A Comparison of the Conformability of Everolimus-Eluting Bioresorbable Vascular Scaffolds to Metal Platform Coronary Stents

被引:85
作者
Gomez-Lara, Josep [1 ]
Garcia-Garcia, Hector M. [1 ,2 ]
Onuma, Yoshinobu [1 ]
Garg, Scot [1 ]
Regar, Evelyn [1 ]
De Bruyne, Bernard [3 ]
Windecker, Stefan [4 ]
McClean, Dougal [5 ]
Thuesen, Leif [6 ]
Dudek, Dariusz [7 ]
Koolen, Jacques [8 ]
Whitbourn, Robert [9 ]
Smits, Pieter C. [10 ]
Chevalier, Bernard [11 ]
Dorange, Cecile [12 ]
Veldhof, Susan [12 ]
Morel, Marie-Angele [2 ]
de Vries, Ton [2 ]
Ormiston, John A. [13 ]
Serruys, Patrick W. [1 ]
机构
[1] Erasmus MC, Thoraxctr, Rotterdam, Netherlands
[2] Cardialysis, Rotterdam, Netherlands
[3] Ctr Cardiovasc, Aalst, Belgium
[4] Swiss Cardiovasc Ctr, Bern, Switzerland
[5] Christchurch Hosp, Christchurch, New Zealand
[6] Aarhus Univ Hosp, Skejby Sygehus, Skejby, Denmark
[7] Jagiellonian Univ, Krakow, Poland
[8] Catharina Hosp, Eindhoven, Netherlands
[9] St Vincents Hosp, Fitzroy, Vic 3065, Australia
[10] Maasstad Ziekenhuis, Rotterdam, Netherlands
[11] Inst Cardiovasc Paris Sud, Massy, France
[12] Abbott Vasc, Diegem, Belgium
[13] Auckland City Hosp, Auckland, New Zealand
关键词
angulation; bioresorbable; curvature; conformability; stent; SHEAR-STRESS; IMPLANTATION; FRACTURE; ARTERY; RESTENOSIS; ABSORB; FLEXIBILITY; PREDICTORS; THICKNESS; LESIONS;
D O I
10.1016/j.jcin.2010.07.016
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Objectives The aim of this study was to assess the differences in terms of curvature and angulation of the treated vessel after the deployment of either a metallic stent or a polymeric scaffold device. Background Conformability of metallic platform stents (MPS) is the major determinant of geometric changes in coronary arteries caused by the stent deployment. It is not known how bioresorbable polymeric devices perform in this setting. Methods This retrospective study compares 102 patients who received an MPS (Multi-link Vision or Xience V, Abbott Vascular, Santa Clara, California) in the SPIRIT FIRST and II trials with 89 patients treated with the Revision 1.1 everolimus-eluting bioresorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, California) from cohort B of the ABSORB (A bioabsorbable everolimus-eluting coronary stent system) trial. All patients were treated with a single 3 x 18 mm device. Curvature and angulation were measured with dedicated software by angiography. Results Both the MPS and BVS groups had significant changes in relative region curvature (MPS vs. BVS: 28.7% vs. 7.5%) and angulation (MPS vs. BVS: 25.4% vs. 13.4%) after deployment. The unadjusted comparisons between the 2 groups showed for BVS a nonsignificant trend for less change in region curvature after deployment (MPS vs. BVS: 0.085 cm(-1) vs. 0.056 cm(-1), p = 0.06) and a significantly lower modification of angulation (MPS vs. BVS 6.4 degrees vs. 4.3 degrees, p = 0.03). By multivariate regression analysis, the independent predictors of changes in curvature and angulation were the pretreatment region curvature, the pre-treatment region angulation, and the used device. Conclusions Bioresorbable vascular scaffolds have better conformability than conventional MPS. The clinical significance of the observed differences will require further investigation. (J Am Coll Cardiol Intv 2010;3:1190-8) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:1190 / 1198
页数:9
相关论文
共 32 条
[1]
FLOW PATTERNS AND SPATIAL-DISTRIBUTION OF ATHEROSCLEROTIC LESIONS IN HUMAN CORONARY-ARTERIES [J].
ASAKURA, T ;
KARINO, T .
CIRCULATION RESEARCH, 1990, 66 (04) :1045-1066
[2]
Bruining Nico, 2008, EuroIntervention, V4, P285, DOI 10.4244/EIJV4I2A49
[3]
Methods for Quantifying Three-Dimensional Deformation of Arteries due to Pulsatile and Nonpulsatile Forces: Implications for the Design of Stents and Stent Grafts [J].
Choi, Gilwoo ;
Cheng, Christopher P. ;
Wilson, Nathan M. ;
Taylor, Charles A. .
ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (01) :14-33
[4]
Selection of coronary stents [J].
Colombo, A ;
Stankovic, G ;
Moses, JW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (06) :1021-1033
[5]
RESULTS OF PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY OF HIGH-RISK ANGULATED STENOSES [J].
ELLIS, SG ;
TOPOL, EJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (12) :932-937
[6]
Usefulness of shear stress pattern in predicting neointima distribution in sirolimus-eluting stents in coronary arteries [J].
Gijsen, FJH ;
Oortman, RM ;
Wentzel, JJ ;
Schuurbiers, JCH ;
Tanabe, K ;
Degertekin, M ;
Ligthart, JM ;
Thury, A ;
de Feyter, PJ ;
Serruys, PW ;
Slager, CJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (11) :1325-1328
[7]
Longitudinal straightening effect of stents is an additional predictor for major adverse cardiac events [J].
Gyöngyösi, M ;
Yang, P ;
Khorsand, A ;
Glogar, D .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (06) :1580-1589
[8]
Predictors and Prognosis of Stent Fracture After Sirolimus-Eluting Stent Implantation [J].
Ino, Yasushi ;
Toyoda, Yasuaki ;
Tanaka, Atsushi ;
Ishii, Shuuta ;
Kusuyama, Yoshio ;
Kubo, Takashi ;
Takarada, Shigeho ;
Kitabata, Hironori ;
Tanimoto, Takashi ;
Mizukoshi, Masato ;
Imanishi, Toshio ;
Akasaka, Takashi .
CIRCULATION JOURNAL, 2009, 73 (11) :2036-2041
[9]
Frequency of Stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation [J].
Lee, Sang-Hee ;
Park, Jong-Seon ;
Shin, Dong-Gu ;
Kim, Young-Jo ;
Hong, Gue-Ru ;
Kim, Woong ;
Shim, Bong-Sup .
AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (04) :627-630
[10]
Three-dimensional analysis of in vivo coronary stent - coronary artery interactions [J].
Liao, R ;
Green, NE ;
Chen, SYJ ;
Messenger, JC ;
Hansgen, AR ;
Groves, BM ;
Carroll, JD .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2004, 20 (04) :305-313