A fast method for the determination of 16 elements in hair samples by inductively coupled plasma mass spectrometry (ICP-MS) with tetramethylammonium hydroxide solubilization at room temperature

被引:40
作者
Rodrigues, Jairo Lisboa [1 ]
Nunes, Juliana Andrade [1 ]
Batista, Bruno Lemos [1 ]
De Souza, Samuel Simiao [1 ]
Barbosa, Fernando, Jr. [1 ]
机构
[1] USP, Fac Ciencias Farmaceut, Dept Anal Clin Toxicol & Bromatol, Lab Toxicol & Essencial Metais, BR-14040903 Ribeirao Preto, SP, Brazil
关键词
D O I
10.1039/b800595h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a simple and fast method for the determination of Se, Pb, Cd, Mn, Co, Zn, Cu, Pt, U, Tl, As, Mg, Cr, Be, Ag and Ni in hair by using inductively coupled plasma spectrometry (ICP-MS). Prior to analysis, 50-100 mg of hair samples were accurately weighed into (15 mL) conical tubes. Then, 1 mL of 25% m/v tetramethylammonium hydroxide (TMAH) solution was added to the samples, incubated at room temperature overnigh and then further diluted to 10 mL with 1% v/v HNO(3). After that, samples were directly analyzed by ICP-MS (ELAN DRC II). Rhodium was used as internal standard. Calibration was performed with standards containing 1.0 mg mL(-1) of L-cysteine. The method detection limits were 4.0; 0.8; 0.06; 0.8; 0.02; 3.5; 2.3; 0.005; 0.03; 0.02; 0.4; 0.03; 0.09; 0.07; 0.09; 2.0 ng g(-1) for Se, Pb, Cd, Mn, Co, Zn, Cu, Pt, U, Tl, As, Mg, Cr, Be, Ag and Ni, respectively. Method accuracy is traceable to Certified Reference Materials (CRMs) 85 and 86 human hair from the International Atomic Energy Agency (IAEA). Additional validation data are provided based on the analysis of hair samples from the trace elements intercomparison program operated by the Institut National de Sante Publique du Quebec, Canada. With the proposed method at least 500 hair samples can be solubilized and analyzed in 3-4 days.
引用
收藏
页码:992 / 996
页数:5
相关论文
共 22 条
[1]   Determination of total mercury in whole blood by flow injection cold vapor atomic absorption spectrometry with room temperature digestion using tetramethylammonium hydroxide [J].
Barbosa, F ;
Palmer, CD ;
Krug, FJ ;
Parsons, PJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (08) :1000-1005
[2]   A critical review of biomarkers used for monitoring human exposure to lead: Advantages, limitations, and future needs [J].
Barbosa, F ;
Tanus-Santos, JE ;
Gerlach, RF ;
Parsons, PJ .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2005, 113 (12) :1669-1674
[3]   Inter-element interactions in human hair [J].
Chojnacka, K ;
Górecka, H ;
Chojnacki, A ;
Górecki, H .
ENVIRONMENTAL TOXICOLOGY AND PHARMACOLOGY, 2005, 20 (02) :368-374
[4]   Metal and metalloid multi-elementary ICP-MS validation in whole blood, plasma, urine and hair -: Reference values [J].
Goullé, JP ;
Mahieu, L ;
Castermant, J ;
Neveu, N ;
Bonneau, L ;
Lainé, G ;
Bouige, D ;
Lacroix, C .
FORENSIC SCIENCE INTERNATIONAL, 2005, 153 (01) :39-44
[5]   CONTRIBUTIONS TO THE CHEMISTRY OF HUMAN-HAIR .1. ANALYSES OF CYSTINE, CYSTEINE AND CYSTINE OXIDES IN UNTREATED HUMAN-HAIR [J].
HILTERHAUSBONG, S ;
ZAHN, H .
INTERNATIONAL JOURNAL OF COSMETIC SCIENCE, 1987, 9 (03) :101-109
[6]  
Jolles P, 1996, FORMATION STRUCTURE
[7]   Direct multielement determination of human hair by induction-heating electrothermal vaporization with ICP-MS [J].
Lam, Rebecca ;
Salin, Eric D. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (11) :1430-1433
[8]   Comparison of ultrasound-assisted extraction, slurry sampling and microwave-assisted digestion for cadmium, copper and lead determination in biological and sediment samples by electrothermal atomic absorption spectrometry [J].
Lima, ÉC ;
Barbosa, F ;
Krug, FJ ;
Silva, MM ;
Vale, MGR .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (08) :995-1000
[9]   How reliable are human hair reference intervals for trace elements? [J].
Miekeley, N ;
Carneiro, MTWD ;
da Silveira, CLP .
SCIENCE OF THE TOTAL ENVIRONMENT, 1998, 218 (01) :9-17
[10]   Simple direct method for the determination of total mercury levels in blood and urine and nitric acid digests of fish by inductively coupled plasma mass spectrometry [J].
Moreton, JA ;
Delves, HT .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (07) :659-665