Resuscitation of the injured patient with polymerized stroma free hemoglobin does not produce systemic or pulmonary hypertension

被引:37
作者
Johnson, JL
Moore, EE
Offner, PJ
Haenel, JB
Hides, GA
Tamura, DY
机构
[1] Univ Colorado, Hlth Sci Ctr, Denver Hlth Med Ctr, Dept Surg, Denver, CO 80204 USA
[2] Northfield Labs, Evanston, IL USA
关键词
D O I
10.1016/S0002-9610(98)00275-X
中图分类号
R61 [外科手术学];
学科分类号
摘要
BACKGROUND: Hemoglobin-based blood substitutes appear poised to deliver the promise of a universally compatible, disease-free alternative to banked blood. However, vasoconstriction following administration of tetrameric hemoglobins has been problematic, likely because of nitric oxide binding. Polymerized hemoglobin is effectively excluded from the abluminal space because of its size, and is thus less likely to perturb vasorelaxation. We therefore hypothesized that hemodynamic responses would be no different in injured patients receiving polymerized hemoglobin versus banked blood. METHODS: Injured patients requiring urgent transfusion were randomized to receive either polymerized hemoglobin or banked blood. Systemic arterial pressure, pulmonary arterial pressure, cardiac index, pulmonary capillary wedge pressure, systemic vascular resistance, and pulmonary vascular resistance were measured serially. RESULTS: There was no difference in any of the measured hemodynamic parameters between patients resuscitated with polymerized hemoglobin versus blood. CONCLUSIONS: Polymerized hemoglobin given in large doses to injured patients lacks the vasoconstrictive effects reported in the use of other hemoglobin-based blood substitutes. This supports the continued investigation of polymerized hemoglobin in injured patients requiring urgent transfusion. Am J Surg. 1998;176:612-617. (C) 1998 by Excerpta Medica, Inc.
引用
收藏
页码:612 / 615
页数:4
相关论文
共 13 条
  • [1] The effects of cross-linked hemoglobin on regional vascular conductance in dogs
    Dietz, NM
    Martin, CM
    BeltrandelRio, AG
    Joyner, MJ
    [J]. ANESTHESIA AND ANALGESIA, 1997, 85 (02) : 265 - 273
  • [2] Mechanism of NO-induced oxidation of myoglobin and hemoglobin
    Eich, RF
    Li, TS
    Lemon, DD
    Doherty, DH
    Curry, SR
    Aitken, JF
    Mathews, AJ
    Johnson, KA
    Smith, RD
    Phillips, GN
    Olson, JS
    [J]. BIOCHEMISTRY, 1996, 35 (22) : 6976 - 6983
  • [3] The toxicities of native and modified hemoglobins
    Everse, J
    Hsia, N
    [J]. FREE RADICAL BIOLOGY AND MEDICINE, 1997, 22 (06) : 1075 - 1099
  • [4] Gould S. A., 1995, Journal of Trauma, V39, P157
  • [5] ARTIFICIAL BLOOD - CURRENT STATUS OF HEMOGLOBIN-SOLUTIONS
    GOULD, SA
    SEHGAL, LR
    SEHGAL, HL
    MOSS, GS
    [J]. CRITICAL CARE CLINICS, 1992, 8 (02) : 293 - 309
  • [6] The first randomized trial of human polymerized hemoglobin as a blood substitute in acute trauma and emergent surgery
    Gould, SA
    Moore, EE
    Hoyt, DB
    Burch, JM
    Haenel, JB
    Garcia, J
    DeWoskin, R
    Moss, GS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1998, 187 (02) : 113 - 120
  • [7] THE EFFICACY OF POLYMERIZED PYRIDOXYLATED HEMOGLOBIN SOLUTION AS AN O-2 CARRIER
    GOULD, SA
    SEHGAL, LR
    ROSEN, AL
    SEHGAL, HL
    MOSS, GS
    [J]. ANNALS OF SURGERY, 1990, 211 (04) : 394 - 398
  • [8] Gould SA, 1996, WORLD J SURG, V20, P1200
  • [9] HAUSER CJ, 1982, CRIT CARE MED, V10, P283, DOI 10.1097/00003246-198204000-00010
  • [10] SYSTEMIC AND PULMONARY-HYPERTENSION AFTER RESUSCITATION WITH CELL-FREE HEMOGLOBIN
    HESS, JR
    MACDONALD, VW
    BRINKLEY, WW
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (04) : 1769 - 1778