Fluorimetric determination of magnesium and aluminum via complexation with oxine in high-performance liquid chromatography

被引:26
作者
Takeuchi, T [1 ]
Inoue, S [1 ]
Yamamoto, M [1 ]
Tsuji, M [1 ]
Miwa, T [1 ]
机构
[1] Gifu Univ, Fac Engn, Dept Chem, Gifu 5011193, Japan
关键词
derivatization; LC; magnesium; aluminum; oxine;
D O I
10.1016/S0021-9673(00)01209-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Aluminum and magnesium were determined by fluorimetric detection via pre-column and/or in-column derivatization with 8-hydroxyquinoline (oxine) in high-performance liquid chromatography. The oxine complex of aluminum was selectively detected when the eluent contained no oxine, whereas the aluminum and magnesium complexes could be simultaneously detected when the eluent contained oxine. The sensitivity was improved by using eluents containing oxine by a factor of 7.1 for aluminum, and the detection limits at S/N=3 were 18 and 16 ng/ml for magnesium and aluminum, respectively. The present system was applied to the determination of magnesium and aluminum in various water samples. (C) 2001 Elsevier Science BN. All rights reserved.
引用
收藏
页码:373 / 376
页数:4
相关论文
共 12 条
[1]  
BAILOCCHI C, 1988, ANALYST, V113, P805
[2]   APPLICATION OF HPLC TO INORGANIC ANALYSIS .7. COMPARISON BETWEEN PRE-COLUMN-DERIVATIZATION AND ON-COLUMN DERIVATIZATION FOR SEPARATION OF DIFFERENT METAL OXINATES - QUANTITATIVE-DETERMINATION OF MN(II) BESIDES MN(III) IONS [J].
HOFFMANN, BW ;
SCHWEDT, G .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1982, 5 (08) :439-440
[3]  
Kokot Z, 1998, CHEM ANAL-WARSAW, V43, P215
[4]   High-performance liquid chromatography with electrochemical detection for the determination of vanadium(V) in river water and mussel samples [J].
Nagaosa, Y ;
Kimata, Y .
ANALYTICA CHIMICA ACTA, 1996, 327 (03) :203-209
[5]   Reversed-phase chromatographic behavior of metal complexes with 8-hydroxyquinoline and its derivatives [J].
Nagaosa, Y ;
Ishida, T .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (05) :693-703
[6]  
NAGAOSA Y, 1996, INT J ENVIRON AN CH, V61, P231
[7]   DETERMINATION OF TRACE LEVELS OF COPPER(II), ALUMINUM(III) AND IRON(III) BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING A NOVEL ONLINE SAMPLE PRECONCENTRATION TECHNIQUE [J].
RYAN, E ;
MEANEY, M .
ANALYST, 1992, 117 (09) :1435-1439
[8]  
SAITO M, 1996, CHEM LETT, P203
[9]   Fluorometric determination of serum and urinary aluminium with 8-quinolinol by kinetic-differentiation-mode micellar chromatography [J].
Sato, M ;
Yoshimura, H ;
Shimmura, T ;
Obi, H ;
Hatakeyama, S ;
Kaneko, E ;
Hoshino, H ;
Yotsuyanagi, T .
JOURNAL OF CHROMATOGRAPHY A, 1997, 789 (1-2) :361-367
[10]   SEPARATION OF AL(III), CU(II), GA(III), AND FE(III), AS 8-HYDROXYQUINOLINE - 5 - SULFONIC-ACID COMPLEXES BY HIGH - PERFORMANCE LIQUID CHROMATOGRAPHY [J].
SHIJO, Y ;
SAITOH, A ;
SUZUKI, K .
CHEMISTRY LETTERS, 1989, (02) :181-184