Improvement of detection specificity of Plasmodium-infected murine erythrocytes by flow cytometry using autofluorescence and YOYO-1

被引:39
作者
Jiménez-Díaz, MB [1 ]
Rullas, J [1 ]
Mulet, T [1 ]
Fernández, L [1 ]
Bravo, C [1 ]
Gargallo-Viola, D [1 ]
Angulo-Barturen, I [1 ]
机构
[1] GlaxoSmithKline Inc, Dis Dev World, Drug Discovery Biol, Madrid 28760, Spain
关键词
malaria; flow cytometry; YOYO-1; autofluorescence; murine models;
D O I
10.1002/cyto.a.20169
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Microscopic analysis of blood smears is currently the most frequently used method to measure parasitemias in experiments of drug efficacy in murine models of malaria. However, it is subjective and labour intensive, which preclude its utilization in large-scale evaluation programs. Flow cytometry is an alternative method, but due to the limited specificity achieved with the currently available techniques, it has not been widely used in murine models of malaria during preclinical evaluation. We describe a new flow cytometric method based on the differences of autofluorescence and DNA content measured after staining with YOYO-1 that are observed in infected erythrocytes compared with noninfected erythrocytes. Methods: Samples of blood from Plasmodium yoelii-infected animals were fixed with glutaraldehyde, incubated with RNAase, and stained with YOYO-1 in 96-well plate format. After acquisition, erythrocytes gated in logarithmic side/scatter plots were analyzed in bidimensional FL-2/YOYO-1 plots in comparison with unidimensional YOYO-1 analysis. Results: The infected erythrocytes showed a characteristic pattern of staining different from that of noninfected erythrocytes. In routine evaluation, the limit of sensitivity was 0.01% and the measurements of parasitemia were linear at parasitemias above 0.1%. Interestingly, using this approach, infected reticulocytes could be differentiated from infected normocytes. Conclusions: The method described is robust, increases the specificity and sensitivity of detection in routine testing, and is especially well suited for detection of low parasitemias in murine models of malaria. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:27 / 36
页数:10
相关论文
共 37 条
[11]   TOTO AND YOYO - NEW VERY BRIGHT FLUOROCHROMES FOR DNA CONTENT ANALYSES BY FLOW-CYTOMETRY [J].
HIRONS, GT ;
FAWCETT, JJ ;
CRISSMAN, HA .
CYTOMETRY, 1994, 15 (02) :129-140
[12]   CELL-CYCLE ANALYSIS OF ASEXUAL STAGES OF ERYTHROCYTIC MALARIA PARASITES [J].
JACOBBERGER, JW ;
HORAN, PK ;
HARE, JD .
CELL PROLIFERATION, 1992, 25 (05) :431-445
[13]   ANALYSIS OF MALARIA PARASITE-INFECTED BLOOD BY FLOW-CYTOMETRY [J].
JACOBBERGER, JW ;
HORAN, PK ;
HARE, JD .
CYTOMETRY, 1983, 4 (03) :228-237
[14]  
JANSE CJ, 1994, METHOD CELL BIOL, V42, P295
[15]   PLASMODIUM SPECIES - FLOW-CYTOMETRY AND MICROFLUOROMETRY ASSESSMENTS OF DNA CONTENT AND SYNTHESIS [J].
JANSE, CJ ;
VANVIANEN, PH ;
TANKE, HJ ;
MONS, B ;
PONNUDURAI, T ;
OVERDULVE, JP .
EXPERIMENTAL PARASITOLOGY, 1987, 64 (01) :88-94
[16]   Evaluation of flow cytometric enumeration of foetal erythrocytes in maternal blood [J].
Janssen, WCM ;
Hoffmann, JJML .
CLINICAL AND LABORATORY HAEMATOLOGY, 2002, 24 (02) :89-92
[17]   Double staining of Plasmodium falciparum nucleic acids with hydroethidine and thiazole orange for cell cycle stage analysis by flow cytometry [J].
Jouin, H ;
Daher, W ;
Khalife, J ;
Ricard, I ;
Puijalon, OM ;
Capron, M ;
Dive, D .
CYTOMETRY PART A, 2004, 57A (01) :34-38
[18]  
Kadjoian V, 1992, J Pharm Belg, V47, P499
[19]  
Landau Irene, 1998, P401
[20]   CHARACTERIZATION OF THE BINDING OF YO TO [POLY(DA-DT)](2) AND [POLY(DG-DC)](2), AND OF THE FLUORESCENT PROPERTIES OF YO AND YOYO COMPLEXED WITH THE POLYNUCLEOTIDES AND DOUBLE-STRANDED DNA [J].
LARSSON, A ;
CARLSSON, C ;
JONSSON, M .
BIOPOLYMERS, 1995, 36 (02) :153-167