Accuracy of cone beam computed tomography in assessing peri-implant bone defect regeneration: a histologically controlled study in dogs

被引:53
作者
Fienitz, Tim [2 ]
Schwarz, Frank [2 ]
Ritter, Lutz [1 ]
Dreiseidler, Timo [1 ]
Becker, Juergen [2 ]
Rothamel, Daniel [1 ]
机构
[1] Univ Hosp Cologne, Dept Craniomaxillofacial & Plast Surg, D-50931 Cologne, Germany
[2] Univ Dusseldorf, Dept Oral Surg, D-40225 Dusseldorf, Germany
关键词
animal experiments; bone regeneration; bone substitutes; CT imaging; guided tissue regeneration; GEOMETRIC ACCURACY; IMAGE QUALITY; IN-VITRO; RELIABILITY; CT; TOOTH;
D O I
10.1111/j.1600-0501.2011.02232.x
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
Objective: To assess the accuracy of cone-beam computed tomography (CBCT) in terms of buccal bone-wall configuration and peri-implant bone defect regeneration after guided bone regeneration (GBR). Material and methods: Titanium implants were inserted into standardized box-shaped defects in the mandible of 12 foxhounds. Defects of one side were augmented following the principle of GBR, while the other side was left untreated. Radiological evaluation was performed using CBCT and compared with histomorphometrical measurements of the respective site serving as a validation method. Results: Non-augmented control sites providing a horizontal bone width (BW) of<0.5 mm revealed a significantly lower accuracy between the radiological and the histological evaluation of the buccal defect depth (1.93 +/- 1.59 mm) compared with the group providing a BW of >0.5 mm (0.7 +/- 0.7 mm) (P<0.05, MannWhitney U-test). In GBR-treated defects, the subgroup <0.5 mm (1.49 +/- 1.29 mm) revealed a significantly higher difference between CBCT and histology compared with >0.5 mm (0.82 +/- 1.07) (P>0.05, MannWhitney U-test). However, a radiological discrimination between original bone, integrated and non-integrated bone substitute material was not reliable. Additionally, it was found that a minimum buccal BW of 0.5 mm was necessary for the detection of bone in radiology. Conclusion: The evaluation of peri-implant bone defect regeneration by means of CBCT is not accurate for sites providing a BW of <0.5 mm. Moreover, a safe assessment of the success of the GBR technique is not possible after the application of a radiopaque bone substitute material. To cite this article:?Fienitz T, Schwarz F, Ritter L, Dreiseidler T, Becker J, Rothamel D. Accuracy of cone beam computed tomography in assessing peri-implant bone defect regeneration: a histologically controlled study in dogs.?Clin. Oral Impl. Res. 23, 2012; 882887.?doi: 10.1111/j.1600-0501.2011.02232.x
引用
收藏
页码:882 / 887
页数:6
相关论文
共 26 条
[1]
DIRECT BONE ANCHORAGE OF DENTAL IMPLANTS [J].
ALBREKTSSON, T .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (02) :255-261
[2]
HEALING OF BONE DEFECTS BY GUIDED TISSUE REGENERATION [J].
DAHLIN, C ;
LINDE, A ;
GOTTLOW, J ;
NYMAN, S .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1988, 81 (05) :672-676
[3]
Danforth Robert A, 2003, J Calif Dent Assoc, V31, P847
[4]
Davies JE, 1998, INT J PROSTHODONT, V11, P391
[5]
Beam hardening artefacts occur in dental implant scans with the NewTom® cone beam CT but not with the dental 4-row multidetector CT [J].
Draenert, F. G. ;
Coppenrath, E. ;
Herzog, P. ;
Muller, S. ;
Mueller-Lisse, U. G. .
DENTOMAXILLOFACIAL RADIOLOGY, 2007, 36 (04) :198-203
[6]
Dreiseidler T, 2009, INT J ORAL MAX IMPL, V24, P216
[7]
THE EFFECT OF MAS VARIATION UPON COMPUTED-TOMOGRAPHY IMAGE QUALITY AS EVALUATED BY INVIVO AND INVITRO STUDIES [J].
HAAGA, JR ;
MIRALDI, F ;
MACINTYRE, W ;
LIPUMA, JP ;
BRYAN, PJ ;
WIESEN, E .
RADIOLOGY, 1981, 138 (02) :449-454
[8]
Osseous abnormalities of the mandibular condyle: diagnostic reliability of cone beam computed tomography compared with helical computed tomography based on an autopsy material [J].
Honda, K. ;
Larheim, T. A. ;
Maruhashi, K. ;
Matsumoto, K. ;
Iwai, K. .
DENTOMAXILLOFACIAL RADIOLOGY, 2006, 35 (03) :152-157
[9]
Accuracy and reliability of cone-beam computed tomography for measuring alveolar bone height and detecting bony dehiscences and fenestrations [J].
Leung, Cynthia C. ;
Palomo, Leena ;
Griffith, Richard ;
Hans, Mark G. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (04) :S109-S119
[10]
Assessment of bone segmentation quality of cone-beam CT versus multislice spiral CT: a pilot study [J].
Loubele, Miet ;
Maes, Frederik ;
Schutyser, Filip ;
Marchal, Guy ;
Jacobs, Reinhilde ;
Suetens, Paul .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2006, 102 (02) :225-234