Determination of total mercury in whole blood by flow injection cold vapor atomic absorption spectrometry with room temperature digestion using tetramethylammonium hydroxide

被引:42
作者
Barbosa, F
Palmer, CD
Krug, FJ
Parsons, PJ
机构
[1] New York State Dept Hlth, Wadsworth Ctr Labs & Res, Albany, NY 12201 USA
[2] SUNY Albany, Sch Publ Hlth, Dept Environm Hlth & Toxicol, Albany, NY 12201 USA
[3] Univ Sao Paulo, Ctr Energia Nucl Agr, BR-13400970 Piracicaba, SP, Brazil
关键词
D O I
10.1039/b400315b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An improved method is described for the determination of total Hg in whole blood based on flow injection cold vapor atomic absorption spectrometry (FI-CVAAS). Aliquots of whole blood (300 mul) are diluted 1 + 1 v/v with 10% v/v tetramethylammonium hydroxide ( TMAH) solution, incubated for 1 h at room temperature and then further diluted 1 + 4 v/v with 2% v/v HCl. The TMAH approach is directly compared to a previously published method that utilizes an on-line microwave-assisted heating step as part of the FI arrangement. Thus, the key issue addressed here is the elimination of the on-line microwave digestion step from the FI manifold, because of problems observed with precipitation in the reaction coil and high back pressure in FI manifold. Matrix-matched calibration standards are used and the method detection limit (3sigma) is 0.2 mug l(-1). Method accuracy is traceable to Standard Reference Material (SRM) 966 Toxic Metals in Bovine Blood from the National Institute of Standards and Technology (NIST). Additional validation data are provided based on the analysis of whole blood materials from the New York State Department of Health's Proficiency Testing Program for Trace Elements and from the trace elements intercomparison program operated by the Institut National de Sante Publique du Quebec, Canada. Accuracy (-2.5%) and precision (<6.0% repeatability and <10% intermediate precision) of the TMAH method compare favorably with values obtained for the on-line microwave method (<10.0% repeatability and <15% reproducibility), and the TMAH method is essentially free of the disadvantages associated with the latter method.
引用
收藏
页码:1000 / 1005
页数:6
相关论文
共 26 条
[1]   AUTOMATED-DETERMINATION OF INORGANIC MERCURY IN BLOOD AFTER SULFURIC-ACID TREATMENT USING COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRY AND AN INDUCTIVELY HEATED GOLD TRAP [J].
BERGDAHL, IA ;
SCHUTZ, A ;
HANSSON, GA .
ANALYST, 1995, 120 (04) :1205-1209
[2]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Determination of methylmercury and inorganic mercury in whole blood by headspace, cryofocusing gas chromatography and atomic absorption spectrometry [J].
Brunetto, MR ;
Luna, JR ;
Zambrano, A ;
Gallignani, M ;
Burguera, M ;
Burguera, JL ;
de Peña, YP .
ANALYST, 1999, 124 (10) :1493-1499
[5]   Microwave-assisted sample decomposition in flow analysis [J].
Burguera, M ;
Burguera, JL .
ANALYTICA CHIMICA ACTA, 1998, 366 (1-3) :63-80
[6]  
Chen HP, 1998, ATOM SPECTROSC, V19, P176
[7]   On-line pre-concentration of Hg in blood and urine and determination by CVAAS [J].
Dressler, VL ;
Flores, ÉMM ;
Pozebon, D ;
Kaercher, LE .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (08) :790-793
[8]   A time-based flow injection cold vapor atomic absorption spectrometry system with on-line microwave sample pre-treatment for the determination of inorganic and total mercury in urine [J].
Gallignani, M ;
Bahsas, H ;
Brunetto, MR ;
Burguera, M ;
Burguera, JL ;
de Peña, YP .
ANALYTICA CHIMICA ACTA, 1998, 369 (1-2) :57-67
[9]   DETERMINATION OF MERCURY IN URINE BY FLOW-INJECTION COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRY [J].
GUO, TZ ;
BAASNER, J .
ANALYTICA CHIMICA ACTA, 1993, 278 (01) :189-196
[10]   ONLINE MICROWAVE SAMPLE PRETREATMENT FOR THE DETERMINATION OF MERCURY IN BLOOD BY FLOW-INJECTION COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRY [J].
GUO, TZ ;
BAASNER, J .
TALANTA, 1993, 40 (12) :1927-1936