Plating for distal radius fractures

被引:32
作者
Martineau, Paul A.
Berry, Gregory K.
Harvey, Edward J.
机构
[1] McGill Univ, Div Orthopaed Surg, Montreal, PQ, Canada
[2] Univ Washington, Seattle, WA 98195 USA
关键词
D O I
10.1016/j.ocl.2007.01.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
No area of fracture management has had such a recent explosion of new treatment modalities as distal radius plating. This explosion has largely been implant- and industry-driven, with little evidence-based research guiding the way. A perceived difficulty with commonly used modalities by the orthopedic community has been enough to drive an entire new set of options for distal radius fixation. A drift from dorsal to volar plating has occurred that has been unexamined by randomized research. Segment specific fixation has been a new mindset that has resulted in a novel plate line and has caused other manufacturers to redesign their product lines. Other novel approaches for proposed problems include locking plates, nail-plate combinations, and others. This article outlines some of these options with a literature opinion and a clarification from the authors. A treatment plan for common fractures of the distal radius is also outlined.
引用
收藏
页码:193 / +
页数:10
相关论文
共 49 条
[1]
[Anonymous], 2003, COCHRANE DB SYST REV
[2]
Two potential causes of EPL rupture after distal radius volar plate fixation [J].
Benson, Eric C. ;
DeCarvalho, Alex ;
Mikola, Elizabeth A. ;
Veitch, John M. ;
Moneim, Moheb S. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (451) :218-222
[3]
The outcome of intra-articular distal radius fractures treated with fragment-specific fixation [J].
Benson, Leon S. ;
Minihane, Keith P. ;
Stern, Laura D. ;
Eller, Erik ;
Seshadri, Roopa .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (08) :1333-1339
[4]
Does Kapandji wiring help in older patients? A retrospective comparative review of displaced intra-articular distal radial fractures in patients over 55 years [J].
Board, T ;
Kocialkowski, A ;
Andrew, G .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1999, 30 (10) :663-669
[5]
Internal fixation of distal radius fractures with novel intramedullary implants [J].
Brooks, Kenneth R. ;
Capo, John T. ;
Warburton, Mark ;
Tan, Virak .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (445) :42-50
[6]
Burke E F, 1998, Tech Hand Up Extrem Surg, V2, P248, DOI 10.1097/00130911-199812000-00004
[7]
Open reduction and internal fixation of intra articular and unstable fractures of the distal radius using the AO distal radius plate [J].
Campbell, DA .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2000, 25B (06) :528-534
[8]
Effects of implant material and plate design on tendon function and morphology [J].
Cohen, Mark S. ;
Turner, Thomas M. ;
Urban, Robert M. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (445) :81-90
[9]
A biomechanical comparison of fragment-specific fixation and augmented external fixation for intra-articular distal radius fractures [J].
Dodds, SD ;
Cornelissen, S ;
Jossan, S ;
Wolfe, SW .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2002, 27A (06) :953-964
[10]
Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction - A biomechanic study in a cadaveric model [J].
Drobetz, H ;
Bryant, AL ;
Pokorny, T ;
Spitaler, R ;
Leixnering, M ;
Jupiter, JB .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (04) :615-622