Measurements of total body water with a foot-to-foot impedancemeter

被引:13
作者
Jaffrin, Michel Y. [1 ]
Moreno, Marie Valerie [1 ]
机构
[1] Univ Technol Compiegne, CNRS, UMR 6600, Dept GB,Biomech & Biomed Engn Lab, F-60205 Compiegne, France
关键词
total body water; bioimpedance spectroscopy; foot-to-foot impedancemetry;
D O I
10.1016/j.medengphy.2007.05.009
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The objective was to set-up a method for measuring total body water volumes (TBW) using a Tefal foot-to-foot impedancemeter (FFI) by comparison with a multifrequency medical impedancemeter and to validate this method against deuterium dilution data. The investigation was carried out in 57 Caucasian adult subjects. Impedancemeters were a Tefal Bodymaster Vision(R) (foot-to-foot) featuring a square wave signal and a Xitron Hydra 4200(R) (5-1000 kHz) using BIS method. TBW was measured by the Xitron using a new method that we have developed which applies the BIS method directly to extra and intracellular fluids combined. Although the high frequency impedance of the FFI (R-hf) was higher than the Xitron infinite frequency resistance and corresponded to a frequency around 100 kHz, TBW differences between the FFI and Xitron were not significant, 0.17 +/- 2.17 L for men (P = 0.694) and 0.04 +/- 1.88 L for women (P = 0.902). Then, our method was tested on another Caucasian population in which Rhf had been measured with the same FFI, together with TBW measurements by deuterium dilution. TBW differences between the FFI and dilution were -0.38 +/- 2.27 L for men (P = 0.237) and -0.72 +/- 2.37 L for women (P = 0.06). Our method permits, at least in a Caucasian healthy population, to measure TBW using this FFI with the same accuracy as a whole body multifrequency medical impedancemeter, and the measurement, made in upright position, is much quicker. (C) 2007 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:483 / 489
页数:7
相关论文
共 15 条
[1]
Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[2]
Boulier A., 2005, International Journal of Body Composition Research, V3, P31
[3]
Predicting body cell mass with bioimpedance by using theoretical methods: A technological review [J].
DeLorenzo, A ;
Andreoli, A ;
Matthie, J ;
Withers, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 82 (05) :1542-1558
[4]
Human hydrometry:: comparison of multifrequency bioelectrical impedance with 2H2O and bromine dilution [J].
Ellis, KJ ;
Wong, WW .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 85 (03) :1056-1062
[5]
Dual-energy x-ray absorptiometry and body composition: Differences between devices and comparison with reference methods [J].
Genton, L ;
Hans, D ;
Kyle, UG ;
Pichard, C .
NUTRITION, 2002, 18 (01) :66-70
[6]
Single- and multifrequency models for bioelectrical impedance analysis of body water compartments [J].
Gudivaka, R ;
Schoeller, DA ;
Kushner, RF ;
Bolt, MJG .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 87 (03) :1087-1096
[7]
Hanai T., 1968, EMULSION SCI
[8]
Total body water measurement by a modification of the bioimpedance spectroscopy method [J].
Jaffrin, Michel Y. ;
Fenech, Marianne ;
Moreno, Marie Valerie ;
Kieffer, Roland .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (10) :873-882
[9]
Evaluation of a foot-to-foot impedance meter measuring extracellular fluid volume in addition to fat-free mass and fat tissue mass [J].
Jaffrin, MY ;
Kieffer, R ;
Moreno, MV .
NUTRITION, 2005, 21 (7-8) :815-824
[10]
Evaluation of two foot-to-foot bioelectrical impedance analysers to assess body composition in overweight and obese adolescents [J].
Lazzer, S ;
Boirie, Y ;
Meyer, M ;
Vermorel, M .
BRITISH JOURNAL OF NUTRITION, 2003, 90 (05) :987-992