Interfragmentary compression forces of scaphoid screws in a sawbone cylinder model

被引:31
作者
Hausmann, J. T. [1 ]
Mayr, W.
Unger, E.
Benesch, T.
Vecsei, V.
Gaebler, C.
机构
[1] Univ Med, Dept Traumatol, Vienna, Austria
[2] Univ Med, Dept Biomed Engn & Phys, Vienna, Austria
[3] Core Unit Med Stat & Informat, Sect Med Stat, Vienna, Austria
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2007年 / 38卷 / 07期
关键词
scaphoid screws; biomechanical testing; Twin Fix; Acutrak; AO screw; HBS screw; fracture compression; sawbone;
D O I
10.1016/j.injury.2006.11.002
中图分类号
R4 [临床医学];
学科分类号
1002 [临床医学]; 100602 [中西医结合临床];
摘要
Various screws have been developed to stabilise fractures of the scaphoid. Commonly used are the Herbert, the HBS, the 3-mm AO and the Acutrak screws. Not long ago a new screw, the Twin Fix, was introduced. This is cannulated and similar in shape and appearance to the classical Herbert screw. In our test series we compared the maximum achievable compression forces of the Twin Fix screw with that of three other screws (AO, HBS and Acutrak screws). To avoid the variations of density, stiffness and rigidity in natural bone, a polyurethane sawbone-based test setup was used. The test series included 10 screws of each type. The compression force was measured using a special strain gauge. The mean compression force was significantly higher for the Twin Fix screw (8 +/- 1 N) and the Acutrak screw (7.6 +/- 0.4/ 0.6 N) in relation to the AID screw (6.8 +/- 1.0/1.4 N) and HBS screw (2 +/- 1 N). We found the Twin Fix and Acutrak screws to be promising in the treatment of scaphoid fractures. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:763 / 768
页数:6
相关论文
共 11 条
[2]
Interfragmentary compression across a simulated scaphoid fracture - Analysis of 3 screws [J].
Beadel, GP ;
Ferreira, L ;
Johnson, JA ;
King, GJW .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2004, 29A (02) :273-278
[3]
EXTERNAL SKELETAL FIXATION OF CANINE TIBIAL OSTEOTOMIES - COMPRESSION COMPARED WITH NO COMPRESSION [J].
HART, MB ;
WU, JJ ;
CHAO, EYS ;
KELLY, PJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (04) :598-605
[4]
Lange R H, 1990, J Orthop Trauma, V4, P275, DOI 10.1097/00005131-199004030-00007
[5]
Arch-shaped versus flat arthrodesis of the ankle joint: strength measurements using synthetic cancellous bone [J].
Lauge-Pedersen, H ;
Aspenberg, P ;
Ryd, L ;
Tanner, KE .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H1) :43-49
[6]
ANIMAL-EXPERIMENTS TO EXAMINE THE HISTOLOGY OF FRACTURE-HEALING IN OSTEOSYNTHESIS WITH EXTERNAL FIXATION AND COMPRESSION [J].
MAYER, G ;
WOLF, E .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1983, 101 (02) :111-120
[7]
Two modifications of the Weil osteotomy: Analysis on sawbone models [J].
Melamed, EA ;
Schon, LC ;
Myerson, MS ;
Parks, BG .
FOOT & ANKLE INTERNATIONAL, 2002, 23 (05) :400-405
[8]
PERREN SM, 1980, CAN J SURG, V23, P228
[9]
ROSEN H, 1979, CLIN ORTHOP RELAT R, P154
[10]
FRACTURE HEALING IN RAT FEMORA AS AFFECTED BY FUNCTIONAL WEIGHT-BEARING [J].
SARMIENTO, A ;
SCHAEFFER, JF ;
BECKERMAN, L ;
LATTA, LL ;
ENIS, JE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (03) :369-375