Clinical utility of computed tomography and magnetic resonance techniques for noninvasive coronary angiography

被引:90
作者
Budoff, MJ
Achenbach, S
Duerinckx, A
机构
[1] Harbor UCLA Med Ctr, Res & Educ Inst, Div Cardiol, St Johns Cardiovasc Res Ctr, Torrance, CA 90502 USA
[2] Univ Erlangen Nurnberg, Dept Internal Med 2, D-8520 Erlangen, Germany
[3] Univ Texas, SW Med Ctr, Div Radiol, Dallas, TX 75230 USA
关键词
D O I
10.1016/j.jacc.2003.07.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The purpose of this study was to provide a comprehensive review of the literature relating to electron beam angiography (EBA), magnetic resonance angiography, and spiral computed tomography, currently the three most promising noninvasive methods to visualize obstructions in the coronary tree. BACKGROUND Given the high costs and invasiveness of coronary angiography, there is increased interest in noninvasive coronary angiography, which has made great strides to become a clinically useful toot to augment conventional coronary angiography (CCA). METHODS MEDLINE searches were performed to include all articles related to noninvasive angiography utilizing either magnetic resonance imaging (MRI), multi-row detector spiral computed tomography (MDCT), and electron beam tomography (EBT). Weighted analysis was performed to define the published sensitivity and specificity for each technique. RESULTS Electron beam angiography (EBA) provides an overall sensitivity of 87% and specificity of 91% for the detection of obstructive coronary artery disease (CAD). Four-level MDCT data demonstrated an overall sensitivity of 59% and specificity of 89%, with higher accuracy in two recent studies of 16-level detector devices. Magnetic resonance angiography demonstrated sensitivity for detection of obstructive CAD of 77% and specificity of 71%. CONCLUSIONS Noninvasive coronary angiography is a rapidly developing technique and currently not an alternative to. CCA in all cases. All three methods are currently used clinically in certain centers with appropriate expertise. Selective use should prove both cost-effective and provide a safer, less-invasive method for patients to determine the need for medical versus revascularization therapy. (C) 2003 by the American College of Cardiology Foundation.
引用
收藏
页码:1867 / 1878
页数:12
相关论文
共 117 条
[1]   Contrast enhanced electron beam computed tomography to analyse the coronary arteries in patients after acute myocardial infarction [J].
Achenbach, S ;
Ropers, D ;
Regenfus, M ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
HEART, 2000, 84 (05) :489-493
[2]  
Achenbach S, 2000, CIRCULATION, V102, P2823
[3]   Comparison of vessel diameters in electron beam tomography and quantitative coronary angiography [J].
Achenbach, S ;
Moshage, W ;
Ropers, D ;
Bachmann, K .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1998, 14 (01) :1-7
[4]   Curved multiplanar reconstructions for the evaluation of contrast-enhanced electron beam CT of the coronary arteries [J].
Achenbach, S ;
Moshage, W ;
Ropers, D ;
Bachmann, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (04) :895-899
[5]   Noninvasive, three-dimensional visualization of coronary artery bypass grafts by electron beam tomography [J].
Achenbach, S ;
Moshage, W ;
Ropers, D ;
Nossen, J ;
Bachmann, K .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (07) :856-861
[6]   Comparison of image quality in contrast-enhanced coronary artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography [J].
Achenbach, S ;
Giesler, T ;
Ropers, D ;
Ulzheimer, S ;
Anders, K ;
Wenkel, E ;
Pohle, K ;
Kachelriess, M ;
Derlien, H ;
Kalender, WA ;
Daniel, WG ;
Bautz, W ;
Baum, U .
INVESTIGATIVE RADIOLOGY, 2003, 38 (02) :119-128
[7]   Detection of high-grade restenosis after PTCA using contrast-enhanced electron beam CT [J].
Achenbach, S ;
Moshage, W ;
Bachmann, K .
CIRCULATION, 1997, 96 (09) :2785-2788
[8]   Value of electron-beam computed tomography for the noninvasive detection of high-grade coronary-artery stenoses and occlusions [J].
Achenbach, S ;
Moshage, W ;
Ropers, D ;
Nossen, J ;
Daniel, WG .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) :1964-1971
[9]  
Achenbach S, 2001, CIRCULATION, V103, P2535
[10]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463