A differential capacitive biosensor using polyethylene glycol to overlay the biolayer

被引:26
作者
Berney, H [1 ]
Alderman, J
Lane, W
Collins, JK
机构
[1] Univ Coll, Natl Microelect Res Ctr, Cork, Ireland
[2] Univ Coll, Dept Microbiol, Cork, Ireland
关键词
differential capacitive biosensor; polyethylene glycol; transferrin;
D O I
10.1016/S0925-4005(97)00239-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The feasibility of immunosensors based on capacitance measurements on semiconductor-immobilized antibody-electrolyte heterostructures is being investigated. Capacitance measurements on biosensors succeed only if the successive biomolecular layers grafted onto the heterostructures an sufficiently electrically insulating and retain their recognizing ability (Jaffrezic-Renault et al., Sensors and Actuators B 15-16 (1993) 458-462: Bergveld, Biosensors and Bioelectronics 6 (1991) 55-72, Schasfoort et al., Anal. Chim. Acta 235 (1990) 323-329). However. as with other groups, our system showed no reproducible capacitance decrease on addition of antigen. The biolayer was not sufficiently insulating or did not have a suitable dielectric character. Tolls were moving through or around this layer causing 'shorting' of the system. In all attempt to drive the system toward exclusion of ions from the biolayer, an overlay of non-conducting polymer, in the form of polyethylene glycol (PEG), was added. Our results indicate that PEG forms an insulating layer on a bare chip surface, causing the capacitance to drop. The response was self-consistent and reproducible. On surfaces where there was protein pre-immobilized or pre-adsorbed, the PEG could not form a continous, integral layer and a smaller drop in capacitance was observed. There is a difference in the response of single layers of protein, where only antibody is immobilized, and triple protein layers, where antibody was immobilized, antigen added and a secondary antibody bound. These results show the possibility of developing a differential capacitive biosensor. (C) 1997 Elsevier Science S.A.
引用
收藏
页码:578 / 584
页数:7
相关论文
共 28 条
  • [1] IRON TRANSPORT AND STORAGE PROTEINS
    AISEN, P
    LISTOWSKY, I
    [J]. ANNUAL REVIEW OF BIOCHEMISTRY, 1980, 49 : 357 - 393
  • [2] ATHA DH, 1981, J BIOL CHEM, V256, P2108
  • [3] A CRITICAL-EVALUATION OF DIRECT ELECTRICAL PROTEIN-DETECTION METHODS
    BERGVELD, P
    [J]. BIOSENSORS & BIOELECTRONICS, 1991, 6 (01) : 55 - 72
  • [4] Creighton T. E., 1992, PROTEIN FOLDING
  • [5] IMPEDANCE BASED SENSING OF THE SPECIFIC BINDING REACTION BETWEEN STAPHYLOCOCCUS ENTEROTOXIN-B AND ITS ANTIBODY ON AN ULTRA-THIN PLATINUM FILM
    DESILVA, MS
    ZHANG, Y
    HESKETH, PJ
    MACLAY, GJ
    GENDEL, SM
    STETTER, JR
    [J]. BIOSENSORS & BIOELECTRONICS, 1995, 10 (08) : 675 - 682
  • [6] PHYSICOCHEMICAL CHARACTERIZATION OF COVALENTLY BONDED ALKYL MONOLAYERS ON SILICA SURFACES
    DUVAULT, Y
    GAGNAIRE, A
    GARDIES, F
    JAFFREZICRENAULT, N
    MARTELET, C
    MOREL, D
    SERPINET, J
    DUVAULT, JL
    [J]. THIN SOLID FILMS, 1990, 185 (01) : 169 - 179
  • [7] EDDOWES MJ, 1987, BIOSENSORS, V3, P1
  • [8] EIGLER FS, 1991, Patent No. 5077210
  • [9] REAL-TIME MONITORING OF IMMUNOCHEMICAL INTERACTIONS WITH A TANTALUM CAPACITANCE FLOW-THROUGH CELL
    GEBBERT, A
    ALVAREZICAZA, M
    STOCKLEIN, W
    SCHMID, RD
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (09) : 997 - 1003
  • [10] Harris J. M., 1992, POLY ETHYLENE GLYCOL