An Efficient and Accurate Prediction of the Stability of Percutaneous Fixation of Acetabular Fractures With Finite Element Simulation

被引:13
作者
Shim, V. B. [1 ]
Boeshme, J. [2 ]
Vaitl, P. [2 ]
Josten, C. [2 ]
Anderson, I. A. [1 ]
机构
[1] Univ Auckland, Auckland Bioengn Inst, Auckland 1, New Zealand
[2] Univ Leipzig, Dept Trauma Plast & Reconstruct Surg, Leipzig, Germany
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2011年 / 133卷 / 09期
关键词
biomechanics; bone; fasteners; finite element analysis; fracture; mechanical stability; physiological models; surgery; SCREW FIXATION; MODEL;
D O I
10.1115/1.4004821
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Posterior wall fracture is one of the most common fracture types of the acetabulum and a conventional approach is to perform open reduction and internal fixation with a plate and screws. Percutaneous screw fixations, on the other hand, have recently gained attention due to their benefits such as less exposure and minimization of blood loss. However their biomechanical stability, especially in terms interfragmentary movement, has not been investigated thoroughly. The aims of this study are twofold: (1) to measure the interfragmentary movements in the conventional open approach with plate fixations and the percutaneous screw fixations in the acetabular fractures and compare them; and (2) to develop and validate a fast and efficient way of predicting the interfragmentary movement in percutaneous fixation of posterior wall fractures of the acetabulum using a 3D finite element (FE) model of the pelvis. Our results indicate that in single fragment fractures of the posterior wall of the acetabulum, plate fixations give superior stability to screw fixations. However screw fixations also give reasonable stability as the average gap between fragment and the bone remained less than 1 mm when the maximum load was applied. Our finite element model predicted the stability of screw fixation with good accuracy. Moreover, when the screw positions were optimized, the stability predicted by our FE model was comparable to the stability obtained by plate fixations. Our study has shown that FE modeling can be useful in examining biomechanical stability of osteosynthesis and can potentially be used in surgical planning of osteosynthesis. [DOI: 10.1115/1.4004821]
引用
收藏
页数:4
相关论文
共 23 条
[1]
American Society for Testing and Materials, 2008, F183908 ASTM
[2]
The use of a virtual three-dimensional model to evaluate the intraosseous space available for percutaneous screw fixation of acetabular fractures [J].
Attias, N ;
Lindsey, RW ;
Starr, AJ ;
Borer, D ;
Bridges, K ;
Hipp, JA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (11) :1520-1523
[3]
Baumgaertner M R, 1999, J Am Acad Orthop Surg, V7, P54
[4]
Geometric modeling of the human torso using cubic hermite elements [J].
Bradley, CP ;
Pullan, AJ ;
Hunter, PJ .
ANNALS OF BIOMEDICAL ENGINEERING, 1997, 25 (01) :96-111
[5]
Preoperative planning in pelvic and acetabular surgery: The value of advanced computerised planning modules [J].
Cimerman, Matej ;
Kristan, Anze .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (04) :442-449
[6]
Type of Hip Fracture Determines Load Share in Intramedullary Osteosynthesis [J].
Eberle, Sebastian ;
Gerber, Claus ;
von Oldenburg, Geert ;
Hungerer, Sven ;
Augat, Peter .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (08) :1972-1980
[7]
Three-dimensional finite element analysis of several internal and external pelvis fixations [J].
García, JM ;
Doblaré, M ;
Seral, B ;
Seral, F ;
Palanca, D ;
Gracia, L .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (05) :516-522
[8]
Gordon J, 1989, J Rehabil Res Dev, V26, P33
[9]
COMMINUTED FRACTURES OF THE POSTERIOR WALL OF THE ACETABULUM - A BIOMECHANICAL EVALUATION OF FIXATION METHODS [J].
GOULET, JA ;
ROULEAU, JP ;
MASON, DJ ;
GOLDSTEIN, SA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (10) :1457-1463
[10]
The initial phase of fracture healing is specifically sensitive to mechanical conditions [J].
Klein, P ;
Schell, H ;
Streitparth, F ;
Heller, M ;
Kassi, JP ;
Kandziora, F ;
Bragulla, H ;
Haas, NP ;
Duda, GN .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2003, 21 (04) :662-669