On-line pre-concentration of Hg in blood and urine and determination by CVAAS

被引:23
作者
Dressler, VL [1 ]
Flores, ÉMM
Pozebon, D
Kaercher, LE
机构
[1] Univ Fed Santa Maria, Dept Quim, BR-97150900 Santa Maria, RS, Brazil
[2] Univ Fed Rio Grande do Sul, Inst Quim, BR-91501970 Porto Alegre, RS, Brazil
关键词
D O I
10.1039/b203161b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for total Hg determination in urine and blood by cold vapour atomic absorption spectrometry (CVAAS), after on-line separation/pre-concentration, is described. The samples were acid-digested in closed vessels using a HNO3/HClO4 mixture and heating in a microwave oven. The Hg determination was accomplished by retention of Hg complexes formed with the ammonium salt of O,O-diethyldithiophosphoric acid (DDTP) on C-18 immobilized on silica in a column. The analyte was eluted with methanol, which was mixed with a reducing agent (NaBH4) on-line, and measured. The optimum conditions for the Hg pre-concentration, such as DDTP concentration, acid concentration and acid nature (HNO3 and HCl), and the solutions flow rates were experimentally established. The conditions for on-line cold vapour generation, including the acid concentration in the eluant (methanol), the NaBH4 concentration and the carrier gas (Ar) flow rate, were optimised. The limit of detection (LOD), based on three times the standard deviation of the sample blank (10 consecutive measurements), of the proposed method was 8 ng l(-1) of Hg (by processing 7.6 ml of solution) and the LOD for Hg in the samples was 20 ng l(-1). At a concentration of 50 ng l(-1) of Hg solution, the relative standard deviation was less than 6% for five replicates of the sample solution or calibration solution. The calibration curves were linear from 25 ng l(-1) to 600 ng l(-1) of Hg and a sample throughput of 24 measurements per hour was possible. The accuracy of the method was checked by analysis of a certified urine sample and spiked blood samples. The proposed method was employed for analysis of real blood and urine samples.
引用
收藏
页码:790 / 793
页数:4
相关论文
共 19 条
[1]   WHAT CONTRIBUTION CAN BE MADE TO BIOLOGICAL MONITORING BY HAIR ANALYSIS .1. [J].
BENCZE, K .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 337 (08) :867-876
[2]   THE ASSESSMENT OF REFERENCE VALUES FOR ELEMENTS IN HUMAN BIOLOGICAL TISSUES AND FLUIDS - A SYSTEMATIC REVIEW [J].
CAROLI, S ;
ALIMONTI, A ;
CONI, E ;
PETRUCCI, F ;
SENOFONTE, O ;
VIOLANTE, N .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1994, 24 (5-6) :363-398
[3]   Trace determination of mercury: A review [J].
Clevenger, WL ;
Smith, BW ;
Winefordner, JD .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1997, 27 (01) :1-26
[4]   Determination of heavy metals by inductively coupled plasma mass spectrometry after on-line separation and preconcentration [J].
Dressler, VL ;
Pozebon, D ;
Curtius, AJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (11) :1527-1539
[5]   A time-based flow injection cold vapor atomic absorption spectrometry system with on-line microwave sample pre-treatment for the determination of inorganic and total mercury in urine [J].
Gallignani, M ;
Bahsas, H ;
Brunetto, MR ;
Burguera, M ;
Burguera, JL ;
de Peña, YP .
ANALYTICA CHIMICA ACTA, 1998, 369 (1-2) :57-67
[6]   ONLINE PRECONCENTRATION OF INORGANIC MERCURY AND METHYLMERCURY IN SEA-WATER BY SORBENT EXTRACTION AND TOTAL MERCURY DETERMINATION BY COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRY [J].
GARCIA, MF ;
GARCIA, RP ;
GARCIA, NB ;
SANZMEDEL, A .
TALANTA, 1994, 41 (11) :1833-1839
[7]   Determination of mercury in saliva with a flow-injection system [J].
Guo, T ;
Baasner, J ;
Gradl, M ;
Kistner, A .
ANALYTICA CHIMICA ACTA, 1996, 320 (2-3) :171-176
[8]   ONLINE MICROWAVE SAMPLE PRETREATMENT FOR THE DETERMINATION OF MERCURY IN BLOOD BY FLOW-INJECTION COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRY [J].
GUO, TZ ;
BAASNER, J .
TALANTA, 1993, 40 (12) :1927-1936
[9]   DETERMINATION OF TOTAL MERCURY IN WATERS AND URINE BY FLOW-INJECTION ATOMIC-ABSORPTION SPECTROMETRY PROCEDURES INVOLVING ONLINE AND OFF-LINE OXIDATION OF ORGANOMERCURY SPECIES [J].
HANNA, CP ;
TYSON, JF ;
MCINTOSH, S .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :653-656
[10]   Selective pre-concentration and solid phase extraction of mercury(II) from natural water by silica gel-loaded dithizone phases [J].
Mahmoud, ME ;
Osman, MM ;
Amer, ME .
ANALYTICA CHIMICA ACTA, 2000, 415 (1-2) :33-40