Sample handler for x-ray tomographic microscopy and image-guided failure assessment -: art. no. 076106

被引:4
作者
Wyss, P
Thurner, P
Brönnimann, R
Sennhauser, U
Stampanoni, M
Abela, R
Müller, R
机构
[1] EMPA, Swiss Fed Labs Mat Testing & Res, Elect Metrol, CH-8600 Dubendorf, Switzerland
[2] Paul Scherrer Inst, SLS, CH-5232 Villigen, Switzerland
[3] ETH, Inst Biomed Engn, CH-8044 Zurich, Switzerland
[4] Univ Zurich, CH-8044 Zurich, Switzerland
关键词
D O I
10.1063/1.1979475
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
X-ray tomographic microscopy (XTM) yields a three-dimensional data model of an investigated specimen. XTM providing micrometer resolution requires synchrotron light, high resolution area detectors, and a precise sample handler. The sample handler has a height of 270 mm only, is usable for 1 mu m resolution, and is able to carry loading machines with a weight of up to 20 kg. This allows exposing samples to load between scans for image-guided failure assessment. This system has been used in the XTM end station of the materials science beamline of the Swiss Light Source at the Paul Scherrer Institut. (c) 2005 American Institute of Physics.
引用
收藏
页数:3
相关论文
共 7 条
[1]   Three-dimensional imaging of nerve tissue by x-ray phase-contrast microtomography [J].
Beckmann, F ;
Heise, K ;
Kölsch, B ;
Bonse, U ;
Rajewsky, MF ;
Bartscher, M ;
Biermann, T .
BIOPHYSICAL JOURNAL, 1999, 76 (01) :98-102
[2]  
MULLER B, 2003, BB 84CD INT S COMP T, P19
[3]   Time-lapsed microstructural imaging of bone failure behavior [J].
Nazarian, A ;
Müller, R .
JOURNAL OF BIOMECHANICS, 2004, 37 (01) :55-65
[4]   Bragg magnifier:: A detector for submicrometer x-ray computer tomography [J].
Stampanoni, M ;
Borchert, G ;
Abela, R ;
Rüegsegger, P .
JOURNAL OF APPLIED PHYSICS, 2002, 92 (12) :7630-7635
[5]   High resolution X-ray detector for synchrotron-based microtomography [J].
Stampanoni, M ;
Borchert, G ;
Wyss, P ;
Abela, R ;
Patterson, B ;
Hunt, S ;
Vermeulen, D ;
Rüegsegger, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 491 (1-2) :291-301
[6]   Functional micro-imaging of soft and hard tissue using synchrotron light [J].
Thurner, PJ ;
Wyss, P ;
Voide, R ;
Stauber, M ;
Müller, B ;
Stampanoni, M ;
Hubbell, JA ;
Müller, R ;
Sennhauser, U .
DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 :112-128
[7]   A high-throughput x-ray microtomography system at the Advanced Photon Source [J].
Wang, YX ;
De Carlo, F ;
Mancini, DC ;
McNulty, I ;
Tieman, B ;
Bresnahan, J ;
Foster, I ;
Insley, J ;
Lane, P ;
von Laszewski, G ;
Kesselman, C ;
Su, MH ;
Thiebaux, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (04) :2062-2068