Cryogenically cooled microloop system for sampling and injection in fast GC

被引:21
作者
Borgerding, AJ [1 ]
Wilkerson, CW [1 ]
机构
[1] LOS ALAMOS NATL LAB,CHEM SCI & TECHNOL DIV,LOS ALAMOS,NM 87545
关键词
D O I
10.1021/ac950853n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new inlet system for fast gas chromatography has been built in which analyte compounds in the gas phase are cryogenically trapped onto a sample loop, isolated, revaporized, and injected. Sample loops are constructed of 20 cm lengths of 50 and 100 mu m i.d. fused-silica tubing. Since the volume of these loops is small, analytes could be injected with initial bandwidths of less than 10 ms. Loops can be coated to increase the effectiveness with which compounds are trapped. Simple loops with thicker, less polar films trap hydrocarbons at relatively higher temperatures than those with more polar, thinner films. Use of 50 mu m i.d. sample loops results in narrower injection bandwidths compared to 100 Irm i.d. loops, but this does not necessarily translate into better chromatographic resolution. The wider bore tubes allow for more efficient sampling and shorter retention times for similar column head pressures. The injection system has been used to demonstrate sampling and fast GC analysis of a 10 ppbV mixture of volatile organic compounds.
引用
收藏
页码:701 / 707
页数:7
相关论文
共 28 条
[21]  
RANKIN C, 1990, HRC-J HIGH RES CHROM, V13, P674
[22]   FAST FLUIDIC LOGIC INJECTION AT PRESSURES UP TO 25 BAR IN HIGH-SPEED CAPILLARY GAS-CHROMATOGRAPHY [J].
SCHUTJES, CPM ;
CRAMERS, CA ;
VIDALMADJAR, C ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHY, 1983, 279 (NOV) :269-277
[23]   PRACTICAL ASPECTS OF FAST GAS-CHROMATOGRAPHY ON 50 MU-M ID CAPILLARY COLUMNS - COMBINATION WITH ELECTRON-CAPTURE DETECTION [J].
SCHUTJES, CPM ;
VERMEER, EA ;
SCHERPENZEEL, GJ ;
BALLY, RW ;
CRAMERS, CA .
JOURNAL OF CHROMATOGRAPHY, 1984, 289 (APR) :157-162
[24]   INCREASED SPEED OF ANALYSIS IN ISOTHERMAL AND TEMPERATURE-PROGRAMMED CAPILLARY GAS-CHROMATOGRAPHY BY REDUCTION OF THE COLUMN INNER DIAMETER [J].
SCHUTJES, CPM ;
VERMEER, EA ;
RIJKS, JA ;
CRAMERS, CA .
JOURNAL OF CHROMATOGRAPHY, 1982, 253 (01) :1-16
[25]   THEORETICAL ASPECTS AND PRACTICAL POTENTIALS OF RAPID GAS-ANALYSIS IN CAPILLARY GAS-CHROMATOGRAPHY [J].
TIJSSEN, R ;
VANDENHOED, N ;
VANKREVELD, ME .
ANALYTICAL CHEMISTRY, 1987, 59 (07) :1007-1015
[26]   SAMPLE INTRODUCTION IN HIGH-SPEED CAPILLARY GAS-CHROMATOGRAPHY - INPUT BANDWIDTH AND DETECTION LIMITS [J].
VANES, A ;
JANSSEN, J ;
BALLY, R ;
CRAMERS, C ;
RIJKS, J .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (05) :273-279
[27]   SAMPLE ENRICHMENT IN HIGH-SPEED NARROW BORE CAPILLARY GAS-CHROMATOGRAPHY [J].
VANES, A ;
JANSSEN, J ;
CRAMERS, C ;
RIJKS, J .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (12) :852-857
[28]   A HIGH-SPEED GAS-CHROMATOGRAPH COUPLED TO A TIME-OF-FLIGHT MASS ANALYZER [J].
WOLLNIK, H ;
BECKER, R ;
GOTZ, H ;
KRAFT, A ;
JUNG, H ;
CHEN, CC ;
VANYSACKER, PG ;
JANSEN, HG ;
SNIJDERS, HMJ ;
LECLERCQ, PA ;
CRAMER, CA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 130 (03) :L7-L11