Biornechanical analysis of a newly designed bioabsorbable anterior cervical plate

被引:8
作者
Ames, CP
Acosta, FL
Chamberlain, RH
Larios, AE
Crawford, NR
机构
[1] Univ Calif San Francisco, Dept Neurol Surg, San Francisco, CA 94143 USA
[2] Barrow Neurol Inst, Spinal Biomech Res Lab, Phoenix, AZ 85013 USA
关键词
anterior cervical plate fixation; anterior cervical discectorny and fusion; bioabsorbable plate; cadaver dissection;
D O I
10.3171/spi.2005.3.6.0465
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. The authors present a biomechanical analysis of a newly designed bioabsorbable anterior cervical plate (ACP) for the treatment of one-level cervical degenerative disc disease. They Studied anterior cervical discectomy and fusion (ACDF) in a human cadaveric model, comparing the stability of the cervical spine after placement of the bioabsorbable fusion plate, a bioabsorbable mesh. and a more traditional metallic ACP. Methods. Seven human cadaveric specimens underwent a C6-7 fibular graft-assisted ACDF placement. A one-level resorbable ACP was then placed and secured with bioabsorbable screws. Flexibility testing was performed on both intact and instrumented specimens using a servohydraulic system to create flexion-extension, lateral bending, and axial rotation motions. After data analysis, three parameters were calculated: angular range of motion, lax zone, and stiff zone. The results were compared with those obtained in a previous study of a resorbable fusion mesh and with those acquired using metallic fusion ACPs. For all parameters Studied, the resorbable plate consistently conferred greater stability than the resorbable mesh. Moreover, it offered comparable stability with that of metallic fusion ACPs. Conclusions. Bioabsorbable plates provide better stability than resorbable mesh. Although the results of this study do not necessarily indicate that a resorbable plate confers equivalent stability to a metal plate, the resorbable ACP certainly yielded better results than the resorbable mesh. Bioabsorbable fusion ACPs should therefore be considered as alternatives to metal plates when a graft containment device is required.
引用
收藏
页码:465 / 470
页数:6
相关论文
共 20 条
[1]
Biomechanical analysis of a resorbable anterior cervical graft containment plate [J].
Ames, CP ;
Crawford, NR ;
Chamberlain, RH ;
Deshmukh, V ;
Sadikovic, B ;
Sonntag, VKH .
SPINE, 2005, 30 (09) :1031-1038
[2]
Ames CP, 2002, ORTHOPEDICS, V25, pS1149
[3]
Feasibility of a resorbable anterior cervical graft containment plate [J].
Ames, CP ;
Cornwall, GB ;
Crawford, NR ;
Nottmeier, E ;
Chamberlain, RH ;
Sonntag, VKH .
JOURNAL OF NEUROSURGERY, 2002, 97 (04) :440-446
[4]
Branch C L Jr, 1999, Clin Neurosurg, V45, P22
[5]
Outcome analysis of noninstrumented anterior cervical discectomy and interbody fusion in 348 patients [J].
Cauthen, JC ;
Kinard, RE ;
Vogler, JB ;
Jackson, DE ;
DePaz, OB ;
Hunter, OL ;
Wasserburger, LB ;
Williams, VM .
SPINE, 1998, 23 (02) :188-192
[6]
Internal Le Fort III distraction with biodegradable devices [J].
Cohen, SR ;
Holmes, RE .
JOURNAL OF CRANIOFACIAL SURGERY, 2001, 12 (03) :264-272
[7]
A new technique for determining 3-D joint angles: the tilt/twist method [J].
Crawford, NR ;
Yamaguchi, GT ;
Dickman, CA .
CLINICAL BIOMECHANICS, 1999, 14 (03) :153-165
[8]
AN APPARATUS FOR APPLYING PURE NONCONSTRAINING MOMENTS TO SPINE SEGMENTS IN-VITRO [J].
CRAWFORD, NR ;
BRANTLEY, AGU ;
DICKMAN, CA ;
KOENEMAN, EJ .
SPINE, 1995, 20 (19) :2097-2100
[9]
Construction of local vertebral coordinate systems using a digitizing probe - Technical note [J].
Crawford, NR ;
Dickman, CA .
SPINE, 1997, 22 (05) :559-563
[10]
Crawford NR, 1998, J SPINAL DISORD, V11, P416