Deeply penetrating in vivo photoacoustic imaging using a clinical ultrasound array system

被引:234
作者
Kim, Chulhong [1 ]
Erpelding, Todd N. [2 ]
Jankovic, Ladislav [2 ]
Pashley, Michael D. [2 ]
Wang, Lihong V. [1 ]
机构
[1] Washington Univ, Opt Imaging Lab, Dept Biomed Engn, St Louis, MO 63130 USA
[2] Philips Res N Amer, Briarcliff Manor, NY 10510 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1364/BOE.1.000278
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
Using a hand-held photoacoustic probe integrated with a clinical ultrasound array system, we successfully imaged objects deeply positioned in biological tissues. The optical contrasts were enhanced by methylene blue with a concentration of similar to 30 mM. The penetration depth reached similar to 5.2 cm in chicken breast tissue by using 650-nm wavelength, which is similar to 4.7 times the 1/e optical penetration depth. This imaging depth was achieved using a laser fluence on the tissue surface of only 3 mJ/cm(2), which is 1/7 of the American National Standards Institute (ANSI) safety limit (20 mJ/cm(2)). The noise equivalent sensitivity at this depth was similar to 11 mM. Further, after intradermal injection of methylene blue in a rat, a sentinel lymph node was easily detected in vivo, beneath a 2-cm thick layer of chicken breast. Also, blood located 3.5 cm deep in the rat was clearly imaged with intrinsic contrast. We have photoacoustically guided insertion of a needle into a rat sentinel lymph node with accumulated methylene blue. These results highlight the clinical potential of photoacoustic image-guided identification and needle biopsy of sentinel lymph nodes for axillary staging in breast cancer patients. (C) 2010 Optical Society of America
引用
收藏
页码:278 / 284
页数:7
相关论文
共 24 条
[1]
Lymphatic mapping and sentinel node biopsy in the patient with breast cancer [J].
Albertini, JJ ;
Lyman, GH ;
Cox, C ;
Yeatman, T ;
Balducci, L ;
Ku, NN ;
Shivers, S ;
Berman, C ;
Wells, K ;
Rapaport, D ;
Shons, A ;
Horton, J ;
Greenberg, H ;
Nicosia, S ;
Clark, R ;
Cantor, A ;
Reintgen, DS .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (22) :1818-1822
[2]
[Anonymous], 2002, Z1361312000 ANSI INC, P131
[3]
2-PHOTON LASER SCANNING FLUORESCENCE MICROSCOPY [J].
DENK, W ;
STRICKLER, JH ;
WEBB, WW .
SCIENCE, 1990, 248 (4951) :73-76
[4]
Sentinel Lymph Nodes in the Rat: Noninvasive Photoacoustic and US Imaging with a Clinical US System [J].
Erpelding, Todd N. ;
Kim, Chulhong ;
Pramanik, Manojit ;
Jankovic, Ladislav ;
Maslov, Konstantin ;
Guo, Zijian ;
Margenthaler, Julie A. ;
Pashley, Michael D. ;
Wang, Lihong V. .
RADIOLOGY, 2010, 256 (01) :102-110
[5]
Sensitivity of laser opto-acoustic imaging in detection of small deeply embedded tumors [J].
Esenaliev, RO ;
Karabutov, AA ;
Oraevsky, AA .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1999, 5 (04) :981-988
[6]
Real-time optoacoustic monitoring and three-dimensional mapping of a human arm vasculature [J].
Fronheiser, Matthew P. ;
Ermilov, Sergey A. ;
Brecht, Hans-Peter ;
Conjusteau, Andre ;
Su, Richard ;
Mehta, Ketan ;
Oraevsky, Alexander A. .
JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (02)
[7]
LYMPHATIC MAPPING AND SENTINEL LYMPHADENECTOMY FOR BREAST-CANCER [J].
GIULIANO, AE ;
KIRGAN, DM ;
GUENTHER, JM ;
MORTON, DL .
ANNALS OF SURGERY, 1994, 220 (03) :391-401
[8]
On the speckle-free nature of photoacoustic tomography [J].
Guo, Zijian ;
Li, Li ;
Wang, Lihong V. .
MEDICAL PHYSICS, 2009, 36 (09) :4084-4088
[9]
OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[10]
Kim C., J BIOMED OP IN PRESS