Coronary venous imaging with electron beam computed tomographic angiography: Three-dimensional mapping and relationship with coronary arteries

被引:57
作者
Mao, SS [1 ]
Shinbane, JS [1 ]
Girsky, MJ [1 ]
Child, J [1 ]
Carson, S [1 ]
Oudiz, RJ [1 ]
Budoff, MJ [1 ]
机构
[1] Harbor UCLA Med Ctr, Harbor UCLA Res & Educ Inst, Div Cardiol, Torrance, CA 90502 USA
关键词
D O I
10.1016/j.ahj.2004.09.050
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The coronary venous system can provide vascular access for diagnostic and therapeutic procedures. Visualization of the coronary veins and their relationship to other cardiac structures may play an important role in facilitating these procedures. We sought to assess the ability of electron beam computed tomographic angiography (EBCTA) to characterize 3-dimensional (3-D) coronary venous anatomy. Methods Two hundred thirty-one consecutive EBCTA coronary studies were analyzed. The coronary venous system was mapped and analyzed using 2- and 3-D images with definition of diameter and angulations of branch vessels and distance from CS os. Results The coronary sinus (CS), great cardiac, middle cardiac, left ventricular (LV) anterior interventricular, LV marginal, LV posterior, left atrial, and right atrial veins were visualized in 100%, 100%, 100%, 100%, 78%, 81%, 6%, and 8% of the studies, respectively, with definition of diameter and angulations of branch vessels and distance from CS as. There was a significant linear correlation between CS diameter and right atrial end systolic volume (R = 0.244, n = 81, P <.05). No significant correlation existed between CS as diameter and other cardiac size or function parameters. The 3-D spatial arrangements between the coronary veins and the coronary arteries in relation to the epicardium were able to be defined, on the basis of the vessel closer to the epicardium in overlapping segments. Conclusions EBCTA can provide 3-D visualization of most components of the coronary venous system and definition of the spatial relationships with coronary arteries. EBCTA may potentially serve as a useful noninvasive tool for coronary venous imaging,for procedures involving coronary veins, such as resynchronization therapy.
引用
收藏
页码:315 / 322
页数:8
相关论文
共 31 条
[1]   Cardiac resynchronization in chronic heart failure [J].
Abraham, WT ;
Fisher, WG ;
Smith, AL ;
Delurgio, DB ;
Leon, AR ;
Loh, E ;
Kocovic, DZ ;
Packer, M ;
Clavell, AL ;
Hayes, DL ;
Ellestad, M ;
Messenger, J ;
Trupp, RJ ;
Underwood, J ;
Pickering, F ;
Truex, C ;
McAtee, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (24) :1845-1853
[2]  
ALEXANDER R, 1998, HURSTS HEART, P60
[3]   Clinical utility of computed tomography and magnetic resonance techniques for noninvasive coronary angiography [J].
Budoff, MJ ;
Achenbach, S ;
Duerinckx, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (11) :1867-1878
[4]  
BUDOFF MJ, 2004, IN PRESS ACAD RADIOL
[5]   Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay. [J].
Cazeau, S ;
Leclercq, C ;
Lavergne, T ;
Walker, S ;
Varma, C ;
Linde, C ;
Garrigue, S ;
Kappenberger, L ;
Haywood, GA ;
Santini, M ;
Bailleul, C ;
Daubert, JC .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (12) :873-880
[6]   MAJOR CORONARY SINUS ABNORMALITIES - IDENTIFICATION OF OCCURRENCE AND SIGNIFICANCE IN RADIOFREQUENCY ABLATION OF SUPRAVENTRICULAR TACHYCARDIA [J].
CHIANG, CE ;
CHEN, SA ;
YANG, CR ;
CHENG, CC ;
WU, TR ;
TSAI, DS ;
CHIOU, CW ;
CHEN, CY ;
WANG, SP ;
CHIANG, BN ;
CHANG, MS .
AMERICAN HEART JOURNAL, 1994, 127 (05) :1279-1289
[7]  
CLEMENTE CD, 1985, GRAYS ANATOMY HUMAN, P703
[8]  
DOIG JC, 1995, CIRCULATION, V92, P436, DOI 10.1161/01.CIR.92.3.436
[9]   Evaluation of the coronary venous system using electron beam computed tomography [J].
Gerber, TC ;
Sheedy, PF ;
Bell, MR ;
Hayes, DL ;
Rumberger, JA ;
Behrenbeck, T ;
Holmes, DR ;
Schwartz, RS .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 2001, 17 (01) :65-75
[10]   Radiation exposure during cardiac CT: Effective doses at multi-detector row CT and electron-beam CT [J].
Hunold, P ;
Vogt, FM ;
Schmermund, A ;
Debatin, JF ;
Kerkhoff, G ;
Budde, T ;
Erbel, R ;
Ewen, K ;
Barkhausen, J .
RADIOLOGY, 2003, 226 (01) :145-152