Effects of implant material and plate design on tendon function and morphology

被引:24
作者
Cohen, Mark S. [1 ]
Turner, Thomas M. [1 ]
Urban, Robert M. [1 ]
机构
[1] Rush Univ, Med Ctr, Dept Orthopaed Surg, Chicago, IL USA
关键词
D O I
10.1097/01.blo.0000205894.98361.29
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Titanium implants are an alternative to stainless steel implants for internal fixation after fracture. The advantages of titanium include decreased implant stiffness, increased biocompatibility, and diminished stress shielding. However, titanium has been implicated in tendon irritation and adhesions when used in the hand and wrist. We evaluated the relationship between extensor tendon morphology and dorsal plating of the distal radius in a canine model using distal radius pi plates made of stainless steel, titanium, and titanium alloy with a modified ramped edge design. We found marked histologic changes in the tendons and surrounding soft tissues including tendon deformation and degeneration (fibrillation, cartilage metaplasia, hypocellularity and hyalinization of blood vessels), peritendonous adhesions and neovascularity in the parenchyma. Only a minimal inflammatory cell infiltrate was identified and was limited to the tenosynovium and/or paratenon. No differences were identified between titanium and stainless steel implants and those with a ramped design. Although all animals lost wrist motion with time, no differences were observed between groups. Our results suggest that pi plate placement on the dorsal surface of the distal radius may lead to extensor tendon irritation and dysfunction. There is no evidence to suggest that this is specifically related to titanium or plate edge design.
引用
收藏
页码:81 / 90
页数:10
相关论文
共 20 条
[1]
[Anonymous], 1986, HDB BIOMATERIAL EVAL
[2]
Influence of materials for fixation implants on local infection - An experimental study of steel versus titanium DCP in rabbits [J].
Arens, S ;
Schlegel, U ;
Printzen, G ;
Ziegler, WJ ;
Perren, SM ;
Hansis, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (04) :647-651
[3]
BIOMATERIAL-CENTERED INFECTION - MICROBIAL ADHESION VERSUS TISSUE INTEGRATION [J].
GRISTINA, AG .
SCIENCE, 1987, 237 (4822) :1588-1595
[4]
Internal fixation of distal radius fractures with dorsal dislocation:: π-plate or two 1/4 tube plates?: A prospective randomized study [J].
Hahnloser, D ;
Platz, A ;
Amgwerd, M ;
Trentz, O .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1999, 47 (04) :760-765
[5]
Metal sensitivity in patients with orthopaedic implants [J].
Hallab, N ;
Merritt, K ;
Jacobs, JJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (03) :428-436
[6]
Detection of titanium in human tissues after craniofacial surgery [J].
Jorgenson, DS ;
Mayer, MH ;
Ellenbogen, RG ;
Centeno, JA ;
Johnson, FB ;
Mullick, FG ;
Manson, PN .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 99 (04) :976-979
[7]
Complications of the AO/ASIF titanium distal radius plate system (π plate) in internal fixation of the distal radius:: A brief report [J].
Kambouroglou, GK ;
Axelrod, TS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (04) :737-741
[8]
Kane Kevin R., 1994, Contemporary Orthopaedics, V28, P249
[9]
Immuno-inflammatory responses in the tissue adjacent to titanium miniplates used in the treatment of mandibular fractures [J].
Katou, F ;
Andoh, N ;
Motegi, K ;
Nagura, H .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1996, 24 (03) :155-162
[10]
Tissue response to titanium plates: A transmitted electron microscopic study [J].
Kim, YK ;
Yeo, HH ;
Lim, SC .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1997, 55 (04) :322-326