EOG correction is a class of techniques that account for ocular artifact in the electroencephalogram (EEG) by subtracting electrooculographic data from the EEG. The purpose of this study was to evaluate four of these correction techniques (Verleger, Gasser, & Mocks, 1982 [VGM]; Gratton, Coles, & Donchin, 1983 [GCD]; Semlitsch, Presslich, Schuster, & Anderer, 1986 [SPSA]; Croft & Barry, 2000 [CB]). Blinks, vertical eye movements (VEM), and horizontal eye movements (HEM) from 26 subjects were corrected using these techniques, and eye movement event-related potentials computed to aid validation. HEMs were corrected better by CB, VGM/GCD then SPSA, VEMs by CB, VGM/GCD then SPSA, and blinks by CB, SPSA, GCD and then VGM, with the advantage of CB substantial for blinks (eta(2) >.72), VEMs (eta(2) >.60), and HEMs (eta(2) >.27). It is argued that the CB procedure adequately accounts for ocular artifact in the EEG. Reasons for the limitations of the other procedures are discussed.
引用
收藏
页码:16 / 24
页数:9
相关论文
共 29 条
[1]  
[Anonymous], 1989, Journal ofPsychophysiology
[2]  
ANTHONY BJ, 1985, ADV PSYCHOPHYSIOLOGY, V1, P167
[3]   DIFFERENTIAL CONTRIBUTIONS OF BLINKS AND VERTICAL EYE-MOVEMENTS AS ARTIFACTS IN EEG RECORDING [J].
CORBY, JC ;
KOPELL, BS .
PSYCHOPHYSIOLOGY, 1972, 9 (06) :640-&
[4]   EOG correction of blinks with saccade coefficients: a test and revision of the aligned-artefact average solution [J].
Croft, RJ ;
Barry, RJ .
CLINICAL NEUROPHYSIOLOGY, 2000, 111 (03) :444-451
[5]   Removal of ocular artifact from the EEG: a review [J].
Croft, RJ ;
Barry, RJ .
NEUROPHYSIOLOGIE CLINIQUE-CLINICAL NEUROPHYSIOLOGY, 2000, 30 (01) :5-19
[6]   Issues relating to the subtraction phase in EOG artefact correction of the EEG [J].
Croft, RJ ;
Barry, RJ .
INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2002, 44 (03) :187-195
[7]  
Croft RJ, 2000, PSYCHOPHYSIOLOGY, V37, P123
[8]   EOG correction: a new aligned-artifact average solution [J].
Croft, RJ ;
Barry, RJ .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 107 (06) :395-401
[9]   EOG correction: a new perspective [J].
Croft, RJ ;
Barry, RJ .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 107 (06) :387-394
[10]   The differential correction of eyelid-movement and globe-rotation artefact from the EEG (reply to Verleger) [J].
Croft, RJ .
JOURNAL OF PSYCHOPHYSIOLOGY, 2000, 14 (04) :207-209