) :548-557