Hypertonic saline method accurately determines parallel conductance for dual-field conductance catheter

被引:104
作者
Steendijk, P [1 ]
Staal, E [1 ]
Jukema, JW [1 ]
Baan, J [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Cardiol, NL-2300 RC Leiden, Netherlands
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2001年 / 281卷 / 02期
关键词
angiography; left ventricular volume; sheep; ventricular function;
D O I
10.1152/ajpheart.2001.281.2.H755
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Conversion of conductance catheter data to absolute ventricular volumes requires assessment of parallel conductance (G(P)). We determined the accuracy of G(P) obtained by the hypertonic saline method (G(saline)(P)) compared with angiographically derived G(P) (G(Angio)(P)) and quantified the variabilities of G(P) for the dual-field conductance catheter method in nine anesthetized sheep studied at baseline, treated with dobutamine, and subjected to volume loading and beta -blockade. G(saline)(P) and G(Angio)(P) showed an excellent linear correlation (G(saline)(P) = 1.002.G(Angio)(P) + 0.001 Omega (-1), R-2 = 0.92), and Bland-Altman analysis yielded a nonsignificant bias and narrow limits of agreement (bias +/- 2SD = 0.002 +/- 0.112 Omega (-1)). Within-animal variability of G(P) was very similar with both methods and was due to changes in blood conductivity rather than geometrical changes. Variability between animals was significant (26.3% of mean for G(saline)(P) and 25.7% for G(Angio)(P)) and thus warrants individual assessment. Variations during the cardiac cycle were not significantly different from zero. With biplane angiography used as gold standard, the hypertonic saline method accurately determines G(P) for the dual-field conductance catheter over a wide range of hemodynamic conditions.
引用
收藏
页码:H755 / H763
页数:9
相关论文
共 36 条
  • [1] Validation of right and left ventricular conductance and echocardiography for cardiac function studies
    Amirhamzeh, MMR
    Dean, DA
    Jia, CX
    Cabreriza, SE
    Yano, OJ
    Burkhoff, D
    Spotnitz, HM
    [J]. ANNALS OF THORACIC SURGERY, 1996, 62 (04) : 1104 - 1109
  • [2] SIMULTANEOUS CONDUCTANCE CATHETER AND DIMENSION ASSESSMENT OF LEFT-VENTRICLE VOLUME IN THE INTACT ANIMAL
    APPLEGATE, RJ
    CHENG, CP
    LITTLE, WC
    [J]. CIRCULATION, 1990, 81 (02) : 638 - 648
  • [3] CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER
    BAAN, J
    VANDERVELDE, ET
    DEBRUIN, HG
    SMEENK, GJ
    KOOPS, J
    VANDIJK, AD
    TEMMERMAN, D
    SENDEN, J
    BUIS, B
    [J]. CIRCULATION, 1984, 70 (05) : 812 - 823
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] LEFT-VENTRICULAR VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN INTACT DOGS - PARALLEL CONDUCTANCE VOLUME DEPENDS ON LEFT-VENTRICULAR SIZE
    BOLTWOOD, CM
    APPLEYARD, RF
    GLANTZ, SA
    [J]. CIRCULATION, 1989, 80 (05) : 1360 - 1377
  • [6] ACCURACY OF VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN ISOLATED, EJECTING CANINE HEARTS
    BURKHOFF, D
    VANDERVELDE, E
    KASS, D
    BAAN, J
    MAUGHAN, WL
    SAGAWA, K
    [J]. CIRCULATION, 1985, 72 (02) : 440 - 447
  • [7] THE CONDUCTANCE VOLUME CATHETER TECHNIQUE FOR MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN YOUNG PIGLETS
    CASSIDY, SC
    TEITEL, DF
    [J]. PEDIATRIC RESEARCH, 1992, 31 (01) : 85 - 90
  • [8] CONTINUOUS BLOOD DENSITY-MEASUREMENTS AND VOLUME CHANGES DURING EXTRACORPOREAL-CIRCULATION IN PATIENTS UNDERGOING CARDIAC-SURGERY
    DACAR, D
    [J]. THORACIC AND CARDIOVASCULAR SURGEON, 1995, 43 (01) : 13 - 18
  • [9] THE USE OF BIPLANE ANGIOCARDIOGRAPHY FOR THE MEASUREMENT OF LEFT VENTRICULAR VOLUME IN MAN
    DODGE, HT
    SANDLER, H
    BALLEW, DW
    LORD, JD
    [J]. AMERICAN HEART JOURNAL, 1960, 60 (05) : 762 - 776
  • [10] Feldman Marc D., 1993, Journal of the American College of Cardiology, V21, p372A