Assessment of coronary flow velocity with transthoracic Doppler echocardiography during dobutamine stress echocardiography

被引:56
作者
Takeuchi, M
Miyazaki, C
Yoshitani, H
Otani, S
Sakamoto, K
Yoshikawa, J
机构
[1] Tane Gen Hosp, Dept Internal Med, Nishi Ku, Osaka 5500024, Japan
[2] Osaka City Univ, Grad Sch Med, Dept Internal Med & Cardiol, Osaka 558, Japan
关键词
D O I
10.1016/S0735-1097(01)01322-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The purpose of this study was to evaluate the feasibility of measuring coronary flow velocity (CFV) by transthoracic Doppler echocardiography (TTDE) in the left anterior descending coronary artery (LAD) during contrast-enhanced dobutamine stress echocardiography (DSE). We also assessed the value of TTDE for detecting stress-induced myocardial ischemia in the LAD territory. BACKGROUND Noninvasive assessment of both CFV and wall motion during DSE would enhance the diagnostic accuracy of DSE. METHODS One hundred forty-four consecutive patients underwent CFV recording in the distal LAD by TTDE during contrast-enhanced DSE. Regional wall motion score index (WMSI) in the LAD territory and CFV ratio at peak stress (CFV ratio peak), defined as a ratio of CFV at peak stress to basal CFV, were obtained. RESULTS Coronary flow velocity was successfully recorded in 129 patients (90%) at baseline and during dobutamine infusion. Mean value of CFV ratio peak was 2.39 +/- 0.83 (range: 0.84 to 4.40). There was good correlation between WMSI at peak stress and CFV ratio peak (r = 0.62, p < 0.001). Coronary flow velocity ratio peak was significantly lower in patients who developed stress-induced wall motion abnormality (WMA) in the LAD territory than it was in those patients without WMA (1.51 +/- 0.51 vs. 2.76 +/- 0.65, p < 0.001). A CFV ratio peak <2.1 had a sensitivity of 92% and a specificity of 86% for detecting the presence of stress-induced WMA. CONCLUSIONS Assessment of CFV in the distal LAD during DSE is feasible in the majority of cases and provides a CFV ratio for detecting stress-induced myocardial ischemia in the LAD territory. CT Am Coil Cardiol 2001;38:117-23) (C) 2001 by the American College of Cardiology.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 19 条
[1]   AKINESIS BECOMING DYSKINESIS DURING HIGH-DOSE DOBUTAMINE STRESS ECHOCARDIOGRAPHY - A MARKER OF MYOCARDIAL-ISCHEMIA OR A MECHANICAL PHENOMENON [J].
ARNESE, M ;
FIORETTI, PM ;
COMEL, JH ;
POSTMATJOA, J ;
REIJS, AEM ;
ROELANDT, JRTC .
AMERICAN JOURNAL OF CARDIOLOGY, 1994, 73 (12) :896-899
[2]   Effects of dobutamine on coronary stenosis physiology and morphology - Comparison with intracoronary adenosine [J].
Bartunek, J ;
Wijns, W ;
Heyndrickx, GR ;
de Bruyne, B .
CIRCULATION, 1999, 100 (03) :243-249
[3]   Validation of a new noninvasive, method (contrast-enhanced transthoracic second harmonic echo Doppler) for the evaluation of coronary flow reserve - Comparison with intracoronary Doppler flow wire [J].
Caiati, C ;
Montaldo, C ;
Zedda, N ;
Montisci, R ;
Ruscazio, V ;
Lai, G ;
Cadeddu, J ;
Meloni, L ;
Iliceto, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (04) :1193-1200
[4]   Contrast-enhanced transthoracic second harmonic echo Doppler with adenosine - A noninvasive, rapid and effective method for coronary flow reserve assessment [J].
Caiati, C ;
Zedda, N ;
Montaldo, C ;
Montisci, R ;
Iliceto, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (01) :122-130
[5]   New noninvasive method for coronary flow reserve assessment - Contrast-enhanced transthoracic second harmonic echo Doppler [J].
Caiati, C ;
Montaldo, C ;
Zedda, N ;
Bina, A ;
Iliceto, S .
CIRCULATION, 1999, 99 (06) :771-778
[6]   CORONARY FLOW RESERVE AS A PHYSIOLOGIC MEASURE OF STENOSIS SEVERITY [J].
GOULD, KL ;
KIRKEEIDE, RL ;
BUCHI, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (02) :459-474
[7]   Potential use of transthoracic echocardiography in the assessment of coronary flow reserve [J].
Hildick-Smith, DJR ;
Shapiro, LM .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (07) :590-595
[8]   Noninvasive assessment of significant left anterior descending coronary artery stenosis by coronary flow velocity reserve with transthoracic color Doppler echocardiography [J].
Hozumi, T ;
Yoshida, K ;
Ogata, Y ;
Akasaka, T ;
Asami, Y ;
Takagi, T ;
Morioka, S .
CIRCULATION, 1998, 97 (16) :1557-1562
[9]   Noninvasive assessment of coronary flow velocity and coronary flow velocity reserve in the left anterior descending coronary artery by Doppler echocardiography - Comparison with invasive technique [J].
Hozumi, T ;
Yoshida, K ;
Akasaka, T ;
Asami, Y ;
Ogata, Y ;
Takagi, T ;
Kaji, S ;
Kawamoto, T ;
Ueda, Y ;
Morioka, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (05) :1251-1259
[10]   Coronary physiology revisited - Practical insights from the cardiac catheterization laboratory [J].
Kern, MJ .
CIRCULATION, 2000, 101 (11) :1344-1351