Quantifying spatial localization of optical mapping using Monte Carlo simulations

被引:57
作者
Ding, L
Splinter, R
Knisley, SB
机构
[1] Univ N Carolina, Dept Biomed Engn, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Dept Med, Chapel Hill, NC 27599 USA
[3] Georgia Inst Technol, Dept Elect Engn, Atlanta, GA 30332 USA
[4] Carolinas Med Ctr, Laser & Appl Technol Lab, Charlotte, NC 28203 USA
[5] Univ N Carolina, Dept Phys, Charlotte, NC 28223 USA
关键词
cardiac tissue; integrating spheres; Kubelka-Munk; Monte Carlo; optical mapping; spatial localization;
D O I
10.1109/10.951512
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Optical mapping techniques used to study spatial distributions of cardiac activity can be divided into two categories. 1) Broad-field excitation method, in which hearts stained with voltage or calcium sensitive dyes are illuminated with broad-field excitation light and fluorescence is collected by image or photodiode arrays. 2) Laser scanning method, in which illumination uses a scanning laser and fluorescence is collected with a photomultiplier tube. The spatial localization of the fluorescence signal for these two methods is unknown and may depend upon light absorption and scattering at both excitation and emission wavelengths. We measured the absorption coefficients (mu (a)), scattering coefficients (mu (s)), and scattering anisotropy coefficients (g) at representative excitation and emission wavelengths in rabbit heart tissue stained with di-4-ANEPPS or co-stained with both Rh237 and Oregon Green 488 BAPTA 1. Monte Carlo models were then used to simulate absorption and scattering of excitation light and fluorescence emission light for both broad-field and laser methods in three-dimensional tissue. Contributions of local emissions throughout the tissue to fluorescence collected from the tissue surface were determined for both methods. Our results show that spatial localization depends on the light absorption and scattering in tissue and on the optical mapping method that is used. A tissue region larger than the laser beam or collecting area of the array element contributes to the optical recordings.
引用
收藏
页码:1098 / 1107
页数:10
相关论文
共 20 条
[1]  
CHANCE B, 1965, BIOCHEM Z, V341, P357
[2]   OPTICAL MAPPING OF REPOLARIZATION AND REFRACTORINESS FROM INTACT HEARTS [J].
EFIMOV, IR ;
HUANG, DT ;
RENDT, JM ;
SALAMA, G .
CIRCULATION, 1994, 90 (03) :1469-1480
[3]   MONTE-CARLO MODELING OF LIGHT-PROPAGATION IN HIGHLY SCATTERING TISSUES .1. MODEL PREDICTIONS AND COMPARISON WITH DIFFUSION-THEORY [J].
FLOCK, ST ;
PATTERSON, MS ;
WILSON, BC ;
WYMAN, DR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (12) :1162-1168
[4]   MONTE-CARLO MODELING OF LIGHT-PROPAGATION IN HIGHLY SCATTERING TISSUES .2. COMPARISON WITH MEASUREMENTS IN PHANTOMS [J].
FLOCK, ST ;
WILSON, BC ;
PATTERSON, MS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (12) :1169-1173
[5]   SPECTRA, MEMBRANE-BINDING, AND POTENTIOMETRIC RESPONSES OF NEW CHARGE SHIFT PROBES [J].
FLUHLER, E ;
BURNHAM, VG ;
LOEW, LM .
BIOCHEMISTRY, 1985, 24 (21) :5749-5755
[6]  
GRAY RA, 1995, SCIENCE, V270, P1222, DOI 10.1126/science.270.5239.1222
[7]  
HAUGLAND RP, 1996, HDB FLUORESCENT PROB, P516
[8]  
Jacques SL, 1998, PHOTOCHEM PHOTOBIOL, V67, P23
[9]   Errors caused by combination of Di-4 ANEPPS and Fluo3/4 for simultaneous measurements of transmembrane potentials and intracellular calcium [J].
Johnson, PL ;
Smith, W ;
Baynham, TC ;
Knisley, SB .
ANNALS OF BIOMEDICAL ENGINEERING, 1999, 27 (04) :563-571
[10]   TRANSMEMBRANE VOLTAGE CHANGES DURING UNIPOLAR STIMULATION OF RABBIT VENTRICLE [J].
KNISLEY, SB .
CIRCULATION RESEARCH, 1995, 77 (06) :1229-1239