Experimental investigation of a micro-combined cooling, heating and power system driven by a gas engine

被引:107
作者
Kong, XQ [1 ]
Wang, RZ [1 ]
Wu, JY [1 ]
Huang, XH [1 ]
Huangfu, Y [1 ]
Wu, DW [1 ]
Xu, YX [1 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200030, Peoples R China
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2005年 / 28卷 / 07期
基金
高等学校博士学科点专项科研基金;
关键词
cogeneration; experiment; generation; gas engine; chiller; adsorption system; water; silica gel; performance; COP;
D O I
10.1016/j.ijrefrig.2005.04.006
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental investigation of the performance of a micro-combined cooling, heating and power (CCHP) system is described. The natural gas and LPG-fired micro-CCHP system uses a small-scale generator set driven by a gas engine and a new small-scale adsorption chiller, which has a rated electricity power of 12 kW, a rated cooling of 9 kW and a rated heating capacity of 28 kW. Silica gel-water is used as working pair in the adsorption cooling system. The refrigeration COP of the adsorption chiller is over 0.3 for 13 degrees C evaporation temperature. The test facility designed and built is described, which supplies better test-rig platform for cooling, heating and power cogeneration. Experimental methodology of this system is presented and the results are discussed. An energetic analysis of micro-CCHP system is performed as well. The overall thermal and electrical efficiency is over 70%. (c) 2005 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:977 / 987
页数:11
相关论文
共 26 条
[1]   Combined power and cooling, an analysis of the combined Diesel-absorption cycle [J].
Agnew, B ;
Talbi, M ;
Mostafavi, M .
APPLIED THERMAL ENGINEERING, 1999, 19 (10) :1097-1105
[2]  
BAKER TD, 1986, ASHRAE T, V92, P318
[3]   Exergetic and engineering analyses of gas turbine based cogeneration systems [J].
Bilgen, E .
ENERGY, 2000, 25 (12) :1215-1229
[4]   A regional energy planning methodology including renewable energy sources and environmental constraints [J].
Cormio, C ;
Dicorato, M ;
Minoia, A ;
Trovato, M .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2003, 7 (02) :99-130
[5]   Effect of reliability considerations on the optimal synthesis, design and operation of a cogeneration system [J].
Frangopoulos, CA ;
Dimopoulos, GG .
ENERGY, 2004, 29 (03) :309-329
[6]   Thermoeconomic evaluation of a gas turbine cogeneration system [J].
Guarinello, F ;
Cerqueira, SAAG ;
Nebra, SA .
ENERGY CONVERSION AND MANAGEMENT, 2000, 41 (11) :1191-1200
[7]   Energetic efficiency of cogeneration systems for combined heat, cold and power production [J].
Havelsky, V .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1999, 22 (06) :479-485
[8]   Experimental investigations on adsorption air-conditioner used in internal-combustion locomotive driver-cabin [J].
Jiangzhou, S ;
Wang, RZ ;
Lu, YZ ;
Xu, YX ;
Wu, JY .
APPLIED THERMAL ENGINEERING, 2002, 22 (10) :1153-1162
[9]   Energy conservation in buildings: cogeneration and cogeneration coupled with thermal-energy storage [J].
Khan, KH ;
Rasul, MG ;
Khan, MMK .
APPLIED ENERGY, 2004, 77 (01) :15-34
[10]   Combined heat and power: Executive summary [J].
Laughton, M .
APPLIED ENERGY, 1996, 53 (1-2) :227-233