Inadvertent retention of angled drill guides after volar locking plate fixation of distal radial fractures

被引:14
作者
Bhattacharyya, Timothy [1 ,2 ]
Wadgaonkar, Ajay D. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Orthopaed Traumat Surg, Boston, MA 02118 USA
[2] Brigham & Womens Hosp, Boston, MA 02115 USA
关键词
D O I
10.2106/JBJS.G.00939
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Advances in locking plate technology have proven especially valuable for fixation of distal radial fractures, and preliminary results have been excellent(1-6). However, new technology can sometimes lead to new complications. In some systems, the locking plates are preloaded with angled drill guides to allow for easy placement of locking screws in the proper direction (Fig. 1). The drill guides are designed to be removed prior to closure. We report the cases of three patients in whom the angled drill guides were retained after surgery. Institutional review board approval was obtained for this study, and the patients were informed that data concerning the case would be submitted for publication, and they consented.
引用
收藏
页码:401 / 403
页数:3
相关论文
共 16 条
[1]
Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures [J].
Al-Rashid, M. ;
Theivendran, K. ;
Craigen, M. A. C. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (12) :1610-1612
[2]
Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate [J].
Arora, Rohit ;
Lutz, Martin ;
Hennerbichler, Alfred ;
Krappinger, Dietinar ;
Espen, David ;
Gabl, Markus .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (05) :316-322
[3]
Treatment of unstable distal radial fractures with the volar locking plating system [J].
Chung, Kevin C. ;
Watt, Andrew J. ;
Kotsis, Sandra V. ;
Margaliot, Zvi ;
Haase, Steven C. ;
Kim, Myra .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (12) :2687-2694
[4]
Constantine KJ, 2002, ORTHOPEDICS, V25, P125
[5]
Osteosynthesis of distal radial fractures with a volar locking screw plate system [J].
Drobetz, H ;
Kutscha-Lissberg, E .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (01) :1-6
[6]
DELAYED RUPTURE OF FLEXOR POLLICIS LONGUS TENDON AFTER VOLAR PLATING OF THE DISTAL RADIUS [J].
Koo, Siu Cheong ;
Ho, Sheung Tung .
JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2006, 11 (1-2) :67-70
[7]
Plating for distal radius fractures [J].
Martineau, Paul A. ;
Berry, Gregory K. ;
Harvey, Edward J. .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2007, 38 (02) :193-+
[8]
Surgical treatment of unstable distal radius fractures with volar locking plates [J].
Murakami, Kenichi ;
Abe, Yoshihiro ;
Takahashi, Kazuhisa .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2007, 12 (02) :134-140
[9]
Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates [J].
Musgrave, DS ;
Idler, RS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (04) :743-749
[10]
Orbay J L, 2000, Hand Surg, V5, P103, DOI 10.1142/S0218810400000223