Enumeration of CD34+ cells in cord blood: A variation on a single-platform flow cytometric method based on the ISHAGE gating strategy

被引:62
作者
Brocklebank, AM [1 ]
Sparrow, RL [1 ]
机构
[1] Australian Red Cross Blood Serv Victoria, Dev Unit, Southbank, Vic, Australia
来源
CYTOMETRY | 2001年 / 46卷 / 04期
关键词
CD34; cord blood; ISHAGE; single platform; stem cells;
D O I
10.1002/cyto.1136
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Single-platform flow cytometric absolute cell counting protocols provide increased robustness for CD34+ cell enumeration by limiting potential sources of imprecision. However, samples with any cellular fragmentation or debris, such as card blood samples, provide challenges for these assays. We describe a simple, robust absolute CD34+ cell counting protocol, suitable for cord blood, using TRUCOUNT (TM) absolute count tubes (BD Biosciences, San Jose, CA) and a modified ISHAGE (international Society for Hemototherapy and Graft Engineering) gating strategy. An advantage of TRUCOUNT tubes is that each tube is supplied with a known number of lyophilized fluorescent beads. The method includes no-wash fixative-free ammonium chloride red blood cell lysis and the viability dye, 7-amino actinomycin D, to exclude dead cells. The threshold was set on CD45 expression in the FL1 channel and an exclusion gate in the forward scatter channel reduced debris. No manual adjustment of the gating regions was required, even for samples in less than optimal condition. Comparison of the TRUCOUNT-ISHAGE protocol with the original dual-platform ISHAGE assay (n = 30) and the single-platform ISHAGE protocol using Flow-Count (TM) Fluorospheres (Beckman Coulter, Fullerton, CA; n = 22) showed high correlation (R-2 = 0.949 and 0.989, respectively) and no significant difference or bias for samples ranging from 22 to 600 CD34+ cells per microliter. Results are presented that demonstrate the detrimental effect of a fixative-containing lysis reagent when used in a lyse-and-wash procedure. The TRUCOUNT-ISHAGE protocol combines the attributes of TRUCOUNT tubes and the ISHAGE gating strategy to provide a single-platform protocol capable of achieving readily standardization of CD34+ cell enumeration. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:254 / 261
页数:8
相关论文
共 30 条
[1]  
Barbosa IL, 1999, CYTOMETRY, V38, P274, DOI 10.1002/(SICI)1097-0320(19991215)38:6<274::AID-CYTO3>3.3.CO
[2]  
2-9
[3]   Reduction of intra- and interlaboratory variation in CD34+ stem cell enumeration using stable test material, standard protocols and targeted training [J].
Barnett, D ;
Granger, V ;
Kraan, J ;
Whitby, L ;
Reilly, JT ;
Papa, S ;
Gratama, JW .
BRITISH JOURNAL OF HAEMATOLOGY, 2000, 108 (04) :784-792
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]  
Bossuyt X, 1997, CYTOMETRY, V30, P124
[6]  
Brando B, 2000, CYTOMETRY, V42, P327, DOI 10.1002/1097-0320(20001215)42:6<327::AID-CYTO1000>3.0.CO
[7]  
2-F
[8]   Placental and/or umbilical cord blood: An alternative source of hematopoietic stem cells for transplantation [J].
Cairo, MS ;
Wagner, JE .
BLOOD, 1997, 90 (12) :4665-4678
[9]  
Cassens U, 1998, TRANSFUSION MED, V8, P111
[10]  
Chang A, 1996, J Hematother, V5, P605, DOI 10.1089/scd.1.1996.5.605