Comparison of in vivo eccentricity and symmetry indices between metallic stents and bioresorbable vascular scaffolds: Insights from the ABSORB and SPIRIT trials

被引:49
作者
Brugaletta, Salvatore [1 ,2 ]
Gomez-Lara, Josep [1 ]
Diletti, Roberto [1 ]
Farooq, Vasim [1 ]
van Geuns, Robert Jan [1 ]
de Bruyne, Bernard
Dudek, Dariusz [3 ]
Garcia-Garcia, Hector M. [1 ,4 ]
Ormiston, John A. [5 ]
Serruys, Patrick W. [1 ]
机构
[1] Erasmus MC, Thoraxctr, NL-3015 CE Rotterdam, Netherlands
[2] Univ Barcelona, Hosp Clin, Thorax Inst, Barcelona, Spain
[3] Jagiellonian Univ, Krakow, Poland
[4] Cardialysis BV, Rotterdam, Netherlands
[5] Auckland City Hosp, Auckland, New Zealand
关键词
BVS; eccentricity; symmetry; IVUS; XIENCE V; ELUTING CORONARY STENT; INTRAVASCULAR ULTRASOUND ANALYSIS; BENESTENT-II PILOT; ARTERY-DISEASE; IMPLANTATION; ANGIOGRAPHY; PREDICTORS; CONFORMABILITY; DETERMINANTS; RESTENOSIS;
D O I
10.1002/ccd.22996
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Objective: To compare the geometrical parameters of a bioresorbable vascular scaffold (BVS) with a standard metallic stent. Background: The introduction of polymeric bioresorbable materials in the design of novel coronary scaffolds may affect some geometrical parameters, such as eccentricity and symmetry indices, previously introduced as IVUS criteria for optimal metallic stent deployment. Methods: From ABSORB Cohort A, ABSORB Cohort B, SPIRIT I, and SPIRIT II, all patients implanted with BVS 1.0, BVS 1.1, or XIENCE V, respectively and intravascular ultrasound analyses post-implantation were selected. The eccentricity index was calculated frame by frame and expressed as an average per device (minimum diameter/maximum diameter). The symmetry index of the device was reported as ([maximum diameter - minimum diameter]/maximum diameter).Six months major adverse cardiac events (MACE) were analyzed. Results: A total of 242 patients were selected (BVS 1.0: n = 28, BVS 1.1: n = 94, XIENCE V: n = 120). The BVS exhibited a significantly lower eccentricity index (BVS 1.0: 0.83 +/- 0.09; BVS 1.1: 0.85 +/- 0.08; XIENCE V: 0.90 +/- 0.06; P < 0.01) and a significantly higher symmetry index (BVS 1.0: 0.30 +/- 0.07; BVS 1.1: 0.31 +/- 0.06, XIENCE V 0.26 +/- 0.07; P < 0.01) as compared to the XIENCE V. An inverse correlation was found between the symmetry and eccentricity indices for both (BVS r = -0.69, P < 0.01; XIENCE V r = -0.61, P < 0.01). No differences in MACE were detected between the groups according to their geometrical parameters. Conclusions: The introduction of a new polymeric material in the design of BVS resulted in a lower eccentricity index and a higher symmetry index as compared to metallic stents, without detectable impact in MACE, at 6 months. (C) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:219 / 228
页数:10
相关论文
共 33 条
[1]
Findings of intravascular ultrasound during acute stent thrombosis [J].
Alfonso, F ;
Suárez, A ;
Angiolillo, DJ ;
Sabaté, M ;
Escaned, J ;
Moreno, R ;
Hernández, R ;
Bañuelos, C ;
Macaya, C .
HEART, 2004, 90 (12) :1455-1459
[2]
Intravascular ultrasound findings during episodes of drug-eluting Stent thrombosis [J].
Alfonso, Fernando ;
Suarez, Alfonso ;
Perez-Vizcayno, Maria J. ;
Moreno, Raul ;
Escaned, Javier ;
Banuelos, Camino ;
Jimenez, Pilar ;
Bernardo, Esther ;
Angiolillo, Dominick J. ;
Hernandez, Rosana ;
Macaya, Carlos .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (21) :2095-2097
[3]
Brugaletta S, 2010, INT J IN PRESS 1013
[4]
Predictors of subacute stent thrombosis - Results of a systematic intravascular ultrasound study [J].
Cheneau, E ;
Leborgne, L ;
Mintz, GS ;
Kotani, J ;
Pichard, AD ;
Satler, LF ;
Canos, D ;
Castagna, M ;
Weissman, NJ ;
Waksman, R .
CIRCULATION, 2003, 108 (01) :43-47
[5]
Three-dimensional intravascular ultrasonic volumetric quantification of stent recoil and neointimal formation of two new generation tubular stents [J].
Costa, MA ;
Sabate, M ;
Kay, IP ;
de Feyter, PJ ;
Kozuma, K ;
Serrano, P ;
de Valk, V ;
Albertal, M ;
Ligthart, JMR ;
Disco, C ;
Foley, DP ;
Serruys, PW .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (02) :135-139
[6]
Reference chart derived from post-stent-implantation intravascular ultrasound predictors of 6-month expected restenosis on quantitative coronary angiography [J].
de Feyter, PJ ;
Kay, P ;
Disco, C ;
Serruys, PW .
CIRCULATION, 1999, 100 (17) :1777-1783
[7]
Intravascular ultrasound-guided optimized stent deployment - Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study) [J].
de Jaegere, P ;
Mudra, H ;
Figulla, H ;
Almagor, Y ;
Doucet, S ;
Penn, I ;
Colombo, A ;
Hamm, C ;
Bartorelli, A ;
Rothman, M ;
Nobuyoshi, M ;
Yamaguchi, T ;
Voudris, V ;
DiMario, C ;
Makovski, S ;
Hausmann, D ;
Rowe, S ;
Rabinovich, S ;
Sunamura, M ;
van Es, GA .
EUROPEAN HEART JOURNAL, 1998, 19 (08) :1214-1223
[8]
Impact of Post-Intervention Minimal Stent Area on 9-Month Follow-Up Patency of Paclitaxel-Eluting Stents An Integrated Intravascular Ultrasound Analysis From the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials [J].
Doi, Hiroshi ;
Maehara, Akiko ;
Mintz, Gary S. ;
Yu, Alan ;
Wang, Hong ;
Mandinov, Lazar ;
Popma, Jeffrey J. ;
Ellis, Stephen G. ;
Grube, Eberhard ;
Dawkins, Keith D. ;
Weissman, Neil J. ;
Turco, Mark A. ;
Ormiston, John A. ;
Stone, Gregg W. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (12) :1269-1275
[9]
BENEFIT OF INTRACORONARY ULTRASOUND IN THE DEPLOYMENT OF PALMAZ-SCHATZ STENTS [J].
GOLDBERG, SL ;
COLOMBO, A ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
TOBIS, JM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (04) :996-1003
[10]
A Comparison of the Conformability of Everolimus-Eluting Bioresorbable Vascular Scaffolds to Metal Platform Coronary Stents [J].
Gomez-Lara, Josep ;
Garcia-Garcia, Hector M. ;
Onuma, Yoshinobu ;
Garg, Scot ;
Regar, Evelyn ;
De Bruyne, Bernard ;
Windecker, Stefan ;
McClean, Dougal ;
Thuesen, Leif ;
Dudek, Dariusz ;
Koolen, Jacques ;
Whitbourn, Robert ;
Smits, Pieter C. ;
Chevalier, Bernard ;
Dorange, Cecile ;
Veldhof, Susan ;
Morel, Marie-Angele ;
de Vries, Ton ;
Ormiston, John A. ;
Serruys, Patrick W. .