Evaluation of a latex agglutination test (MRSA-Screen) for detection of oxacillin resistance in coagulase-negative staphylococci

被引:35
作者
Louie, L
Majury, A
Goodfellow, J
Louie, M
Simor, AE
机构
[1] Sunnybrook & Womens Coll, Hlth Sci Ctr, Dept Microbiol, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Toronto, ON, Canada
关键词
D O I
10.1128/JCM.39.11.4149-4151.2001
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The MRSA-Screen (Denka-Seiken, Tokyo, Japan) latex agglutination test was evaluated for its ability to detect PBP 2a from 200 clinical isolates of coagulase-negative staphylococci (CONS; 84 mecA-positive strains and 116 mecA-negative strains) consisting of 108 Staphylococcus epidermidis, 37 S. saprophyticus, 15 S. haemolyticus, 11 S. hominis, 10 S. capitis, 10 S. warneri, and 3 S. lugdunensis species as well as 6 other species of CONS. The assay was compared with susceptibility testing with an agar screen plate with oxacillin at 6 mug/ml (OXA6), by oxacillin disk diffusion (DD), by broth microdilution (BMDIL), by the E test, and with Vitek GPS-SV and Vitek GPS-107 susceptibility cards. PCR for the detection of the mecA gene was used as the "gold standard." The sensitivities and specificities for the methods evaluated were as follows: MRSA-Screen, 100 and 100%, respectively; OXA6, 100 and 99%, respectively; DD, 98 and 62%, respectively; BMDIL, 100 and 60%, respectively; E test, 100 and 51%, respectively; Vitek GPS-SV susceptibility card, 98 and 87%, respectively; and Vitek GPS-107 susceptibility card, 100 and 61%, respectively. The MRSA-Screen test accurately and rapidly detected oxacillin resistance in CONS.
引用
收藏
页码:4149 / 4151
页数:3
相关论文
共 20 条
[1]  
[Anonymous], 1999, M100S9 NAT COMM CLIN
[2]   DETECTION OF STAPHYLOCOCCUS-AUREUS BY POLYMERASE CHAIN-REACTION AMPLIFICATION OF THE NUC GENE [J].
BRAKSTAD, OG ;
AASBAKK, K ;
MAELAND, JA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (07) :1654-1660
[3]   Nosocomial bloodstream infections in United States hospitals: A three-year analysis [J].
Edmond, MB ;
Wallace, SE ;
McClish, DK ;
Pfaller, MA ;
Jones, RN ;
Wenzel, RP .
CLINICAL INFECTIOUS DISEASES, 1999, 29 (02) :239-244
[4]   EFFECT OF SOURCE OF MUELLER-HINTON AGAR ON DETECTION OF OXACILLIN RESISTANCE IN STAPHYLOCOCCUS-AUREUS USING A SCREENING METHODOLOGY [J].
HINDLER, JA ;
WARNER, NL .
JOURNAL OF CLINICAL MICROBIOLOGY, 1987, 25 (04) :734-735
[5]   Correlation of oxacillin MIC with mecA gene carriage in coagulase-negative staphylococci [J].
Hussain, Z ;
Stoakes, L ;
Massey, V ;
Diagre, D ;
Fitzgerald, V ;
El Sayed, S ;
Lannigan, R .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (02) :752-754
[6]  
Hussain Z, 2000, J CLIN MICROBIOL, V38, P2051
[7]   UPDATE ON CLINICAL-SIGNIFICANCE OF COAGULASE-NEGATIVE STAPHYLOCOCCI [J].
KLOOS, WE ;
BANNERMAN, TL .
CLINICAL MICROBIOLOGY REVIEWS, 1994, 7 (01) :117-140
[8]   Comparison of susceptibility testing methods with mecA gene analysis for determining oxacillin (methicillin) resistance in clinical isolates of Staphylococcus aureus and coagulase-negative Staphylococcus spp. [J].
Kohner, P ;
Uhl, J ;
Kolbert, C ;
Persing, D ;
Cockerill, F .
JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (09) :2952-2961
[9]  
Louie L, 2000, J CLIN MICROBIOL, V38, P2170
[10]  
Marriott DJE, 1999, J CLIN MICROBIOL, V37, P3783