Safety and adequacy of renal transplant protocol biopsies

被引:237
作者
Schwarz, A [1 ]
Gwinner, W
Hiss, M
Radermacher, J
Mengel, M
Haller, H
机构
[1] Hannover Med Sch, Dept Nephrol, D-3000 Hannover, Germany
[2] Hannover Med Sch, Dept Pathol, D-3000 Hannover, Germany
关键词
biopsy complications; protocol biopsy; renal biopsy; renal transplant biopsy;
D O I
10.1111/j.1600-6143.2005.00988.x
中图分类号
R61 [外科手术学];
学科分类号
摘要
The protocol biopsy strategy has been criticized because of risks and marginal utility. We tested the risk. We performed 1171 protocol biopsies in 508 patients at 6, 12 and 26 weeks after renal transplantation, as well as 499 biopsies as indicated in 429 transplant patients. Biopsies were done as an outpatient procedure using an 18- or 16-gauge automated biopsy needle followed by 4 h bed rest. Complications were: gross hematuria 3.5%, perirenal hematomas 2.5%, arterio-venous fistulas 7.3% and vasovagal reactions 0.5%. Major complications requiring invasive procedures such as blood transfusions or urinary catheter were seen in 1% of cases. The hospitalization rate for observation was 1.9%. According to the Banff criteria of specimen adequacy, biopsies with 18-gauge needles yielded > 7 glomeruli and at least one artery in 53% of cases. Changing the needle size in October 2003, those biopsies done with 16-gauge needles yielded > 7 glomeruli and at least one artery in 76% of cases, while the rate of major complications did not change. In conclusion, transplant protocol biopsies with 16-gauge needles provide better utility and similar risk as biopsies with 18-gauge needles. A 4-h recovery after biopsy appears adequate for discharge.
引用
收藏
页码:1992 / 1996
页数:5
相关论文
共 36 条
[1]  
ALWALL N, 1952, ACTA MED SCAND, V143, P430
[2]  
Bennett A R, 1965, Am J Roentgenol Radium Ther Nucl Med, V95, P372
[3]   THE RESULTS OF 500 PERCUTANEOUS RENAL BIOPSIES [J].
BRUN, C ;
RAASCHOU, F .
ARCHIVES OF INTERNAL MEDICINE, 1958, 102 (05) :716-721
[4]   THE USE OF THE AUTOMATIC CORE BIOPSY SYSTEM IN PERCUTANEOUS RENAL BIOPSIES - A COMPARATIVE-STUDY [J].
BURSTEIN, DM ;
KORBET, SM ;
SCHWARTZ, MM .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1993, 22 (04) :545-552
[5]   Safety and cost effectiveness of pediatric percutaneous renal biopsy [J].
Chesney, DS ;
Brouhard, BH ;
Cunningham, RJ .
PEDIATRIC NEPHROLOGY, 1996, 10 (04) :493-495
[6]   CONVENTIONAL 15G NEEDLE TECHNIQUE FOR RENAL BIOPSY COMPARED WITH ULTRASOUND-GUIDED SPRING-LOADED 18G NEEDLE-BIOPSY [J].
COZENS, NJA ;
MURCHISON, JT ;
ALLAN, PL ;
WINNEY, RJ .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (775) :594-597
[7]   PERCUTANEOUS NATIVE RENAL BIOPSY - COMPARISON OF A 1.2-MM SPRING-DRIVEN SYSTEM WITH A TRADITIONAL 2-MM HAND-DRIVEN SYSTEM [J].
DOYLE, AJ ;
GREGORY, MC ;
TERREROS, DA .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1994, 23 (04) :498-503
[8]   Protocol biopsy of the stable renal transplant:: A multicenter study of methods and complication rates [J].
Furness, PN ;
Philpott, CM ;
Chorbadjian, MT ;
Nicholson, ML ;
Bosmans, JL ;
Corthouts, BL ;
Bogers, JJPM ;
Schwarz, A ;
Gwinner, W ;
Haller, H ;
Mengel, M ;
Seron, D ;
Moreso, F ;
Cañas, C .
TRANSPLANTATION, 2003, 76 (06) :969-973
[9]   ULTRASONIC LOCALIZATION FOR RENAL BIOPSY [J].
GOLDBERG, BB ;
POLLACK, HM ;
KELLERMAN, E .
RADIOLOGY, 1975, 115 (01) :167-170
[10]   Standards for renal biopsies: comparison of inpatient and day care procedures [J].
Hussain, F ;
Watson, AR ;
Hayes, J ;
Evans, J .
PEDIATRIC NEPHROLOGY, 2003, 18 (01) :53-56