Techno-economic and thermodynamic analysis of pre-cooling systems at gaseous hydrogen refueling stations

被引:93
作者
Elgowainy, Amgad [1 ]
Reddi, Krishna [1 ]
Lee, Dong-Yeon [1 ]
Rustagi, Neha [2 ]
Gupta, Erika [2 ]
机构
[1] Argonne Natl Lab, 9700 South Cass Ave, Lemont, IL 60439 USA
[2] US DOE, Fuel Cell Technol Off, 1000 Independence Ave SW, Washington, DC 20585 USA
关键词
Hydrogen refueling; Pre-cooling; Refrigeration; Heat exchanger; Cost; Energy; IMPACT;
D O I
10.1016/j.ijhydene.2017.09.087
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We conducted a techno-economic and thermodynamic analysis of precooling units (PCUs) at hydrogen refueling stations and developed a cost-minimizing design algorithm for the PCU observing the SAE J2601 refueling protocol for T40 stations (requiring -40 degrees C precooling temperature). In so doing, we identified major factors that affect PCU cost and energy use. The hydrogen precooling energy intensity depends strongly on the station utilization rate, but approaches 0.3 kWh(e)/kg-H-2 at full utilization. In early fuel cell electric vehicle markets where utilization of the refueling capacity is low, the overhead cooling load (to keep the heat exchanger cold at 40 degrees C) results in significantly high PCU energy intensity because only a small amount of hydrogen is being dispensed. We developed a parameterized pre cooling energy intensity prediction formula as a function of the ambient temperature and station utilization rate. We also found that the Joule-Thomson effect of the flow control device introduces a significant increase in temperature upstream of the PCU's heat exchanger (HX), which impacts the PCU design capacity. An optimal PCU (per dispenser, at 35 degrees C HX inlet temperature) consists of a 13-kW refrigerator and a HX with 1400 kg of thermal mass (aluminum), which currently costs $70,000 (uninstalled). The total (installed) capital and operation cost of PCU at a fully utilized hydrogen refueling station adds $0.50/kg-H-2. (C) 2017 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:29067 / 29079
页数:13
相关论文
共 18 条
[1]  
[Anonymous], 2016, Electric Power Monthly
[2]  
[Anonymous], 2016, Thermophysical Properties of Fluid Systems
[3]  
Argonne (Argonne National Laboratory), 2016, HYDR DEL SCEN AN MOD
[4]  
Argonne National Laboratory, 2016, HYDR REF STAT AN MOD
[5]  
Bitzer, 2016, BITZ LOW TEMP REFR
[6]  
DOE (U.S. Depaz luient of Energy), 2014, WEB REP OUT 2 INT WO
[7]   Tube-trailer consolidation strategy for reducing hydrogen refueling station costs [J].
Elgowainy, Amgad ;
Reddi, Krishna ;
Sutherland, Erika ;
Joseck, Fred .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (35) :20197-20206
[8]   Rethinking Hydrogen Fueling Insights from Delivery Modeling [J].
Mintz, Marianne ;
Elgowainy, Amgad ;
Gardiner, Monterey .
TRANSPORTATION RESEARCH RECORD, 2009, (2139) :46-54
[9]  
National Renewable Energy Laboratory (NREL), 2014, NRELBK6A1058564
[10]  
Reddi K, 2016, WOODHEAD PUBL SER EN, P293, DOI 10.1016/B978-1-78242-364-5.00013-0