Management of iatrogenic spinal stenosis complicating placement of a fusion cage - A case report

被引:21
作者
Glassman, SD
Johnson, JR
Raque, G
Puno, RM
Dimar, JR
机构
[1] UNIV LOUISVILLE,DEPT ORTHOPAED SURG,LOUISVILLE,KY 40292
[2] UNIV LOUISVILLE,DEPT NEUROSURG,LOUISVILLE,KY 40292
[3] KENTON D LEATHERMAN SPINE CTR,LOUISVILLE,KY
关键词
complication; fusion cage; posterior lumbar interbody fusion; retropulsion;
D O I
10.1097/00007632-199610150-00018
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A case of iatrogenic spinal stenosis secondary to fusion cage retropulsion is presented. Objectives. To highlight fusion cage retropulsion, a potential complication that may become more prevalent as the use of fusion cage instrumentation expands. The difficulty in management of this complication is emphasized. Summary of Background Data. Early reports regarding fusion cage instrumentation have been encouraging. At this point, however, the potential benefits are better defined than the potential complications. Methods. A significant complication of fusion cage instrumentation and the limited literature on this subject are reviewed. Results. The patient underwent successful revision surgery after retropulsion of a fusion cage, however, an extensive surgical procedure including partial vertebral body resection was required. Conclusions. The frequency and severity of complications related to fusion cage instrumentation main poorly defined. Caution should be used, in patient selection until additional experience more clearly defines the risk-to-benefit ratio for a given application of this new technology.
引用
收藏
页码:2383 / 2386
页数:4
相关论文
共 16 条
[1]
A CARBON-FIBER IMPLANT TO AID INTERBODY LUMBAR FUSION - 2-YEAR CLINICAL-RESULTS IN THE 1ST 26 PATIENTS [J].
BRANTIGAN, JW ;
STEFFEE, AD .
SPINE, 1993, 18 (14) :2106-2117
[2]
BRANTIGAN JW, 1994, SPINE, V10, P1436
[3]
GLASSMAN SD, 1995, SPINE, V20, P1375, DOI 10.1097/00007632-199506000-00008
[4]
Goldner J L, 1971, Orthop Clin North Am, V2, P543
[5]
Holte D C, 1994, Eur Spine J, V3, P32, DOI 10.1007/BF02428314
[6]
INOUE SI, 1984, CLIN ORTHOPAEDICS, V183, P22
[7]
INTERSPACE DISTRACTION AND GRAFT SUBSIDENCE AFTER ANTERIOR LUMBAR FUSION WITH FEMORAL STRUT ALLOGRAFT [J].
KUMAR, A ;
KOZAK, JA ;
DOHERTY, BJ ;
DICKSON, JH .
SPINE, 1993, 18 (16) :2393-2400
[8]
KUSLICH SD, 1994, 6 ANN N AM SPIN SOC
[9]
CHRONIC DISABLING LOW-BACK-PAIN SYNDROME CAUSED BY INTERNAL DISC DERANGEMENTS - THE RESULTS OF DISC EXCISION AND POSTERIOR LUMBAR INTERBODY FUSION [J].
LEE, CK ;
VESSA, P ;
LEE, JK .
SPINE, 1995, 20 (03) :356-361
[10]
LORENZ M, 1991, SPINE S8, V16, P455