Paper-Based Electrochemical Sensing Platform with Integral Battery and Electrochromic Read-Out

被引:205
作者
Liu, Hong
Crooks, Richard M. [1 ]
机构
[1] Univ Texas Austin, Dept Chem & Biochem, Ctr Electrochem, Austin, TX 78712 USA
关键词
SENSORS; DEVICES;
D O I
10.1021/ac203457h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report a battery-powered, microelectrochemical sensing platform that reports its output using an electrochromic display. The platform is fabricated based on paper fluidics and uses a Prussian blue spot electrodeposited on an indium-doped tin oxide thin film as the electrochromic indicator. The integrated metal/air battery powers both the electrochemical sensor and the electrochromic read-out, which are in electrical contact via a paper reservoir. The sample activates the battery and the presence of analyte in the sample initiates the color change of the Prussian blue spot. The entire system is assembled on the lab bench, without the need for cleanroom facilities. The applicability of the device to point-of-care sensing is demonstrated by qualitative detection of 0.1 mM glucose and H2O2 in artificial urine samples.
引用
收藏
页码:2528 / 2532
页数:5
相关论文
共 16 条
[1]   Electrochemical Detection for Paper-Based Microfluidics [J].
Dungchai, Wijitar ;
Chailapakul, Orawon ;
Henry, Charles S. .
ANALYTICAL CHEMISTRY, 2009, 81 (14) :5821-5826
[2]   Nitroaromatic Actuation of Mitochondrial Bioelectrocatalysis for Self-Powered Explosive Sensors [J].
Germain, Marguerite N. ;
Arechederra, Robert L. ;
Minteer, Shelley D. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (46) :15272-+
[3]   Point of Care Diagnostics: Status and Future [J].
Gubala, Vladimir ;
Harris, Leanne F. ;
Ricco, Antonio J. ;
Tan, Ming X. ;
Williams, David E. .
ANALYTICAL CHEMISTRY, 2012, 84 (02) :487-515
[4]   Paper-based, printed zinc-air battery [J].
Hilder, M. ;
Winther-Jensen, B. ;
Clark, N. B. .
JOURNAL OF POWER SOURCES, 2009, 194 (02) :1135-1141
[5]   Highly conductive paper for energy-storage devices [J].
Hu, Liangbing ;
Choi, Jang Wook ;
Yang, Yuan ;
Jeong, Sangmoo ;
La Mantia, Fabio ;
Cui, Li-Feng ;
Cui, Yi .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2009, 106 (51) :21490-21494
[6]   SPECTROELECTROCHEMISTRY AND ELECTROCHEMICAL PREPARATION METHOD OF PRUSSIAN BLUE MODIFIED ELECTRODES [J].
ITAYA, K ;
ATAKA, T ;
TOSHIMA, S .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1982, 104 (18) :4767-4772
[7]   Self-powered enzyme-based biosensors [J].
Katz, E ;
Bückmann, AF ;
Willner, I .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (43) :10752-10753
[8]   Urine-activated paper batteries for biosystems [J].
Lee, KB .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2005, 15 (09) :S210-S214
[9]   Two-step activation of paper batteries for high power generation: design and fabrication of biofluid- and water-activated paper batteries [J].
Lee, Ki Bang .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2006, 16 (11) :2312-2317
[10]   Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices [J].
Martinez, Andres W. ;
Phillips, Scott T. ;
Whitesides, George M. ;
Carrilho, Emanuel .
ANALYTICAL CHEMISTRY, 2010, 82 (01) :3-10