Impact of hemocontrol on hypertension, nursing interventions, and quality of life:: A randomized, controlled trial

被引:31
作者
Deziel, Clement [1 ]
Bouchard, Josee [1 ]
Zellweger, Michael [1 ]
Madore, Francois [1 ]
机构
[1] Hop Sacre Coeur, Res Ctr, Div Nephrol, Montreal, PQ H4J 1C5, Canada
来源
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY | 2007年 / 2卷 / 04期
关键词
D O I
10.2215/CJN.04171206
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background: Volume overload contributes to the pathogenesis of hypertension in hemodialysis (HD) patients. Design, setting, participants, and measurements: The Hemocontrol (HC) system (Gambro), which automatically adjusts ultrafiltration rate and dialysate conductivity during dialysis, has been suggested to improve hemodynamic tolerance and thereby facilitate fluid removal. A 6-mo randomized, controlled trial was performed to test the hypothesis that the addition of the HC system to a systematic BP management protocol may lower home BP in comparison with standard HD as primary end point. Secondary end points were the number of nursing interventions during dialysis and health-related quality of life. Results: Complete BP data were available for 36 of the 44 patients who completed the trial. There was a statistically significant overall decrease in systolic BP during the study period (P = 0.005). However, the difference between the HC group and the standard HD group was NS (HC: from 147.8 +/- 21.7 to 139.8 +/- 16.2 mmHg; standard HD: from 141.9 +/- 19.2 to 135.2 +/- 9.9 mmHg). The number of HD sessions that required nursing interventions decreased in the HC group, whereas it increased in the standard HD group (HC: 42.9% reduction; standard HD: 35.7% increase; P = 0.04). There was also a significant improvement in health-related quality of life in the HC group but not in the standard HD group. Conclusions: These results suggest that the addition of the HC system to a systematic BP management protocol provides no additional benefit with regard to BP reduction. However, the HC system may improve the patient tolerability to dialysis.
引用
收藏
页码:661 / 668
页数:8
相关论文
共 31 条
[1]
Home blood pressure monitoring improves the diagnosis of hypertension in hemodialysis patients [J].
Agarwal, R ;
Andersen, MJ ;
Bishu, K ;
Saha, C .
KIDNEY INTERNATIONAL, 2006, 69 (05) :900-906
[2]
Assessment of blood pressure in hemodialysis patients [J].
Agarwal, R .
SEMINARS IN DIALYSIS, 2002, 15 (05) :299-304
[4]
Pre- and postdialysis blood pressures are imprecise estimates of interdialytic ambulatory blood pressure [J].
Agarwal, Rajiv ;
Peixoto, Aldo J. ;
Santos, Sergio F. F. ;
Zoccali, Carmine .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2006, 1 (03) :389-398
[6]
Seasonal changes in blood pressure in patients with end-stage renal disease treated with hemodialysis [J].
Argilés, A ;
Mourad, G ;
Mion, C .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (19) :1364-1370
[7]
Should relative blood volume changes be routinely measured during the dialysis session? [J].
Basile, C .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2001, 16 (01) :10-12
[8]
Efficacy and safety of haemodialysis treatment with the Hemocontrol™ biofeedback system:: a prospective medium-term study [J].
Basile, C ;
Giordano, R ;
Vernaglione, L ;
Montanaro, A ;
De Maio, P ;
De Padova, F ;
Marangi, AL ;
Di Marco, L ;
Santese, D ;
Semeraro, A ;
Ligorio, VA .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2001, 16 (02) :328-334
[9]
Biofeedback regulation of ultrafiltration and dialysate conductivity for the prevention of hypotension during hemodialysis [J].
Bégin, V ;
Déziel, C ;
Madore, F .
ASAIO JOURNAL, 2002, 48 (03) :312-315
[10]
SURVIVAL AS AN INDEX OF ADEQUACY OF DIALYSIS [J].
CHARRA, B ;
CALEMARD, E ;
RUFFET, M ;
CHAZOT, C ;
TERRAT, JC ;
VANEL, T ;
LAURENT, G .
KIDNEY INTERNATIONAL, 1992, 41 (05) :1286-1291