Clinical relative biological effectiveness of low-energy x-rays emitted by miniature x-ray devices

被引:96
作者
Brenner, DJ
Leu, CS
Beatty, JF
Shefer, RE
机构
[1] Columbia Univ, Ctr Radiol Res, New York, NY 10032 USA
[2] Newton Sci Inc, Cambridge, MA 02141 USA
[3] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
关键词
D O I
10.1088/0031-9155/44/2/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Several groups are developing ultra-miniature x-ray machines for clinical use in radiation therapy. Current systems are for interstitial radiosurgery and for intravascular insertion for irradiation to prevent re-stenosis. Typical generating voltages are low, in the 20 to 40 kV range. It is well established that the biological effectiveness of such low-energy photons is large compared with higher-energy gamma rays, because of the dominance of photoelectric absorption at low energies. We have used microdosimetric analyses to estimate RBEs for such devices, both at low doses and clinically relevant doses, relative to radiations from Co-60, Ir-192, I-125 and Sr-90/Y-90. The RBEs at clinically relevant doses and dose rates for these low-energy x-ray sources are considerably above unity, both relative to Co-60 and to Ir-192 photons, and also relative to I-125 and Sr-90/Y-90 brachytherapy sources. As a function of depth, the overall effect of the change in dose and the change in beam spectrum results in beams whose biologically weighted dose (dose x RBE) decreases with depth somewhat more slowly than does the physical dose. The estimated clinically relevant RBEs are sufficiently large that they should be taken into account during the treatment design stage.
引用
收藏
页码:323 / 333
页数:11
相关论文
共 42 条
[1]  
Akima H., 1978, ACM Transactions on Mathematical Software, V4, P148, DOI 10.1145/355780.355786
[2]  
[Anonymous], 1987, FRACTIONATION RADIOT
[3]  
[Anonymous], 1986, 40 ICRU
[4]   LOW DOSE-RATE EFFECTS OF CESIUM-137 AND I-125 ON CELL-SURVIVAL, CELL PROGRESSION, AND CHROMOSOMAL ALTERATIONS [J].
ARSLAN, NC ;
GEARD, CR .
AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 1986, 9 (06) :521-526
[5]   A new miniature x-ray device for interstitial radiosurgery: Dosimetry [J].
Beatty, J ;
Biggs, PJ ;
Gall, K ;
Okunieff, P ;
Pardo, FS ;
Harte, KJ ;
Dalterio, MJ ;
Sliski, AP .
MEDICAL PHYSICS, 1996, 23 (01) :53-62
[6]   RBE OF 20 KV AND 70 KV X-RAYS DETERMINED FOR SURVIVAL OF V-79 CELLS [J].
BISTROVIC, M ;
BISCAN, M ;
VICULIN, T .
RADIOTHERAPY AND ONCOLOGY, 1986, 7 (02) :175-180
[7]   THE APPLICATION OF TRACK CALCULATIONS TO RADIOBIOLOGY .2. CALCULATIONS OF MICRODOSIMETRIC QUANTITIES [J].
BRENNER, DJ ;
ZAIDER, M .
RADIATION RESEARCH, 1984, 98 (01) :14-25
[8]   CONDITIONS FOR THE EQUIVALENCE OF CONTINUOUS TO PULSED LOW-DOSE RATE BRACHYTHERAPY [J].
BRENNER, DJ ;
HALL, EJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (01) :181-190
[9]   ENHANCED RISK FROM LOW-ENERGY SCREEN FILM MAMMOGRAPHY X-RAYS [J].
BRENNER, DJ ;
AMOLS, HI .
BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (742) :910-914
[10]   The radiobiology of intravascular irradiation [J].
Brenner, DJ ;
Miller, RC ;
Hall, EJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (04) :805-810