Living donor kidneys: Usefulness of multi-detector row CT for comprehensive evaluation

被引:65
作者
Kim, JK
Park, SY
Kim, HJ
Kim, CS
Ahn, HJ
Ahn, TY
Cho, KS
机构
[1] Univ Ulsan, Asan Med Ctr, Dept Radiol, Seoul 138736, South Korea
[2] Univ Ulsan, Asan Med Ctr, Dept Urol, Seoul 138736, South Korea
关键词
computed tomography (CT); angiography; multidetector row; kidney; CT; transplantation; urography;
D O I
10.1148/radiol.2293021098
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate in living renal donors the usefulness of multi-detector row computed tomography (CT) in the assessment of renal vasculature and the upper urinary tract. MATERIALS AND METHODS: Four-channel multi-detector row CT scans were obtained in 77 patients. Vascular phase scans were used for CT angiography; excretory phase scans, for CT urography. At CT angiography, two independent observers evaluated the number of arteries and veins and the presence of early-branching arteries. CT urographic images were evaluated with regard to the opacification of the urinary tract and for abnormalities. Findings of CT angiography and urography were compared with surgical findings. Interobserver agreement between CT angiographic and surgical findings was quantified with weighted K statistics. Sensitivity and specificity of CT angiography in identifying supernumerary vessels and early-branching arteries were also evaluated. To evaluate the radiation dose to patients, weighted CT dose index (DI) was assessed for each scan. RESULTS: Agreement between CT angiographic and surgical findings was excellent for the number of renal arteries (kappa = 0.896) and veins (kappa = 0.843). Detection rate of CT angiography was 98% (89 of 91) for arteries and 98% (83 of 85) for veins. The respective sensitivity and specificity of CT angiography were 86% (12 of 14) and 100% (65 of 65) for supernumerary arteries, 100% (11 of 11) and 100% (66 of 66) for early-branching arteries, and 75% (six of eight) and 100% (69 of 69) for supernumerary veins. At CT urography, collecting systems and proximal ureters were well opacified in all patients; two patients had underrotated kidneys without obstruction. The weighted CT DI was 10.19 mGy for unenhanced and excretory phase scans and 12.88 mGy for the vascular phase scan. CONCLUSION: Multi-detector row CT can help assess well the renal vasculature and the urinary tract of living renal donors. RSNA, 2003.
引用
收藏
页码:869 / 876
页数:8
相关论文
共 24 条
[1]  
ALFREY EJ, 1995, TRANSPLANTATION, V59, P643
[2]   Urinary tract abnormalities: Initial experience with multi-detector row CT urography [J].
Caoili, EM ;
Cohan, RH ;
Korobkin, M ;
Platt, JF ;
Francis, IR ;
Faerber, GJ ;
Montie, JE ;
Ellis, JH .
RADIOLOGY, 2002, 222 (02) :353-360
[3]   Multidetector CT urography with abdominal compression and three-dimensional reconstruction [J].
Chow, LC ;
Sommer, FG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (04) :849-855
[4]   Helical CT angiography for examination of living renal donors [J].
Cochran, ST ;
Krasny, RM ;
Danovitch, GM ;
Rajfer, J ;
Barbaric, ZM ;
Wilkinson, A ;
Rosenthal, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (06) :1569-1573
[5]   Helical CT examination of potential kidney donors [J].
Dachman, AH ;
Newmark, GM ;
Mitchell, MT ;
Woodle, ES .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) :193-200
[6]   Stair-step artifacts with single versus multiple detector-row helical CT [J].
Fleischmann, D ;
Rubin, GD ;
Paik, DS ;
Yen, SY ;
Hilfiker, PR ;
Beaulieu, CF ;
Napel, S .
RADIOLOGY, 2000, 216 (01) :185-196
[7]   Preoperative evaluation of living renal donors: Comparison of CT angiography and MR angiography [J].
Halpern, EJ ;
Mitchell, DG ;
Wechsler, RJ ;
Outwater, EK ;
Moritz, MJ ;
Wilson, GA .
RADIOLOGY, 2000, 216 (02) :434-439
[8]   Compression CT urography: A comparison with IVU in the opacification of the collecting system and ureters [J].
Heneghan, JP ;
Kim, DH ;
Leder, RA ;
DeLong, D ;
Nelson, RC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (03) :343-347
[9]  
*INT EL COMM, 1999, INT EL COMM PUBL
[10]   Spiral CT angiography of the renal arteries: Should a scan delay based on a test bolus injection or a fixed scan delay be used to obtain maximum enhancement of the vessels? [J].
Kaatee, R ;
Van Leeuwen, MS ;
De Lange, EE ;
Wilting, JE ;
Beek, FJA ;
Beutler, JJ ;
Mali, WPTM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (04) :541-547