Impedance-based detection of DNA sequences using a silicon transducer with PNA as the probe layer

被引:61
作者
Macanovic, A
Marquette, C
Polychronakos, C
Lawrence, MF
机构
[1] Concordia Univ, Dept Chem & Biochem, Montreal, PQ H3G 1M8, Canada
[2] McGill Univ, Montreal Childrens Hosp, Ctr Hlth, Montreal, PQ H3H 1P3, Canada
关键词
D O I
10.1093/nar/gnh003
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Electrochemical impedance measurements were used for the detection of single-strand DNA sequences using a peptide nucleic acid (PNA) probe layer immobilized onto Si/SiO2 chips. An epoxysilane layer is first immobilized onto the Si/SiO2 surface. The immobilization procedure consists of an epoxide/amine coupling reaction between the amino group of the PNA linker and the epoxide group of the silane. A 20-nucleotide sequence of PNA was used. Impedance measurements allow for the detection of the changes in charge distribution at the oxide/solution interface following modifications to the oxide surface. Due to these modifications, there are significant shifts in the semiconductor's flat-band potential after immobilization and hybridization. The results obtained using this direct and rapid approach are supported by fluorescence measurements according to classical methods for the detection of nucleic acid sequences.
引用
收藏
页数:7
相关论文
共 48 条
  • [1] Sensing of acetylcholine by a tricomponent-enzyme layered electrode using faradaic impedance spectroscopy, cyclic voltammetry, and microgravimetric quartz crystal microbalance transduction methods
    Alfonta, L
    Katz, E
    Willner, I
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (05) : 927 - 935
  • [2] Berggren C, 1999, ELECTROANAL, V11, P156, DOI 10.1002/(SICI)1521-4109(199903)11:3<156::AID-ELAN156>3.0.CO
  • [3] 2-O
  • [4] A DNA diagnostic biosensor: development, characterisation and performance
    Berney, H
    West, J
    Haefele, E
    Alderman, J
    Lane, W
    Collins, JK
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2000, 68 (1-3) : 100 - 108
  • [5] A differential capacitive biosensor using polyethylene glycol to overlay the biolayer
    Berney, H
    Alderman, J
    Lane, W
    Collins, JK
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1997, 44 (1-3) : 578 - 584
  • [6] Synthesis of a stable and specific surface plasmon resonance biosensor surface employing covalently immobilized peptide nucleic acids
    Burgener, M
    Sänger, M
    Candrian, U
    [J]. BIOCONJUGATE CHEMISTRY, 2000, 11 (06) : 749 - 754
  • [7] Quartz crystal microbalance study of DNA immobilization and hybridization for nucleic acid sensor development
    Caruso, F
    Rodda, E
    Furlong, DF
    Niikura, K
    Okahata, Y
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (11) : 2043 - 2049
  • [8] Adsorptions of plasma proteins and their elutabilities from a polysiloxane surface studied by an on-line acoustic wave sensor
    Cavic, BA
    Thompson, M
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (07) : 1523 - 1531
  • [9] Electrochemical DNA biosensor for environmental monitoring
    Chiti, G
    Marrazza, G
    Mascini, M
    [J]. ANALYTICA CHIMICA ACTA, 2001, 427 (02) : 155 - 164
  • [10] Immobilization of homooligonucleotide probe layers onto Si/SiO2 substrates:: characterization by electrochemical impedance measurements and radiolabelling
    Cloarec, JP
    Deligianis, N
    Martin, JR
    Lawrence, I
    Souteyrand, E
    Polychronakos, C
    Lawrence, MF
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (05) : 405 - 412