Implications of dual-energy-window (DEW) scatter correction inaccuracies for In-111 quantitative geometric mean imaging

被引:4
作者
Choi, CW [1 ]
Barker, WC [1 ]
Buvat, I [1 ]
Carrasquillo, JA [1 ]
Bacharach, SL [1 ]
机构
[1] NIH,WARREN G MAGNUSON CLIN CTR,DEPT NUCL MED,BETHESDA,MD 20892
关键词
D O I
10.1097/00006231-199701000-00016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
There is increasing clinical interest in the use of quantitative imaging for radiopharmaceuticals labelled with In-111. Dual-energy-window (DEW) scatter correction is a frequently used component of planar geometric mean quantitative imaging, but it is known that the scatter multiplier k suffers from significant dependence on the characteristics of the scatter medium. Phantom studies with a variety of source geometries were carried out to determine the clinical impact of this dependence on the quantitative accuracy of tumour imaging carried out in conjunction with attenuation correction. Spheres of various sizes (5-20 ml volumes) containing approximately 3.7 MBq (100 mu Ci) In-111 were imaged at a variety of depths (4.8-10.5 cm) within an elliptical water-filled phantom, as well as in air. Geometric mean emission images were acquired using a 20% photopeak window at 247 keV and a 10% scatter window at 205 keV. These emission images were corrected for attenuation using measured Tc-99(m) transmission data that were scaled to In-111 photon energies. Scatter correction was performed in two ways: (1) using the standard DEW method and (2) using a modified DEW method that takes into account benign scatter in the detector crystal. Errors in the activity estimates ranged from -4% to +3% for method 1 in water, and -5% to +3% for method 2 in water. In air, method 1 ranged from -13% to -5%, and method 2 ranged from -10% to -1%. Method 1 was found to yield an accuracy equivalent to that of method 2, except in conditions of very low patient scatter, when the modified method behaved significantly better. We conclude that in a variety of realistic geometries, variations in scatter fraction as determined by the DEW scatter correction method combined with appropriate attenuation correction need not inhibit accurate absolute quantitation of spherical 'tumours' labelled with In-111 when using planar imaging.
引用
收藏
页码:79 / 86
页数:8
相关论文
共 25 条
[1]  
BUIJS WCAM, 1992, J NUCL MED, V33, P1113
[2]   PRELIMINARY VALIDATION OF THE OPPOSING VIEW METHOD FOR QUANTITATIVE GAMMA-CAMERA IMAGING [J].
EARY, JF ;
APPELBAUM, FL ;
DURACK, L ;
BROWN, P .
MEDICAL PHYSICS, 1989, 16 (03) :382-387
[3]   QUANTITATIVE SPECT IMAGING WITH IN-111 [J].
GILLAND, DR ;
JASZCZAK, RJ ;
TURKINGTON, TG ;
GREER, KL ;
COLEMAN, RE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) :761-766
[4]  
GILLAND DR, 1991, J NUCL MED, V32, P527
[5]  
GILLAND DR, 1994, J NUCL MED, V35, P1707
[6]   THE COMING OF AGE OF CANCER RADIOIMMUNOCONJUGATES [J].
GOLDENBERG, DM ;
SCHLOM, J .
IMMUNOLOGY TODAY, 1993, 14 (01) :5-7
[7]  
GRAHAM LS, 1974, RADIOLOGY, V112, P441
[8]   EXTERNAL IMAGING TECHNIQUES FOR QUANTITATION OF DISTRIBUTION OF I-131 F(AB)2 FRAGMENTS OF MONOCLONAL-ANTIBODY IN HUMANS [J].
HAMMOND, ND ;
MOLDOFSKY, PJ ;
BEARDSLEY, MR ;
MULHERN, CB .
MEDICAL PHYSICS, 1984, 11 (06) :778-783
[9]   SCATTER COMPENSATION TECHNIQUES FOR SPECT [J].
JASZCZAK, RJ ;
FLOYD, CE ;
COLEMAN, RE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (01) :786-793
[10]  
JASZCZAK RJ, 1984, J NUCL MED, V25, P893