USPIO-enhanced direct MR imaging of thrombus: Preclinical evaluation in rabbits

被引:39
作者
Schmitz, SA
Winterhalter, S
Schiffler, S
Gust, R
Wagner, S
Kresse, M
Coupland, SE
Semmler, W
Wolf, KJ
机构
[1] Free Univ Berlin, Klinikum Benjamin Franklin, Dept Radiol & Nucl Med, D-12200 Berlin, Germany
[2] Free Univ Berlin, Klinikum Benjamin Franklin, Dept Pathol, D-12200 Berlin, Germany
[3] Free Univ Berlin, Inst Diagnost Res, D-12200 Berlin, Germany
[4] Humboldt Univ, Charite, Dept Radiol, Berlin, Germany
关键词
animals; contrast media; experimental tudies; magnetic resonance; (MR); embolism; experimental studies; iron; thrombosis; MR; veins;
D O I
10.1148/radiol.2211001632
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To test the hypothesis that ultrasmall superparamagnetic iron oxide (USPIO) particles may diffuse into nonendothelialized fresh thrombi and thus allow for direct magnetic resonance (MR) imaging of a thrombus. MATERIALS AND METHODS: Stagnation thrombi of different thrombus ages (1, 3, 5, 7, and 9 days) were induced in the external jugular veins of 25 rabbits. Direct MR imaging of thrombi was performed by using a fat-saturated Tl-weighted gradient-echo sequence (three-dimensional [3D] magnetization prepared rapid acquisition gradient echo) before and 24 hours after intravenous administration of USPIO (particle size, 25 nm; 200 mu mol per kilogram of body weight). Thrombus length on 3D reconstruction images was compared with that depicted on a radiographic venogram and with histologic findings (joint reference standard). In addition, T2*-weighted gradient-echo images were acquired and scored semiquantitatively. RESULTS: The hyperintensity of the thrombus segment depicted on T1-weighted images (thrombus length determined with 3D reconstruction images divided by true thrombus length) increased significantly after administration of contrast medium at a thrombus age of 3 days (0.6 +/- 0.4 [SD] to 0.8 +/- 0.4; P = .02), 5 days (0.1 +/- 0.1 to 1.0 +/- 0.1; P < .001), and 7 days (0 to 0.6 +/- 0.4; P = .02), but not at an age of 1 and 9 days. No significant change in the thrombus signal intensity was observed on T2*-weighted images. CONCLUSION: The animal model showed that direct MR imaging of the thrombus improved 24 hours after USPIO administration with a T1-weighted sequence. No improvement was seen with the T2*-weighted sequence.
引用
收藏
页码:237 / 243
页数:7
相关论文
共 19 条
[1]   MR angiography with an ultrasmall superparamagnetic iron oxide blood pool agent [J].
Anzai, Y ;
Prince, MR ;
Chenevert, TL ;
Maki, JH ;
Londy, F ;
London, M ;
McLachlan, SJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01) :209-214
[2]   EFFECT OF METHEMOGLOBIN FORMATION ON THE MR APPEARANCE OF SUBARACHNOID HEMORRHAGE [J].
BRADLEY, WG ;
SCHMIDT, PG .
RADIOLOGY, 1985, 156 (01) :99-103
[3]   SUPERPARAMAGNETIC IRON-OXIDES AS POSITIVE MR CONTRAST AGENTS - INVITRO AND INVIVO EVIDENCE [J].
CHAMBON, C ;
CLEMENT, O ;
LEBLANCHE, A ;
SCHOUMANCLAEYS, E ;
FRIJA, G .
MAGNETIC RESONANCE IMAGING, 1993, 11 (04) :509-519
[4]  
ELKOURI D, 1992, INT ANGIOL, V11, P304
[5]   VENOUS THROMBOSIS - CLINICAL AND EXPERIMENTAL MR IMAGING [J].
ERDMAN, WA ;
WEINREB, JC ;
COHEN, JM ;
BUJA, LM ;
CHANEY, C ;
PESHOCK, RM .
RADIOLOGY, 1986, 161 (01) :233-238
[6]  
EVANS RJ, 1973, J PATHOL, V109, pP1
[7]   RAPID 3-DIMENSIONAL MR IMAGING USING THE FLASH TECHNIQUE [J].
FRAHM, J ;
HAASE, A ;
MATTHAEI, D .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (02) :363-368
[8]  
FRANCIS CW, 1995, THROMB HAEMOSTASIS, V73, P386
[9]  
GIBBS N, 1960, BRIT J SURG, V45, P209
[10]  
HADFIELD G, 1950, ANN ROY COLL SURG, V6, P219