Laser in situ keratomileusis with a scanning excimer laser for the correction of low to moderate myopia with and without astigmatism

被引:26
作者
Balazsi, G
Mullie, M
Lasswell, L
Lee, PA
Duh, YJ
机构
[1] Clin Laservue, Montreal, PQ, Canada
[2] Bausch & Lomb Surg, Clin Programs Grp, Claremont, CA USA
关键词
D O I
10.1016/S0886-3350(01)01017-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the safety and effectiveness of and patient satisfaction with laser in situ keratomileusis (LASIK) performed with a scanning excimer laser by experienced surgeons to correct low and moderate levels of myopia and astigmatism. Setting: Clinique Laservue, Montreal, Quebec, Canada. Methods: A consecutive series of 125 patients (236 eyes) with myopia of -0.5 to -7.0 diopters (D) and cylinder less than 2.5 D were enrolled in this single-center prospective clinical trial. The patients were treated with LASIK and followed for 6 months, The System-ALK Automated Corneal Shaper((R)) microkeratome (Bausch & Lomb Surgical) with a 180 mum thickness plate and the Technolas((R)) 217 excimer laser (Bausch & Lomb Surgical) with PlanoScan software for the stromal ablation were used in all procedures. Since this version of PlanoScan tended to undercorrect, a mean of 14.7% was added to the standard nomogram. Patient satisfaction was assessed by questionnaires administered preoperatively and 1 and 6 months postoperatively, Retreatments for enhancement were not performed during the 6-month follow-up, Results: Six months after LASIK (86.4% follow-up), the mean postoperative manifest spherical equivalent was +0.02 D +/- 0.64 (SD) compared with a preoperative mean of -4.01 +/- 1.59 D. The uncorrected visual acuity was 20/40 or better in 94.6% of eyes and 20/20 or better in 81.9%. A total of 91.2% were within +/- 1.0 D of emmetropia and 73.0% were within +/- 0.5 D. Only 2 eyes were overcorrected by > 1.0 D. Of the eyes with astigmatic myopia, 86.8% were within +/- 1.0 D of the intended cylinder correction (by vector analysis) and 73.0% were within +/- 0.5 D. The refractions were generally stable after 1 month, and the change in refraction between postoperative examinations was within 0.5 D in 88.0% of eyes. A 1-line decrease in best spectacle-corrected visual acuity was seen in 11.3% of eyes, and no eye lost more than 1 line. An increase of 1 or 2 lines was seen in 45.1%. No intraoperative problems occurred, and the interface was clear in all eyes. At 6 months, most symptoms present significantly more frequently than preoperatively were "mild"; none were "marked" or "severe." A total of 90.5% of eyes were reported with marked to extreme improvement in the overall quality of vision, and 99.0% of patients said they would choose LASIK surgery again. Conclusions: Mild to moderate myopia, with and without astigmatism, was corrected safely, effectively, and predictably with a high degree of patient satisfaction using LASIK with a scanning excimer laser and the System-ALK Automated Corneal Shaper, (C) 2001 ASCRS and ESCRS.
引用
收藏
页码:1942 / 1951
页数:10
相关论文
共 37 条
[31]   Complications of laser in situ keratomileusis for the correction of myopia [J].
Stulting, RD ;
Carr, JD ;
Thompson, KP ;
Waring, GO ;
Wiley, WM ;
Walker, JG .
OPHTHALMOLOGY, 1999, 106 (01) :13-20
[32]   CORNEAL SUBEPITHELIAL INFILTRATES FOLLOWING EXCIMER-LASER PHOTOREFRACTIVE KERATECTOMY [J].
TEAL, P ;
BRESLIN, C ;
ARSHINOFF, S ;
EDMISON, D .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (05) :516-518
[33]  
Tsai RJF, 1997, J REFRACT SURG, V13, pS427
[34]  
Wang Z, 1997, J REFRACT SURG, V13, P528
[35]   LASIK: Management of common complications [J].
Wilson, SE .
CORNEA, 1998, 17 (05) :459-467
[36]  
Zaldivar R, 1998, J REFRACT SURG, V14, P19
[37]  
Zaldivar R, 1997, J REFRACT SURG, V13, P614