Radiation characteristics of helical tomotherapy

被引:164
作者
Jeraj, R
Mackie, TR
Balog, J
Olivera, G
Pearson, D
Kapatoes, J
Ruchala, K
Reckwerdt, P
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[2] TomoTherapy Inc, Madison, WI 53717 USA
[3] Jozef Stefan Inst, SI-1000 Ljubljana, Slovenia
关键词
Monte Carlo simulations; helical tomotherapy; beam characteristics;
D O I
10.1118/1.1639148
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Helical tomotherapy is a dedicated intensity modulated radiation therapy (IMRT) system with on-board imaging capability (MVCT) and therefore differs from conventional treatment units. Different design goals resulted in some distinctive radiation field characteristics. The most significant differences in the design are the lack of flattening filter, increased shielding of the collimators, treatment and imaging operation modes and narrow fan beam delivery. Radiation characteristics of the helical tomotherapy system, sensitivity studies of various incident electron beam parameters and radiation safety analyses are presented here. It was determined that the photon beam energy spectrum of helical tomotherapy is similar to that of more conventional radiation treatment units. The two operational modes of the system result in different nominal energies of the incident electron beam with approximately 6 MeV and 3.5 MeV in the treatment and imaging modes, respectively. The off-axis mean energy dependence is much lower than in conventional radiotherapy units with less than 5% variation across the field, which is the consequence of the absent flattening filter. For the same reason the transverse profile exhibits the characteristic conical shape resulting in a 2-fold increase of the beam intensity in the center. The radiation leakage outside the field was found to be negligible at less than 0.05% because of the increased shielding of the collimators. At this level the in-field scattering is a dominant source of the radiation outside the field and thus a narrow field treatment does not result in the increased leakage. The sensitivity studies showed increased sensitivity on the incident electron position because of the narrow fan beam delivery and high sensitivity on the incident electron energy, as common to other treatment systems. All in all, it was determined that helical tomotherapy is a system with some unique radiation characteristics, which have been to a large extent optimized for intensity modulated delivery. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:396 / 404
页数:9
相关论文
共 37 条
[1]   Using Monte Carlo methods to commission electron beams: A feasibility study [J].
Antolak, JA ;
Bieda, MR ;
Hogstrom, KR .
MEDICAL PHYSICS, 2002, 29 (05) :771-786
[2]   PENELOPE - AN ALGORITHM FOR MONTE-CARLO SIMULATION OF THE PENETRATION AND ENERGY-LOSS OF ELECTRONS AND POSITRONS IN MATTER [J].
BARO, J ;
SEMPAU, J ;
FERNANDEZVAREA, JM ;
SALVAT, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 100 (01) :31-46
[3]   The effect of scattering foil parameters on electron-beam Monte Carlo calculations [J].
Bieda, MR ;
Antolak, JA ;
Hogstrom, KR .
MEDICAL PHYSICS, 2001, 28 (12) :2527-2534
[4]  
Briesmeister JF, 1999, LA12625 LOS AL NAT L
[5]   MONTE-CARLO STUDY OF ACCELERATOR HEAD SCATTER [J].
CHANEY, EL ;
CULLIP, TJ ;
GABRIEL, TA .
MEDICAL PHYSICS, 1994, 21 (09) :1383-1390
[6]  
Company F. Z., 1996, Australasian Physical and Engineering Sciences in Medicine, V19, P217
[7]   Photon beam characterization and modelling for Monte Carlo treatment planning [J].
Deng, J ;
Jiang, SB ;
Kapur, A ;
Li, JS ;
Pawlicki, T ;
Ma, CM .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (02) :411-427
[8]   Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: results of Monte Carlo simulations for a Varian 2100EX accelerator [J].
Ding, GX .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (07) :1025-1046
[9]  
EBERT MA, 1996, PHYS ENG SCI MED, V19, P131
[10]   The flatness of Siemens linear accelerator x-ray fields [J].
Faddegon, BA ;
O'Brien, P ;
Mason, DLD .
MEDICAL PHYSICS, 1999, 26 (02) :220-228